Registers refreshed 2026-11-20.See refresh dates
China

Shenzhen CTA Testing Technology Co.,

Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, People's Republic of China, Shenzhen, China

Visit website
A2LA 6534.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
22
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 22 standard numbers and the 16 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series7
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
EN6
EN 50364
EN 50383
EN 50384
EN 50385
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
CISPR3
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national

National versions in the same scope

AS/NZS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55015, IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

IEC3
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)

Certificate says EN 62311. Probably the same standard; not checked against the EN document.

IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national

National versions in the same scope

AS/NZS 62368.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
FCC PART 15Radio Frequency Devices

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

6534.01

The scope document we hold says it is valid until 2027-11-30.

View scope

Accredited scope, certificate 6534.01

LineMethodMatrixRange
1CFR 47, FCC Part 15 Subpart B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using MP 5:1986); CISPR 32; EN 55032; AS/NZS CISPR 32; BS EN 55032; CISPR 15; BS EN 55015; EN IEC 55015; AS/NZS CISPR 15; ICES-003; IEC 61000-3-2; EN IEC 61000-3-2; IEC 61000-3-3; EN 61000-3-3; CFR 47, FCC Part 18 (using MP-5:1986); CISPR 11; EN 55011; AS CISPR 11; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; IEC 61000-4-6; EN 61000-4-6; IEC 61000-4-11; EN 61000-4-11-to 40 GHz
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6534.01) Revised 11/06/2025 Page 2 of 5 Test Technology: Test Method(s) 1: Product Family Standards and Industry Specific Standards (excluding Radiated Immunity Testing per IEC/EN 61000-4-3 and Power Frequency Magnetic Field per IEC/EN 61000-4-8) CISPR 35; EN 55035; BS EN 55035; BS EN 61547; EN 61547; ETSI EN 301 489-1; ETSI EN 301 489-2; ETSI EN 301 489-3; ETSI EN 301 489-4; ETSI EN 301 489-5; ETSI EN 301 489-6; ETSI EN 301 489-9; ETSI EN 301 489-13; ETSI EN 301 489-15; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-22; ETSI EN 301 489-27; ETSI EN 301 489-28; ETSI EN 301 489-29; ETSI EN 301 489-31; ETSI EN 301 489-33; ETSI EN 301 489-34; ETSI EN 301 489-35; ETSI EN 301 489-50; ETSI EN 301 489-52 (5G NR excluded); ETSI EN 301 489-53; ETSI EN 301 843-1; ETSI EN 301 843-2; ETSI EN 301 843-4; ETSI EN 301 843-5; ETSI EN 301 843-6; ETSI EN 301 843-7 Radio Communications ANSI C63.10-2020 +Cor.1-2023 +C63.10a-2024 +Errata to C63.10a:2024 US / FCC CFR 47 FCC Part 15C (using ANSI C63.10-2020); CFR 47 FCC Part 15E (using ANSI C63.10-2020 and FCC KDB 905462 D02 (v02)); CFR 47 FCC Part 2, 22, 24, 25, 27, 30, 73, 74, 90, 95, 96, 97, and 101 (using ANSI C63.26:2015, ANSI/TIA-603-E:2016, and TIA-102.CAAA-E); ANSI C63.10; ANSI C63.26 Canada / ISED RSS-GEN; RSS-111; RSS-112; RSS-119; RSS-123; RSS-125; RSS-127; RSS-130; RSS-131; RSS-132; RSS-133; RSS-134; RSS-135; RSS-137; RSS-139; RSS-140; RSS-141; RSS-142; RSS-182; RSS-192; RSS-194; RSS-195; RSS-199; RSS-210; RSS-215; RSS-216; RSS-236; RSS-247; RSS-248; RSS-310 EU (excluding protocol conformance testing) ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 330; ETSI EN 300 422-2; ETSI EN 300 440; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 300 113; ETSI EN 300 086; ETSI EN 300 296; ETSI EN 300 219; ETSI EN 302 208; ETSI EN 302 502; ETSI EN 303 345-1; ETSI EN 303 345-2; ETSI EN 303 345-3; ETSI EN 303 345-4; ETSI EN 303 345-5; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 303 609; ETSI EN 301 511; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-11; ETSI EN 301 908-13; ETSI EN 301 908-15; ETSI EN 300 422-1; ETSI EN 303 687 Australia AS/NZS 4268
3IEEE C95.3; IEC 62479; IEC 62311; EN 62479; BS EN 62479; EN IEC 62311; EN 50383; BS EN 50383; EN 50385; BS EN 50385; EN 50364; BS EN 50364; EN 50663; BS EN 50663; EN 50665; BS EN 50665; EN 50384; BS EN 50384; IEEE/ANSI C95.1; KDB 447498 D01; KDB 447498 D02; AS/NZS 2772.2; Radiation Protection Series Publication No. 3; Radiation Protection Series S-1 (Rev. 1); IEC 62368-1; EN IEC 62368-1; AS/NZS 62368.1; UL 62368-1; BS EN 62368-1; Japan MIC Article 2-1 Item (8); MIC Article 2-1 Item (19); MIC Article 2-1 Item (19)-2; MIC Article 2-1 Item (19)-2-2; MIC Article 2-1 Item (19)-2-3; MIC Article 2-1 Item (19)-3; MIC Article 2 Paragraph 1 of Item 11‐3; Article 2 Paragraph 1 of Item 11‐4; Article 2 Paragraph 1 of Item 11‐7; Article 2 Paragraph 1 of Item 11‐8; Article 2 Paragraph 1 of Item 11‐19; Article 2 Paragraph 1 of Item 11‐21; Article 2 Paragraph 1 of Item 54--
4ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10-2020; FCC KDB 905462 D02 (v02)-to 40000 MHz
5ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015-to 40000 MHz
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SHENZHEN CTA TESTING TECHNOLOGY CO., LTD. Shenzhen, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 4th day of November 4, 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6534.01 Valid to November 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.