Aptiv
Champion Technical Center, 4551 Research Parkway, 44483, Warren, OH, United States
Visit website- Accredited standards
- 12
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 12 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO4
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
Other standards4
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM D4728
GMW3172
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
ISO 10605 (2001, 2008, 2023); GMW3097 (June 2015, March 2019, Dec 2022, Feb 2024, May 2025); CISPR 25 (2016, 2021); CISPR 25 (2002, 2008); DEF STAN 59-411 Part 3, Amdt. 1; DRE02.B (2008); ISO 11452-2 (2004, 2019); ISO 11452-4 (2005, 2011, 2020); ISO 7637-2 (2004, 2011); ISO 16750-2 (2012, 2023); ISO 7637-3 (2007, 2016)
ISO 11452-9 (2012, 2021); GMW3097 (June 2015, March 2019, Dec 2022, Feb 2024, May 2025), Section 3.4.4; ISO 11452-8 (2007, 2015); GMW3097 (June 2015, March 2019, Dec 2022, Feb 2024, May 2025), Section 3.4.5; DEF STAN 59-411 Part 3, Amdt. 1, B.17; DRS01.B (2008)
ASTM D4728-01; GMW3172; SAE/USCAR-2; Q-1000-207; GM 9123P; SAE J2030; TSC-1000G; GMW3191; USCAR20; ASTM B117; IEC 60068-2-52; USCAR21
Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active1913.01
The scope document we hold says it is valid until 2028-03-31.
Accredited scope, certificate 1913.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 10605 (2001, 2008, 2023); GMW3097 (June 2015, March 2019, Dec 2022, Feb 2024, May 2025); CISPR 25 (2016, 2021); CISPR 25 (2002, 2008); DEF STAN 59-411 Part 3, Amdt. 1; DRE02.B (2008); ISO 11452-2 (2004, 2019); ISO 11452-4 (2005, 2011, 2020); ISO 7637-2 (2004, 2011); ISO 16750-2 (2012, 2023); ISO 7637-3 (2007, 2016) | - | - |
| 2 | ISO 11452-9 (2012, 2021); GMW3097 (June 2015, March 2019, Dec 2022, Feb 2024, May 2025), Section 3.4.4; ISO 11452-8 (2007, 2015); GMW3097 (June 2015, March 2019, Dec 2022, Feb 2024, May 2025), Section 3.4.5; DEF STAN 59-411 Part 3, Amdt. 1, B.17; DRS01.B (2008) | - | - |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active1913.02
The scope document we hold says it is valid until 2028-03-31.
Accredited scope, certificate 1913.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | SAE/USCAR-2; Q-1000-101; GM 9123P (1999, Inactive 20083); GMW3191; SAE J2030; TSC-1000G; USCAR20; USCAR21; Q-1000-105; Q-1000-106; Q-1000-112; Q-1000-114; Q-1000-209; Q-1000-210; Q-1000-211; GM 9100P (1996, Inactive 20083) | automotive mechanical | - |
| 2 | ASTM D4728-01; GMW3172; SAE/USCAR-2; Q-1000-207; GM 9123P; SAE J2030; TSC-1000G; GMW3191; USCAR20; ASTM B117; IEC 60068-2-52; USCAR21 | - | -55 to 300 °C |
| 3 | EANW-4.4-PE-CSE-01.28 | - | - |
| 4 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Champion Technical Center, 4551 Research Parkway, Warren, OH, 44483, US
39.42040, -84.18090
Open in MapsLabs with overlapping accredited scope in United States
- Auto Technology CompanyStrongsville, OH · ~290 kmA2LAShares 1 accredited test methodGMW3172
- DEKRA CertificationPlymouth, MI · ~334 kmA2LAShares 1 accredited test methodGMW3172
- Element Materials Technology Detroit – Warren 11 MileWarren, MI · ~356 kmA2LAShares 1 accredited test methodGMW3172
- MGA Research CorporationTroy, MI · ~365 kmA2LAShares 1 accredited test methodGMW3172
- TUV SUD America - Auburn HillsAuburn Hills, MI · ~372 kmA2LAShares 1 accredited test methodGMW3172
Accreditation data refreshed from the A2LA register on .