Registers refreshed 2026-11-08.See refresh dates
South Korea

KSC Co.,

1106, Cheoinseong-ro, Namsa-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Yongin, 17115, South Korea, Yongin, South Korea

Visit website
A2LA 4956.02A2LA 4956.03ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
59
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 59 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60079 series22
IEC 60079-0+1 national

National versions in the same scope

KS C IEC 60079-0probably the same standard; matched by number only

IEC 60079-1+1 national

National versions in the same scope

KS C IEC 60079-1probably the same standard; matched by number only

IEC 60079-2+1 national

National versions in the same scope

KS C IEC 60079-2probably the same standard; matched by number only

IEC 60079-5+1 national

National versions in the same scope

KS C IEC 60079-5probably the same standard; matched by number only

IEC 60079-6+1 national

National versions in the same scope

KS C IEC 60079-6probably the same standard; matched by number only

IEC 60079-7+1 national

National versions in the same scope

KS C IEC 60079-7probably the same standard; matched by number only

IEC 60079-11+1 national

National versions in the same scope

KS C IEC 60079-11probably the same standard; matched by number only

IEC 60079-13
IEC 60079-15+1 national

National versions in the same scope

KS C IEC 60079-15probably the same standard; matched by number only

IEC 60079-18+1 national

National versions in the same scope

KS C IEC 60079-18probably the same standard; matched by number only

IEC 60079-25
IEC 60079-26
Show all 22
IEC 60079-27
IEC 60079-28+1 national

National versions in the same scope

KS C IEC 60079-28probably the same standard; matched by number only

IEC 60079-29-1
IEC 60079-29-4
IEC 60079-30-1
IEC 60079-31+1 national

National versions in the same scope

KS C IEC 60079-31probably the same standard; matched by number only

IEC 60079-32-2
IEC 60079-33
IEC 60079-35-1
IEC 60079-35-2
EN14
EN 1127-1
EN 1127-2
EN 1755
EN 4003
EN 13012
EN 13616-1
EN 13616-2
EN 13760
EN 14678-1
EN 14986
EN 50104
EN 50176
EN 50223
EN 50303
IEC6
IEC 60034-1
IEC 60034-5
IEC 60529Degrees of protection provided by enclosures (IP Code)+1 national

National versions in the same scope

KS C IEC 60529probably the same standard; matched by number only

IEC 62395-1
IEC 62444
IEC 62784
EN 13617 series4
EN 13617-1
EN 13617-2
EN 13617-3
EN 13617-4
ISO4
ISO 2738Sintered metal materials, excluding hardmetals - Permeable sintered metal materials - Determination of density, oil content and open porosity
ISO 4003Permeable sintered metal materials - Determination of bubble test pore size
ISO 16582Open end blind rivets with break pull mandrel and protruding head - Cu/St or Cu/Br or Cu/SSt
ISO 16852Flame arresters - Performance requirements, test methods and limits for use
EN 1834 series3
EN 1834-1
EN 1834-2
EN 1834-3
EN 50050 series3
EN 50050-1
EN 50050-2
EN 50050-3
ISO 80079 series3
ISO 80079-36Explosive atmospheres - Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements
ISO 80079-37Explosive atmospheres - Part 37: Non-electrical equipment for explosive atmospheres - Non-electrical type of protection constructional safety ''c'', control of ignition sources ''b'', liquid immersion ''k''
ISO/IEC 80079-38Explosive atmospheres - Part 38: Equipment and components in explosive atmospheres in underground mines

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

4956.02

The scope document we hold says it was valid until 2026-09-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 4956.02

LineMethodMatrixRange
1IEC 60079-0 Edition 7.0; EN IEC 60079-0:2018; EN 60079-0:2012; UL 60079-0 Edition 7.0; CAN/CSA C22.2 NO 60079-0:19; KS C IEC 60079-0:2017; IEC 60079-1 Edition 7.0; EN 60079-1:2014; EN 60079-2:2014/AC:2015; UL 60079-1 Edition 7.0; CAN/CSA C 22.2 NO 60079-1:16; KS C IEC 60079-1:2014; IEC 60079-2 Edition 6.0; EN 60079-2:2014; UL 60079-2 Edition 6.0; CAN/CSA C22.2 NO 60079-2:16; KS C IEC 60079-2:2014; IEC 60079-5 Edition 4.1; EN 60079-5:2015; UL 60079-5 Edition 4.0; CAN/CSA C22.2 NO 60079-5:19; KS C IEC 60079-5:2015; IEC 60079-6 Edition 4.1; EN 60079-6:2015; UL 60079-6 Edition 4.0--
2CAN/CSA C22.2 NO 60079-6:17; KS C IEC 60079-6:2015; IEC 60079-7 Edition 5.1; EN IEC 60079-7:2015+A1:2018; UL 60079-7 Edition 5.0; CAN/CSA C22.2 NO 60079-7:16; KS C IEC 60079-7:2015; IEC 60079-11 Edition 7.0; EN 60079-11:2012; UL 60079-11 Edition 6.0; CAN/CSA C22.2 NO 60079-11:14; KS C IEC 60079-11:2011; IEC 60079-13 Edition 2.0; EN 60079-13:2017; IEC 60079-15 Edition 5.0; EN IEC 60079-15:2019; EN 60079-15:2010; UL 60079-15 Edition 5.0; CAN/CSA C22.2 NO 60079-15:18; KS C IEC 60079-15:2017; IEC 60079-18 Edition 4.1; EN 60079-18:2015+A1:2017; UL 60079-18 Edition 4.0; CAN/CSA C22.2 NO 60079-18:16; KS C IEC 60079-18:2014; IEC 60079-25 Edition 3.0; EN 60079-25:2010+AC:2013; UL 60079-25 Edition 2.0; CAN/CSA C22.2 NO 60079-25:14; IEC 60079-26 Edition 4.0; EN 60079-26:2015; UL 60079-26 Edition 3.0; CAN/CSA C22.2 NO 60079-26:16; IEC 60079-27 Edition 2.0; IEC 60079-28 Edition 2.0; EN 60079-28:2015; UL 60079-28 Ed. 2.0; CAN/CSA C22.2 NO 60079-28:16; KS C IEC 60079-28:2006--
3IEC 60079-29-1 Edition 2.1; EN 60079-29-1:2016; EN 60079-29-1:2016+A11:2022; EN 60079-29-1:2016+A1:2022; UL 60079-29-1 Ed. 2.0; CAN/CSA C22.2 NO 60079-29-1:17; IEC 60079-29-4 Edition 1.0; EN 60079-29-4:2010; UL 60079-29-4 Ed. 1.0; CAN/CSA C22.2 NO 60079-29-4:16; IEC/IEEE 60079-30-1 Edition 1.0; EN 60079-30-1:2017; UL 60079-30-1 Ed. 1.0; CAN/CSA C22.2 NO 60079-30-1:17; IEC 60079-31 Edition 3.0; EN 60079-31:2014; UL 60079-31 Ed. 2.0; CAN/CSA C22.2 NO 60079-31:15; KS C IEC 60079-31:2013; IEC TS 60079-32-1 Edition 1.1; PD CLC/TR 60079-32-1:2018; IEC 60079-32-2 Edition 1.0; EN 60079-32-2:2015; IEC 60079-33 Edition 1.0; PD CLC/TR 60079-33:2015; IEC 60079-35-1 Edition 1.0; EN 60079-35-1:2011; EN 60079-35-1:2011+AC:2011; IEC 60079-35-2 Edition 1.0; EN 60079-35-2:2012; ISO 80079-36 Edition 1.0; EN ISO 80079-36:2016; ISO 80079-37 Edition 1.0; EN ISO 80079-37:2016--
4IEC TS 60079-39 Edition 1.0; PD CLC IEC/TS 60079-39:2019; IEC TS 60079-40 Edition 1.0; PD IEC/TS 60079-40:2015; IEC TS 60079-46 Edition 1.0; PD IEC/TS 60079-46:2015; IEC 60529:2013 Edition 2.2; EN 60529:2013; KS C IEC 60529:2013; NEMA 250-2020; IEC 62784:2017 Ed. 1.0; EN 62784:2018; ISO 4003:1977; EN 4003:2006; EN 1127-1:2019; EN 1127-1:2011; EN 1127-2:2014; EN 50050-1:2013; EN 50050-2:2013; EN 50050-3:2013; ISO 2738:1999-to 1000 V
5EN ISO/IEC 80079-38:2016; ISO/IEC 80079-38:2016; EN 50303:2000; EN 14986:2017; EN 1834-1:2000; EN 1834-2:2000; EN 1834-3:2000; EN 60034-1:2010; IEC 60034-1:2022; IEC 60034-5:2020; EN IEC 60034-5:2020; EN 50104:2019; EN 13012:2021; EN 13616-1:2016; EN 13616-2:2016--
6EN 13617-1:2021; EN 13617-2:2021; EN 13617-3:2021; EN 13617-4:2021; EN 13760:2021; EN 14678-1:2013; EN 14986:2017; EN 50176:2009; EN 50223:2015; IEC 62395-1:2013; EN 62395-1:2013; IEC 62444:2010; EN 62444:2013; EN 1755:2015; ISO 16582:2016; EN ISO 16852:2016--
7

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited KSC CO., LTD. Yongin, South Korea for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 11th day of July 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 4956.02 Valid to September 30, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

4956.03

Accredited scope, certificate 4956.03

No scope items available

Location

1106, Cheoinseong-ro, Namsa-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Yongin, 17115, South Korea, Yongin, KR

37.24057, 127.17856

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.