Registers refreshed 2026-11-20.See refresh dates
Mexico

GST Manufacturas de México S.A. de C.V. (PANGEA Leon)

Boulevard Hermanos Aldama, 4312, León, Guanajuato, 37490, Mexico, León, Guanajuato, Mexico

Visit website

No active accreditation in the register.

Register refreshed 2026-11-20

We check which accredited labs can do it and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Withdrawn

2620.01

View scope

Accredited scope, certificate 2620.01

LineMethodMatrixRange
1ISO 3376; ASTM D2208; GMW3010; TSL 5101G; MS 300-31; NES M0602; ISO 13934-1; 8102Z-SZN-A320; 8102Z-TJB-A000; ASTM D5034; ISO 3377-1; ISO 13937-2; ASTM D5733; ISO 23910; ISO 2589; ASTM D1813; ISO 17186Automotive Leather-
2GMW3182; MS 300-31 (Sec. 4.1) 1; NES M0602 (Sec. 7) 1; ISO 2420; ASTM D3776/D3776M; TSL 5101G (Sec. 3.1) 1; GMW3211; 8102Z-SZN-A320 (Sec.6-1-6) 1; 8102Z-TJB-A000 (Sec. 6-1-6) 1; MS 300-31 (Sec. 4.8) 1; NES M0602 (Sec. 15) 1; PV 3909; SAE J855; TSL 5101G (Sec. 3.31) 1; GMW3208; MS 300-31 (Section 4.19) 1; NES M0602 (Section 19.2) 1; ISO 17076-1; 8102Z-SZN-A320 (Sec.6-2-6-2-2) 1; 8102Z-TJB-A000 (Sec. 6-2-6-2-2) 1; MS 300-31 (Sec. 4.40)1; TSL 5101G (Sec. 3.8.2 Method B) 1; NES M0602 (Section 20)1; 8102Z-SZN-A320 (Sec. 6-2-6-2-3) 1; 8102Z-TJB-A000 (Sec. 6-2-6-2-3) 1; NES M0602 (Section 19.1)1; NES M0602 (Section 19.3)1; NES M0602 (Section 19.4)1; ISO 17076-2; AA-0412; VDA 230-211; LP-463KB-06-01; NES M0602 (Section 21) 1; NES M0602 (Section 22) 1; NES M0602 (Section 23) 1; 8102Z-SZN-A320 (Sec. 6-2-5-2-1) 1; 8102Z-TJB-A000 (Sec. 6-2-5-2-1) 1; 8102Z-SZN-A320 (Sec. 6-2-5-2-2) 1; 8102Z-TJB-A000 (Sec. 6-2-5-2-2) 1; MS 300-31 (Sec. 4.12.3) 1; MS 300-31 (Sec. 4.12.4) 1; ISO 105-X12; AATCC 8; SAE J861; TSL 5101G (Sec. 3.19.2) 1; ISO 11640; LP-463KC-21-01; MS 300-31 (Sec.4.28)1; NES M0602 (Sec. 34)1; TSL 5101G (Sec. 3.28) 1--
3ISO 11644; 8102Z-SZN-A320 (Sec. 6-2-12) 1; 8102Z-TJB-A000 (Sec. 6-2-12) 1; GMW3220; LP.7M008, Method A (LP-463LB-10-01); MS715-73 (Sec. 4.2) 1; MS715-73 (Sec. 4.3) 1; MS715-73 (Sec. 4.5) 1; MS715-73 (Sec. 4.6) 1; MS715-73 (Sec. 4.9) 1; MS715-73 (Sec. 4.10) 1; MS715-73 (Sec. 4.11) 1; AA-0496; ISO 15701; TL 52064 (Section 6.5) 1; GMW14102; AA-0420; LP-463LB-11-02; GMW14132; 8102Z-SZN-A320 (Sec. 6-2-4) 1; 8102Z-TJB-A000 (Sec. 6-2-4) 1; MS 300-31 (Sec. 4.13) 1; TSL 5101G (Sec. 3.16) 1; ISO 5402 (Withdrawn); GMW3262 (Sec. 3.2.13.2)1 ; GMW3262 (Sec. 3.2.13.3)1 ; ISO 5402-1; ASTM D6182; AA-0563; MS 300-31 (Sec. 4.35) 1; ASTM D2097; TSL 5101G (Sec. 3.14.2) 1; MS 300-31 (Sec. 4.14) 1; GMW14126; GMW14127; 8102Z-SZN-A320 (Sec. 6-2-2) 1; 8102Z-TJB-A000 (Sec. 6-2-2) 1; NES M0602 (Sec. 31.2.1)1; LP-463KB-28-01 (Method B); TSL 5101G (Sec. 3.15) 1; ISO 17228; 8102Z-SZN-A320 (Sec. 6-1-7) 1; 8102Z-TJB-A000 (Sec. 6-1-7) 1; 8102Z-SZN-A320 (Sec. 6-2-9) 1; 8102Z-TJB-A000 (Sec. 6-2-9) 1; TL 52064 (Sec 6.6) 1; TL 52064 (Sec. 12) 1; TL 52064 (Sec. 12.1) 1; TL 52064 (Sec. 5.12) (Sec. 12.2) 1; TL 52064 (Sec. 17.4) 1; LP-463LB-13-01; TSL 5101G (Sec. 3.23) 1; AATCC EP 1; AATCC EP 2; AATCC EP 6; ISO 105-A02; ISO 105-A03; ISO 105-A04; ISO 105-A05; ASTM E1331; JIS L0804; JIS L0805--
4GMW3390; 8102Z-SZN-A320; 8102Z-TJB-A000; NES M0602; MS 300-31; ASTM D1388; TSL 5101G; ISO 17235; GMW14134; DIN 75200; FMVSS 302; GB 8410; GMW3232; MS 300-08; NES M0094; TL 1010; HES D6003; GS 97038; DBL 5307; ISO 3795; MS-JP-9-4; TSM0500G; GMW3205; PV 3900; VDA 270; CS-13398; ISO 105-E04; AA-0567; ISO 11641; GMW3405; MS.50019; GMW14124; GMW3262; PV 1200; TL 52064; AA-0565; AA-0568; LP-463LB-12-01Materials-
5ISO 2813; ASTM D523; GMW3235 - Method A; SAE J1756 (Photometric Procedure); PV 3015; DIN 75201-B; DIN 75201-A; GMW3235 - Method B; SAE J1756 (Gravimetric Procedure); MS.50066, Method A (LP-463DB-12-01); 8102Z-SZN-A320 (Sec. 6-3-3) 1; 8102Z-TJB-A000 (Sec. 6-3-4) 1; MS 300-54; TSM0503G; VDA 230-205; LP-463KB-24-01; 8102Z-TJB-A000 (Sec. 6-3-7) 1; TSL 5101G (Sec. 3.42) 1; LP-463LB-05-01; MS 322-04 (Sec. 4.2)1; GMW3259; ISO 9237; TSL 2107G (Sec 4.1) 1; 8102Z-SZN-A320 (Sec. 6-2-15) 1; 8102Z-TJB-A000 (Sec. 6-2-15) 1; GMW3221; ISO 2419; VW 50554; ASTM D1610; ASTM D6657; DIN EN ISO 4045 (ISO 4045); ASTM D7477; ISO 3380; ASTM D6658; 8102Z-SZN-A320 (6-3-2)1; 8102Z-TJB-A000 (Sec. 6-3-3) 1; PR362; ISO 4048; 8102Z-SZN-A320 (Sec. 6-3-2) 1; 8102Z-TJB-A000 (Sec. 6-3-2) 1; AA-0410; LP-263KC-04-02; LP-463KC-04-03; MS 300-31 (Sec. 4.33)1; GMW 15377; 8102Z-SZN-A320 (Sec. 6.2.14)1; 8102Z-TJB-A000 (Sec. 6.2.17)1; PV 3968; TSL 5101G (Sec. 3.34) 1--
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited GST MANUFACTURAS DE MÉXICO S.A. DE C.V. (PANGEA LEON) León, Guanajuato, Mexico for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 8th day of November 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2620.01 Valid to July 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Boulevard Hermanos Aldama, 4312, León, Guanajuato, 37490, Mexico, León, Guanajuato, MX

21.12196, -101.68298

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.