Analytik Aurachtal
Wirtshöhe 6, 91086, Aurachtal, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Analytik Aurachtal?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-19056-01-01Active
- D-PL-19056-01-02Active
- D-PL-19056-01-03Withdrawn
- D-PL-19056-01-00Active
Accredited standards
4Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 62321-3-1Name not checked yet
DIN EN 62321-3-1; DIN EN 62321-7-1; AHV409001aur; AHV770050aur; AHV790001aur
IEC 62321-7-1Name not checked yet
DIN EN 62321-3-1; DIN EN 62321-7-1; AHV409001aur; AHV770050aur; AHV790001aur
ISO 16000-3Indoor air - Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air - Active sampling method
DIN ISO 16000-3; DIN ISO 16000-6; VDI 2464 Blatt 1; AHV409001aur; AHV750002aur; AHV770010aur; AHV770050aur
ISO 16000-6Indoor air - Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in indoor and test chamber air by active sampling on sorbent tubes, thermal desorption and gas chromatography using MS or MS FID
DIN ISO 16000-3; DIN ISO 16000-6; VDI 2464 Blatt 1; AHV409001aur; AHV750002aur; AHV770010aur; AHV770050aur
Scope as published by DAKKS
7 lines
ISO/IEC 17025
ActiveD-PL-19056-01-01
Accredited scope, certificate D-PL-19056-01-01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | Ambient air | - |
| 2 | chemical | DIN ISO 16000-3; DIN ISO 16000-6; VDI 2464 Blatt 1; AHV409001aur; AHV750002aur; AHV770010aur; AHV770050aur | Ambient air | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-19056-01-02
Accredited scope, certificate D-PL-19056-01-02
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | materials | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | Elektro- und Elektronikgeräten; metallhaltigen und kunststoffhaltigen Werkstoffen | - |
| 2 | materials | DIN EN 62321-3-1; DIN EN 62321-7-1; AHV409001aur; AHV770050aur; AHV790001aur | Produkten der Elektrotechnik; farblosen und farbigen Korrosionsschutzüberzügen auf Metallen; technischen Bauteilen, Oberflächen, Rückständen, Werkstoffen und Baustoffen; metallischen, nichtmetallischen oder viskosen Materialien | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
WithdrawnD-PL-19056-01-03
Accredited scope, certificate D-PL-19056-01-03
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | materials | - | Bauteilen und Komponenten | - |
| 2 | materials | ISO 16232; VDA 19 Teil 1 | Komponenten für Fluidsysteme; Partikelverunreinigungen funktionsrelevanter Automobilteile | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-19056-01-00
Accredited scope, certificate D-PL-19056-01-00
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | - | DIN EN ISO/IEC 17025:2018; DIN EN ISO/IEC 17011; DIN EN ISO 9001 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- Analytik Institut Rietzler GmbH Laborstandort und Emissionsmessstelle FürthFürth · ~15 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Ambient air
- anbus analytikFürth in Bayern · ~18 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Ambient air
- CompetenzaFürth · ~18 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Ambient air
- EMCCons Dr. RASEK GmbH & Co. KGEbermannstadt · ~38 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Ambient air
- RoodMicrotec GmbH Abt. QTAL Qualification & ReliabilityNördlingen · ~83 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Ambient air
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.