MRM Metrology
Brampton, Canada
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at MRM Metrology?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 4194.01Active
Accredited standards
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Scope as published by A2LA
8 lines
ISO/IEC 17025
Active4194.01
The scope document we hold says it is valid until 2026-10-31.
Accredited scope, certificate 4194.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | dimensional | - | - | 0.001 to 1000 mm |
| 2 | dimensional | - | - | 0.01 to 360 m; mm; ° |
| 3 | dimensional; mechanical | - | - | 0.01 to 1000 mm; °; in/min; g; kg |
| 4 | dimensional | NIST handbook 105-1 | Class F Weights (Pounds); Class F Weights (Ounces) | 0.0001 to 70 lb; oz |
| 5 | mechanical | - | - | 1 to 35 kg |
| 6 | mechanical | - | - | to 200 lbf |
| 7 | dimensional; mechanical | (A2LA Cert. No. 4194.01) 06/03/2025 Page 7 of 7
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This laboratory offers commercial dimensional testing/calibration service.
5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration.
6 Test Stands are calibrated for both Distance under the Dimensional portion of the Scope of Accreditation
and Force under the Mechanical portion of the Scope of Accreditation.
7 In the statement of CMC, L is the length of tape measure in meters.
8 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 8 | - | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
2 other sites in this organization
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.