Vitesco Automotive Changchun Co., Ltd. Vitesco Technologies Laboratory Changchun
No. 2177 Changde Rd, Er Dao District, Changchun, 130000, People's Republic of China, Changchun, China
- Accredited standards
- 30
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 30 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068 series14
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-18
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60068-2-67
IEC 60068-2-75
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ISO6
ISO 2248Packaging - Complete, filled transport packages - Vertical impact test by dropping
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ISO 16750 series3
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
Other standards3
DIN 40050-9-1
IEC 68-2-68
IEC 60529Degrees of protection provided by enclosures (IP Code)
GB/T 2423.1; ISO 16750-4, Sec. 5.1.1; IEC 60068-2-1; JASO D 001, Sec. 5.12; VW 80000: Sec. 5.6.1; GMW 3172: Sec. 8.4.2; GB/T 2423.1; ISO 16750-4: Sec. 5.1.1; IEC 60068-2-1; JASO D 001: Sec. 5.13; VW 80000: Sec. 5.6.3; GMW 3172: Sec. 8.4.2; GB/T 2423.2; ISO 16750-4: Sec. 5.1.2; IEC 60068-2-2; JASO D 001: Sec. 5.14; VW 80000: Sec. 5.6.1; GMW 3172: Sec. 9.4.1; GB/T 2423.2; ISO 16750-4: Sec. 5.1.2; IEC 60068-2-2; JASO D 001: Sec. 5.15; VW 80000: Sec. 5.8.2; GMW 3172: Sec. 9.4.1
GB/T 2423.3; GB/T 2423.50; IEC 60068-2-78; JASO D 001: Sec. 5.19; IEC 60068-2-67; VW 80000: Sec. 5.6.14; GMW 3172: Sec. 9.4.6; ISO 16750-4: Sec. 5.6; IEC 60068-2-38; GB/T 2423.4; IEC 60068-2-30; GB/T2423.34; JASO D 001: Sec. 5.18; VW 80000: Sec. 5.6.8; GMW 3172: Sec. 9.4.5; GB/T 2423.22; ISO16750-4: Sec. 5.3.1; JASO D 001: Sec. 5.16; IEC 60068-2-14; VW 80000: Sec. 5.8.3; GMW 3172: Sec. 9.4.3; GB/T 2423.22; ISO 16750-4: Sec. 5.3.2; JASO D 001: Sec. 5.17; IEC 60068-2-14; VW 80000: Sec. 5.6.5; GMW 3172: Sec. 9.4.2; ISO 16750-4: Sec. 5.2; VW 80000: Sec. 5.6.2; IEC 60068-2-2: Sec. 5.2; JASO D 001: Sec. 5.20; GMW 3172: Sec. 8.4.3; ISO 16750-4: Sec. 5.4.3; VW 80000: Sec. 5.6.13; GMW 3172: Sec. 9.5.3; GMW 3172: Sec. 9.5.5; ISO 16750-4: Sec. 5.4.2; VW 80000: Sec. 5.6.12; GMW 3172: Sec. 9.4.4
GB/T 2423.35; ISO 16750-3: Sec.4 .1; GB/T 2423.10; IEC 60068-2-6; GB/T 2423.56; IEC 60068-2-64; JASO D 001: Sec. 5.23; JIS D 1601; VW 80000: Sec. 5.5.4; GMW 3172: Secs. 7.3.1, 9.3.1, and 10.3; GB/T 2423.7; GB/T 4857.5; ISO 16750-3: Sec. 4.3; ISO 2248; JASO D 001: Sec. 5.24; VW 80000 Sec. 5.5.1; GMW 3172: Sec. 9.3.10; IEC 60068-2-31: Sec. 7.2; GB/T 2423.17; ISO 9227; GB/T 10125; IEC 60068-2-11; VW80000: Secs. 5.6.6 and 5.6.7; GMW 3172: Sec. 9.4.7; DIN 40050-9-1: only for IPX7, IPX8, IPX9K; ISO 20653: only for IPX7, IPX8, IPX9K; IEC 60529: only for IPX7, IPX8, IPX9K; GB/T 2423.38: only for IPX7, IPX8, IPX9K; IEC 60068-2-18: only for IPX7, IPX8, IPX9K; VW 80000: Sec. 11.11, only for IPX7, IPX8, IPX9K; GMW3172: Secs. 9.5.2, 9.5.3, only for IPX7, IPX8, IPX9K; ISO 16750-4: Sec. 7, only for IPX7, IPX8, IPX9K; IEC 60068-2-75; GB/T 2423.55 (only Ehc); ISO 16750-4: Sec. 5.11; ISO 20653: Sec. 8.3; GB/T 30038; IEC 68-2-68; GB/T 2423.37; IEC 60529
ISO 16750-3: Secs. 4.2.1, 4.2.2; GB/T 28046.3: Sec 4.2; GB/T 2423.5; IEC 60068-2-27; VW 80000: Secs. 5.5.5, 5.5.6; GMW 3172: Secs. 9.3.2, 9.3.3, 9.3.4
ISO 16750-2 Sec. 4.6.4; VW 80000 Sec. 5.4.7; GMW 3097 Sec. 3.5.2; ISO 16750-2 Sec. 4.7; VW 80000 Sec. 5.4.17; GMW 3172 Sec. 8.2.2; JASO D 001 Sec. 5.4; ISO 16750-2 Sec. 4.8; VW 80000 Sec. 5.4.18; GMW 3172 Sec. 9.2.11; ISO 16750-2 Sec. 4.8; GMW 3172 Sec. 9.2.12; ISO 16750-2 Sec. 4.9; VW 80000 Sec. 7.14; GMW 3172 Secs. 9.2.9, 9.2.10; ISO 16750-2 Sec. 4.10; VW 80000 Sec. 5.4.19; GMW 3172 Secs. 9.2.6, 9.2.7, 9.2.8; ISO 16750-2 Sec. 4.3.1.2; VW 80000 Sec. 5.4.6; GMW 3172 Sec. 8.2.1; GMW 3172 Sec. 9.2.3; GMW 3172 Sec. 9.2.13; VW 80000 Sec. 5.4.12; VW 80000 Sec. 5.4.15; VW 80000 Sec. 5.4.16; VW 80000 Sec. 5.4.21; ISO 7637-2 Secs. 5.6.1, 5.6.2, 5.6.3; GM 3097 Sec. 3.5.2; TL 81000 Sec. 5.4; ISO 7637-3 Secs. 4.5 CCC 4.6 DCC, 4.7 ICC; GM 3097 Secs. 3.5.3, 3.5.4 , 3.5.5; TL 81000 Sec. 5.4.4
ISO 16750-2 Sec. 4.11; VW 80000 Sec. 5.4.22; ISO 16750-2 Sec. 4.12; VW 80000 Sec. 5.4.20; GMW 3172 Sec. 9.2.16; ISO 7637-2 Sec. 4.3; GMW 3097 Sec. 3.5.1; Ford EMC CS; TL 81000 Sec. 3.4.4.2; ISO 10605 Secs. 8 & 9; ISO 10605:2008; GB/T 19951 Secs. 8 & 9; JASO D001 Sec. 5.8; TL 81000 Sec. 5.1; GMW 3097 Sec. 3.6; GB/T 33014.4; ISO 11452-4 Sec. 6.1; GMW 3097 Sec. 3.4.1; FMC 1278 Sec. 12.5; TL 81000 Sec. 5.2.2; GS 95002 Sec. 7.2.3; GB/T 18655 Secs. 6.3, 6.4; CISPR 25 Secs. 6.3, 6.4; GMW 3097 Sec. 3.3.2; FMC 1278 Secs. 9 & 10; TL 81000 Sec. 5.3.5; GS 95002 Secs. 7.1.1.2.1, 7.1.1.2.2, 7.1.3; ISO 11452-8 Sec. 6.2; GMW 3097 Sec. 3.4.5; FMC 1278 Sec. 13.3.1; TL 81000 Sec. 5.2.6; ISO 11452-9; ISO 11452-9:2012; GMW 3097 Sec. 3.4.4; FMC 1278 Sec. 12.7; TL 81000 Sec. 5.2.5; GS 95002 Sec. 7.2.4.3; GB/T 18655 Sec. 6.5; CISPR 25 Sec. 6.5; GMW 3097 Sec. 3.3.1; FMC 1278 Sec. 8; TL 81000 Sec. 5.3.6; GS 95002 Sec. 7.1.4.2
GB/T 33014.2; ISO 11452-2; GMW 3097 Sec. 3.4.2; FMC 1278 Sec. 12.6 (No 300 V/m Pulse Modulated); TL 81000 Sec. 5.2.3 (No 300 Hz, 3μs Modulated); GS 95002 Sec. 7.2.4.2
ISO 16750-2 Sec. 4.3; VW 80000 Secs. 5.4.3, 5.4.4; GMW 3172 Sec. 8.2.3; JASO D 001 Secs. 5.5, 5.6; ISO 16750-2 Sec. 4.2; ISO 16750-2 Sec. 4.4; VW 80000 Sec. 5.4.8; GMW 3172 Sec. 9.2.4; ISO 16750-2 Sec. 4.5; VW 80000 Sec. 5.4.9; VW 80000 Sec. 5.4.10; ISO 16750-2 Sec. 4.6.1.1; VW 80000 Sec. 5.4.5; JASO D 001 Sec. 5.3; ISO 16750-2 Sec. 4.6.2; VW 80000 Sec. 5.4.11; GMW 3172 Sec. 9.2.2; ISO 16750-2 Sec. 4.6.3; VW 80000 Sec. 5.4.13; GMW 3172 Sec. 9.2.17
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-06.
Scope as published by A2LA
10 lines
ISO/IEC 17025
Active6235.03
The scope document we hold says it is valid until 2027-11-30.
ISO/IEC 17025
Active6235.04
The scope document we hold says it is valid until 2027-11-30.
Labs with overlapping accredited scope in China
- DEKRA Testing and Certification (Shanghai)ShanghaiA2LAShares 3 accredited test methodsIEC 60068-2-1IEC 60068-2-27ISO 11452-2
- DEKRA IST Reliability ServicesJiangsu Province, People’s Republic of ChinaA2LAShares 2 accredited test methodsIEC 60068-2-1IEC 60068-2-6
- Centre Testing International (Suzhou) Co.,Kunshan, JiangsuA2LAShares 1 accredited test methodISO 11452-9
- China Certification ICT Co., Ltd (DongGuan)DongguanA2LAShares 1 accredited test methodISO 11452-2
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 1 accredited test methodISO 11452-2
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.