Calibration Technologies
4157 Park Blvd, 40209, Louisville, KY, United States
- Scope lines
- 8
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 8 scope lines.
A2LA certificate 2810.01 · 8 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | to 6 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2810.01) 6/18/2025 Page 2 of 7
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage3 – Generate
(0 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
16 µV/V + 0.8 µV
9.1 µV/V + 1.7 µV
9.3 µV/V + 17 µV
14 µV/V + 0.12 mV
14 µV/V + 2.4 mV
Fluke 5522A
DC Voltage3 – Measure
(0 to 200) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
0.0025 % + 0.11 µV
3.5 µV/V + 0.60 µV
3.5 µV/V + 4.0 µV
5.8 µV/V + 38 µV
5.7 µV/V + 0.38 mV
Fluke 8508A
DC Current3 – Generate
(0 to 20) A Range
Clamp-On
(0 to 330) μA
(0 to 3.3) mA
(0 to 33) mA
(0 to 330) mA
(0 to 1.1) A
(1.1 to 3) A
(0 to 11) A
(11 to 20.5) A
(25 to 1000) A
0.012 % + 0.02 µA
78 µA/A + 5.8 mA
78 µA/A + 58 µA
78 µA/A + 0.6 mA
0.016 % + 6.0 mA
0.03 % + 6.0 mA
0.039 % + 0.4 A
0.078 % + 0.59 A
0.16 % + 12 mA
Fluke 5522A
Fluke 5522A with
50 turn coil
DC Current3 – Measure
(0 to 200) μA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
10 µA/A + 0.0005 µA
9 µA/A + 0.0074 µA
20 µA/A + 0.07 µA
50 µA/A + 1.3 µA
0.019 % + 16 µA
0.018 % + 0.84 mA
Fluke 8508A
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3 – Generate
(1 to 33) mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
0.062 % + 4.7 µV
0.012 % + 4.7 µV
0.016 % + 4.7 µV
Fluke 5522A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2810.01) 6/18/2025 Page 3 of 7
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3 – Generate
(cont)
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.078 % + 4.7 µV
0.09 % + 9.3 µV
0.21 % + 39 µV
0.024 % + 6.2 µV
0.012 % + 6.2 µV
0.013 % + 6.2 µV
0.028 % + 6.2 µV
0.062 % + 25 µV
0.16 % + 55 µV
0.07 % + 39 µV
0.012 % + 47 µV
0.015 % + 47 µV
0.024 % + 39 µV
0.055 % + 97 µV
0.2 % + 0.47 mV
0.024 % + 0.51 mV
0.012 % + 0.47 mV
0.019 % + 0.47 mV
0.028 % + 0.47 mV
0.07 % + 1.2 mV
0.068 % + 1.6 mV
0.062 % + 4.7 mV
0.064 % + 4.7 mV
0.065 % + 4.7 mV
0.17 % + 39 mV
0.024 % + 7.8 mV
0.02 % + 7.8 mV
0.024 % + 7.8 mV
Fluke 5522A
AC Voltage3 – Measure
Up to 200 mV
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
0.013 % + 29 µV
0.009 % + 22 µV
0.008 % + 17 µV
0.007 % + 15 µV
0.011 % + 12 µV
Fluke 8508A | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2810.01) 6/18/2025 Page 4 of 7
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3 – Measure
(cont)
Up to 200 mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
0.032 % + 15 µV
0.076 % + 23 µV
0.01 % + 0.4 mV
0.016 % + 29 µV
0.009 % + 22 µV
0.008 % + 22 µV
0.01 % + 68 µV
0.022 % + 48 µV
0.057 % + 0.2 mV
0.3 % + 2.0 mV
1.0 % + 20 mV
0.015 % + 1.2 mV
0.012 % + 0.22 mV
90 µV/V + 0.23 mV
80 µV/V + 0.22 mV
0.011 % + 0.25 mV
0.022 % + 0.41 mV
0.057 % + 2.0 mV
0.3 % + 20 mV
1.0 % + 0.2 V
0.015 % + 12 mV
80 µV/V + 13 mV
90 µV/V + 2.3 mV
80 µV/V + 2.2 mV
0.011 % + 2.3 mV
0.022 % + 4.0 mV
0.057 % + 20 mV
0.3 % + 0.2 V
1.0 % + 2.0 V
0.015 % + 70 mV
0.012 % + 20 mV
0.012 % + 20 mV
0.023 % + 40 mV
0.058 % + 0.2 V
Fluke 8508A | to 1000 V |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2810.01) 6/18/2025 Page 5 of 7
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance3 – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 1100) Ω
(1.1 to 11) kΩ
(11 to 110) kΩ
110 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
330 MΩ to 1.1 GΩ
31 µΩ/Ω + 1.2 mΩ
23 µΩ/Ω + 1.7 mΩ
22 µΩ/Ω + 1.6 mΩ
22 µΩ/Ω + 2.4 mΩ
22 µΩ/Ω + 24 mΩ
23 µΩ/Ω + 0.24 Ω
25 µΩ/Ω + 2.4 Ω
47 µΩ/Ω + 35 mΩ
0.011 % + 58 Ω
0.02 % + 2.9 kΩ
0.039 % + 3.5 kΩ
0.24 % + 0.12 MΩ
1.2 % + 0.58 MΩ
Fluke 5522A
Resistance3 – Measure
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
6.7 µΩ/Ω + 56 µΩ
6.0 µΩ/Ω + 0.16 mΩ
8.0 µΩ/Ω + 61 µΩ
0.001 % + 0.6 mΩ
0.001 % + 6.0 mΩ
0.001 % + 55 mΩ
0.001 % + 1.0 Ω
0.002 % + 0.14 kΩ
0.012 % + 13 kΩ
0.05 % + 8.3 MΩ
Fluke 8508A
III. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Torque Wrenches3
Up to 250 in·lbf
Up to 250 ft·lbf
(200 to 2000) ft·lbf
Up to 600 ft·lbf
0.6 %
0.6 %
0.7 %
0.36 %
AWS torque system
CDI torque system
Torque Analyzers
(50 to 250) in·lbf
(50 to 250) ft·lbf
0.1 % + 0.0016 in·lbf
0.3 % + 0.028 ft·lbf
Deadweight &
torque arms | ||
| 6 | NIST Class F; NIST Class S | Air | See scope document |
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2810.01) 6/18/2025 Page 7 of 7
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Tachometers3
(Non-Contact)
(0.5 to 99 999) rpm
0.0014 % + 0.59 rpm
Generate frequency
to light using Fluke
5522A & LED as
source.
________________________________
1 This laboratory offers commercial calibration service and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | 0.5 to 99999 rpm |
| 8 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.