Canada

Intertek Testing Services NA,

Edmonton, Canada

Visit website
A2LA 3738.01ISO/IEC 17025Register refreshed 2026-11-20
One of 3 sites of this organization in our directory. View the organizationPart of the Intertek group: 86 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
3
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 3 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
ISO 80079-36Explosive atmospheres - Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements
ISO 80079-37Explosive atmospheres - Part 37: Non-electrical equipment for explosive atmospheres - Non-electrical type of protection constructional safety ''c'', control of ignition sources ''b'', liquid immersion ''k''

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

3738.01

The scope document we hold says it is valid until 2027-04-30.

View scope

Accredited scope, certificate 3738.01

LineMethodMatrixRange
1CSA C22.2 No. 22; CSA C22.2 No. 25; CSA C22.2 No. 30; CSA C22.2 No. 137; CSA C22.2 No. 145; CSA C22.2 No. 157; CSA C22.2 No. 159; CSA C22.2 No. 174; CSA C22.2 No. 213; IEC/EN/CSA/UL 60079-0; IEC/EN/CSA/UL 60079-1; IEC/EN/CSA/UL 60079-2; IEC/EN/CSA/UL 60079-5; IEC/EN/CSA/UL 60079-6; IEC/EN/CSA/UL 60079-7; IEC/EN/CSA/UL 60079-11; IEC/EN/CSA/UL 60079-13; IEC/EN/CSA/UL 60079-15; IEC/EN/CSA/UL 60079-18; IEC/EN/CSA/UL 60079-25; IEC/EN/CSA/UL 60079-26; IEC/EN/CSA/UL 60079-28; IEC/EN/CSA/UL 60079-29-1; IEC/EN/CSA/UL 60079-30-1; IEC/EN/CSA/UL 60079-31; IEC/EN/CSA/UL 60079-40; IEC/EN/CSA/UL 60079-46; ISO 80079-36; ISO 80079-37; NFPA 496; UL 79; UL 674; UL 844; UL 913; UL 1203; UL 1238; UL 2225; UL 121201; UL 122701; CSA C22.2 No. 0.4; CSA C22.2 No. 14; CSA C22.2 No. 94.1; CSA C22.2 No. 94.2; CSA C22.2 No. 100; CSA C22.2 No. 113; CAN/CSA C22.2 No. 301; IEC/EN/CSA C22.2 No. 60529; IEEE 515.1; NFPA 79; UL 50; UL 50E; UL 429; UL 499; UL 507; UL 508--
2UL 508A; UL 515; UL 698A; UL 1004-1; UL 1004-2; UL 1004-3; UL 1004-6; UL 1004-7; UL 1004-8; UL/ULC 1389; UL 1741; UL/ULC 2200; CAN/ULC 588; CSA/UL/IEC 61010-1; IEC/CSA/UL 61010-2-201; IEC/CSA/UL 61010-2-202; IEC/CAN/CSA/UL C22.2 No. 61010-2-010; IEC/EN/CSA/UL 62990-1; UL 2075; UL 1682; CSA C22.2 No. 182.1; CSA C22.2 No. 182.2; CSA C22.2 No. 182.3--
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited INTERTEK TESTING SERVICES NA, LTD. Edmonton, Alberta, Canada for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 14th day of April 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3738.01 Valid to April 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.