Medizinisches Labor Prof. Dr. Schenk/ Dr. Ansorge & Kollegen GbR Medizinisches Versorgungszentrum
Schwiesaustraße 11, 39124, Magdeburg, Germany
- Accredited standards
- 1
- DAKKS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ISO 23500-3Preparation and quality management of fluids for haemodialysis and related therapies - Part 3: Water for haemodialysis and related therapies
DIN EN ISO 23500-3:2019-11; ISO 23500-3:2019-11; EN ISO 23500-3:2019-11
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
4 lines
ISO/IEC 17025
ActiveD-PL-13291-01-00
Accredited scope, certificate D-PL-13291-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. Anlage zur Akkreditierungsurkunde D-PL-13291-01-00
Gültig ab: 10.07.2025
Ausstellungsdatum: 21.07.2025 Seite 2 von 4
Flexibler Akkreditierungsbereich:
Dem Prüflaboratorium ist, ohne dass es einer vorherigen Information und Zustimmung der DAkkS
bedarf, die freie Auswahl von genormten oder ihnen gleichzusetzenden Prüfverfahren gestattet
(Flexibilisierung nach Kategorie B).
Das Prüflaboratorium verfügt über eine aktuelle Liste aller Prüfverfahren im flexiblen
Akkreditierungsbereich. Die Liste ist öffentlich verfügbar auf der Webpräsenz des
Prüflaboratoriums. | ||
| 3 | DIN EN ISO 23500-3:2019-11; ISO 23500-3:2019-11; EN ISO 23500-3:2019-11 | Water | - |
| 4 | MiQ 23/2018; ADKA-Leitlinie: Aseptische Herstellung und Prüfung applikationsfertiger Parenteralia. Krankenhauspharmazie 2013; 34:39-106 | Sedimentationsplatten; RODAC-Platten (Abklatsch); Nährmedienabfüllungen | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- ÖHMI AnalytikMagdeburg · ~4 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Water
- IHU Geologie und Analytik Gesellschaft für Ingenieur-, Hydro- und Umweltgeologie mbHStendal · ~51 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Water
- USH Umwelt-Service HettstedtLutherstadt Eisleben · ~71 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Water
- I F B Institut für Bioanalytik, Umwelt-Toxikologie und Biotechnologie HalleHalle · ~73 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Water
- IfUA Umweltberatung und Gutachten Gesellschaft mit beschränkter HaftungBitterfeld-Wolfen · ~75 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Water
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.