Midwest Analytical Services
2905 Hilton Road, 48220, Ferndale, MI, United States
Visit website- Accredited standards
- 32
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 32 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.
EPA32
EPA 7.3
EPA 120.1
EPA 200.7
EPA 245.1
EPA 350.2
EPA 410.4
EPA 420.4
EPA 608.3
EPA 624.1
EPA 625.1
EPA 1010
EPA 1311
Show all 32
EPA 1664
EPA 3010
EPA 3050
EPA 3510Separatory Funnel Liquid-Liquid Extraction
EPA 3550Ultrasonic Extraction
EPA 3580
EPA 5030Purge-and-Trap for Aqueous Samples
EPA 5035
EPA 6010Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)
EPA 7470
EPA 7471
EPA 8082
EPA 8260Volatile Organic Compounds by Gas Chromatography/Mass Spectrometry
EPA 8270Semivolatile Organic Compounds by Gas Chromatography/Mass Spectrometry (GC/MS)
EPA 9010
EPA 9040
EPA 9045
EPA 9066
EPA 9095
EPA 9212
EPA 625.1; EPA 8270C; EPA 608.3; EPA 8082A; EPA 9040B; EPA 9045C; EPA 1010; EPA 9095A; EPA 7.3.3.2
SM 4500-NO3D; SM 4500-P E; SM 5210B; SM 1060; EPA 9212; EPA 410.4; SM 4500 CN E; EPA 9010B; SM 4500 CN-G; OIA 1677; SM 2540D; SM 2340B; EPA 1664B; SM 4500-H+B; EPA 9045D; EPA 420.4; EPA 9066; EPA 120.1; SM 2540B; EPA 624.1; EPA 8260B
ISO/IEC 17025:2017; EPA 200.7; EPA 6010B; EPA 245.1; EPA 7470A; EPA 7471A; EPA 350.2
EPA 8260B; EPA 624.1; EPA 625.1; EPA 8270C
EPA 625.1; EPA 8270C
EPA 1311; EPA 3010A; EPA 3050B; EPA 5030; EPA 5035; EPA 3510C; EPA 3550C; EPA 3580
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active381.01
The scope document we hold says it is valid until 2027-02-28.
Accredited scope, certificate 381.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; EPA 200.7; EPA 6010B; EPA 245.1; EPA 7470A; EPA 7471A; EPA 350.2 | Drinking water | - |
| 2 | SM 4500-NO3D; SM 4500-P E; SM 5210B; SM 1060; EPA 9212; EPA 410.4; SM 4500 CN E; EPA 9010B; SM 4500 CN-G; OIA 1677; SM 2540D; SM 2340B; EPA 1664B; SM 4500-H+B; EPA 9045D; EPA 420.4; EPA 9066; EPA 120.1; SM 2540B; EPA 624.1; EPA 8260B | Drinking water | - |
| 3 | EPA 8260B; EPA 624.1; EPA 625.1; EPA 8270C | Drinking water | - |
| 4 | EPA 625.1; EPA 8270C | Drinking water | - |
| 5 | EPA 625.1; EPA 8270C; EPA 608.3; EPA 8082A; EPA 9040B; EPA 9045C; EPA 1010; EPA 9095A; EPA 7.3.3.2 | Drinking water | - |
| 6 | EPA 1311; EPA 3010A; EPA 3050B; EPA 5030; EPA 5035; EPA 3510C; EPA 3550C; EPA 3580 | Drinking water | - |
| 7 | ISO/IEC 17025:2017; A2LA R206 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Microbac Laboratories, Inc. Ohio Valley DivisionMarietta, OH · ~367 kmA2LAShares 4 accredited methods and materialsEPA 200.7EPA 624.1EPA 625.1
- Eurofins Lancaster Laboratories Environment TestingLancaster, PA · ~631 kmA2LAShares 4 accredited methods and materialsEPA 200.7EPA 624.1EPA 625.1
- Eurofins DenverArvada, CO · ~1,856 kmA2LAShares 4 accredited methods and materialsEPA 200.7EPA 624.1EPA 625.1
- Element Materials Technology - Fort WayneFort Wayne, IN · ~226 kmA2LAShares 3 accredited test methodsEPA 200.7EPA 624.1EPA 625.1
- GEL Laboratories, LLCCharleston, SC · ~1,111 kmA2LAShares 3 accredited methods and materialsEPA 624.1EPA 625.1Drinking water
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.