China

Beijing Zhongguancun Shuimu Medical Technology Co.Ltd

No.8 Jiachuang 2nd Road, Tongzhou District, Beijing, People's Republic of China, Beijing, China

Visit website
A2LA 7497.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61326-1-2
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

7497.01

The scope document we hold says it is valid until 2027-07-31.

View scope

Accredited scope, certificate 7497.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; IEC 61000-3-3; IEC 61000-3-2; IEC 61000-4-2--
2IEC 60601-1-2; IEC 61326-1-2; IEC 61326-2-6; ANSI C63Information Technology Equipment (ITE); Multimedia Equipment; Radio Equipment; Household Appliances; Industrial, Scientific and Medical (ISM) Radio-Frequency Equipment; In vitro diagnostic (IVD) medical equipmentto 40000 MHz
3ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.