Accredited standards
2
DAKKS certificate
1
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 2 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ISO 15408
ISO/IEC 18045Information security, cybersecurity and privacy protection - Evaluation criteria for IT security - Requirements and methodology for IT security evaluation

Read from the DAKKS scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.

Scope as published by DAKKS

7 lines
DAKKS

ISO/IEC 17025

Active

D-PL-20522-01-00

The scope document we hold says it is valid until 2029-01-24.

View scope

Accredited scope, certificate D-PL-20522-01-00

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018; VO2019/881; Durchführungsverordnung (EU) 2024/482Produkten aus dem Bereich der Informations- und Kommunikationstechnik (ICT)-
2AIS 20; AIS 25; AIS 26; AIS 31; AIS 34; AIS 37; AIS 46; AIS 49; AIS 50--
3ISO/IEC 15408:2022; ISO/IEC 18045:2022; ISO/IEC TS 23532-1:2021Produkte der Informations- und Kommunikationstechnik (ICT)-
4-S1, S2, S3, S4, S5, S6, S7; N1, N2, N3, N4, N5, N6, N7, N8, N9
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-20522-01-00 Gültig ab: 26.02.2025 Gültig bis: 24.01.2029 Ausstellungsdatum: 26.02.2025 Seite 4 von 7 Zulässige Assurance Family Prüfungen Prüfobjektgruppen (Target of Evaluation) Maximales Assurance Family Level Ausreichend für EAL (informativ) H1, H2, H3, SC, SB ACE_INT S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 - ACE_CCL S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 - ACE_SPD S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 - ACE_OBJ S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 2 - ACE_ECD S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 - ACE_REQ S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 2 - ACE_MCO S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 - ACE_CCO S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 - ADV_ARC S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 7 ADV_FSP S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 6 7 ADV_IMP S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 2 7 ADV_INT S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 3 7 ADV_SPM S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 7 ADV_TDS S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 6 7
-
5-S1; S2; S3; S4; S5; S6; S7; N1; N2; N3; N4; N5; N6; N7; N8; N9
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-20522-01-00 Gültig ab: 26.02.2025 Gültig bis: 24.01.2029 Ausstellungsdatum: 26.02.2025 Seite 5 von 7 Zulässige Assurance Family Prüfungen Prüfobjektgruppen (Target of Evaluation) Maximales Assurance Family Level Ausreichend für EAL (informativ) H1, H2, H3, SC, SB ADV_COMP S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 7 AGD_OPE S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 7 AGD_PRE S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 7 ASE_CCL S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 7 ASE_ECD S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 7 ASE_INT S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 7 ASE_OBJ S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 2 7 ASE_REQ S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 2 7 ASE_SPD S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 7 ASE_TSS S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 2 7 ASE_COMP S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 1 7 ATE_COV S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 3 7 ATE_DPT S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 4 7 ATE_FUN S1, S2, S3, S4, S5, S6, S7 N1, N2, N3, N4, N5, N6, N7, N8, N9 H1, H2, H3, SC, SB 2 7
-
6ISO/IEC TS 23532-1:2021--
7DIN; EN; IEC; ISO--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Emil-Nolde-Straße 7, Bonn, 53113, DE

50.71335, 7.12160

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.