Pratt & Whitney Measurement Systems
66 Douglas Street, 06002-3619, Bloomfield, CT, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2629.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2629.01) 03/02/2026 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
PRATT & WHITNEY MEASUREMENT SYSTEMS, INC.
66 Douglas Street
Bloomfield, CT 06002
Matthew Noonan Phone: 800 371 7174 ext. 400
CALIBRATION
Valid to: February 29, 2028 Certificate Number: 2629.01
In recognition of the successful completion of the A2LA evaluation process, (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations and dimensional inspections
1, 5:
I. Dimensional
Parameter/Equipment
Range CMC2, 4 (±) Comments
Laseruler
(0.5 to 7.5) in
(3.7 + 0.54L) μin
Gage blocks
Labmaster™ Universal
Model 175
(0.5 to 6.5) in
(3.8 + 0.44L) μin
Gage blocks
Labmaster™ Universal
Model 1000A
Up to 40 in
(3.8 + 0.44L) μin
Gage blocks, force
gages
Labmaster™ Universal
Model 1000M
Up to 40 in
(3.8 + 0.44L) μin
Gage blocks, force
gages
Labmaster™ Standard
(0.5 to 7.5) in
(3.7 + 0.54L) μin
Gage blocks
Labmicrometer
(0.5 to 7.5) in
(3.9 + 0.53L) μin
Gage blocks | 0.5 to 7.5 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2629.01) 03/02/2026 Page 2 of 3
Parameter/Equipment
Range CMC2, 4 (±) Comments
Universal
Supermicrometer™
Model 5013 and Model
5043
Up to 2 in
6.1 μin
Gage blocks
Supermicrometer™
Model C3, Model PC3,
and Model SPL3
Up to 1 in
17 μin
Gage blocks
Supermicrometer™
Model B3
Up to 1 in
19 μin
Gage blocks
Digital Measuring
Machine –
Lead Screw
3
Machine Button Bar
Up to 1 in
(1 to 81) in
17 μin
(45 + 1.2L) μin
Gage blocks
Laser system
Standard Measuring
Machine –
Lead Screw
3
Machine Button Bar
Up to 1 in
(1 to 81) in
19 μin
(45 + 1.2L) μin
Gage blocks
Laser system
Plain Cylindrical Ring
Gages
(0.020 to 14) in
(6.2 + 0.57L) μin
Labmaster Universal
Calibration of Ball Bars
(4 to 81) in
(12 + 0.78L) μin
Gage blocks,
Labmaster Universal
Calibration of Long
Gage Blocks
(4 to 20) in
(20 to 40) in
(6.9 + 0.77L) μin
(6.6 + 0.84L) μin
LMU 1000A, LMU
1000M, gage blocks
Electro-Limit Indicator
(0.100 to 0.110) in
3.4 μin
Gage blocks | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2629.01) 03/02/2026 Page 3 of 3
II. Mechanical
Parameter/Equipment
Range CMC2 (±) Comments
Force System –
Fixed Points3,
Labmaster™ Universal,
Laser Measuring Machine,
Digital Measuring Machine,
Standard Measuring Machine,
Supermicrometer™ Model B,
Model C, Model PC, and
Model SPL
-8 ozf
-2 ozf
2 ozf
8 ozf
16 ozf
24 ozf
32 ozf
40 ozf
0.07 ozf
0.05 ozf
0.05 ozf
0.07 ozf
0.12 ozf
0.17 ozf
0.22 ozf
0.27 ozf
Force gage
____________________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of the CMC, L is the numerical value of the nominal length of the device measured in
inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.