L.M.P.
via A. Volta n.15, 00012, Guidonia Montecelio, Italy
Visit website- Accredited standards
- 13
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 13 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC7
IEC 60567
IEC 60666Some materials
Limits written next to it
IEC 60666:2010 - solo/only DBPC
IEC 60814
IEC 61198
IEC 61619
IEC 62535
IEC 62697-1
ASTM3
ASTM D1275
ASTM D1500
ASTM D6304Some methods
Limits written next to it
ASTM D6304-20 - solo/only procedura
Other standards3
DIN 51353
EN 12766-1
EN 12766-3
UNI CEI EN ISO/IEC 17025:2018; CEI EN 60567:2012; IEC 60567:2011; CEI EN 60814:1998; IEC 60814:1997; IEC 62697-1:2012; CEI EN 61619:1998; IEC 61619:1997; DIN 51353:2021; ASTM D1275-24; ASTM D6304-20; CEI EN 61198:1997; IEC 61198:1993; IEC 60666:2010; IEC 62535:2008; EN 12766-1:2000; EN 12766-3:2004; UNI EN 12766-1:2001; UNI EN 12766-3:2005
ASTM D1500-12(2017); UNI CEI EN ISO/IEC 17025:2018
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active01574
Accredited scope, certificate 01574
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; CEI EN 60567:2012; IEC 60567:2011; CEI EN 60814:1998; IEC 60814:1997; IEC 62697-1:2012; CEI EN 61619:1998; IEC 61619:1997; DIN 51353:2021; ASTM D1275-24; ASTM D6304-20; CEI EN 61198:1997; IEC 61198:1993; IEC 60666:2010; IEC 62535:2008; EN 12766-1:2000; EN 12766-3:2004; UNI EN 12766-1:2001; UNI EN 12766-3:2005 | Liquidi isolanti/Insulating liquids; Oli lubrificanti/Lubricating oils; Prodotti petroliferi/Petroleum products; Oli minerali isolanti/Insulating mineral oils; Oli minerali usati/Exhausted mineral oils | See scope document |
| 2 | ASTM D1500-12(2017); UNI CEI EN ISO/IEC 17025:2018 | Prodotti petroliferi/Petroleum products | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.