Precision Installations

501 Gorham Avenue, 07095, Woodbridge, NJ, United States

Visit website
A2LA 1717.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 1717.01 · 4 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1717.01) Revised 02/26/2026 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 PRECISION INSTALLATIONS 501 Gorham Avenue Woodbridge, NJ 07095 Steve Brown Phone: 732 855 1510 CALIBRATION Valid To: March 31, 2026 Certificate Number: 1717.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Dimensional Parameter/Equipment Range CMC 2, 4, 5 (±) Comments Measuring Microscope (Toolmaker’s, Metallurgical, Field of View) 3 – Linear Accuracy Eyepiece Reticle Line Pitch Field of View (FOV) – Measuring Software: Manual Systems Automated Systems Up to 2 in 1x to 2000x Up to 4 in 60 µin (0.0041/|L|) % 32 µin 14 µin Glass line scales and gage blocks Glass line scales Glass scales, gage blocks, precision spheres, pin gages, and ring gages
to 2 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1717.01) Revised 02/26/2026 Page 2 of 3 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Optical and Video Measuring Systems, Optical Comparators, Profile Projectors, Video CMM, Video Measuring Machines, Vision Systems, and Measuring (Toolmaker’s) Microscopes 3 – Linear Accuracy Field of View (FOV) – Measuring Software: Automated Systems Manual Systems: Up to 12 in (12 to 25) in (25 to 50) in Vision Systems: Up to 12 in (12 to 25) in (25 to 50) in Up to 4 in 80 µin (60 + 2L) μin (45 + 3L) μin (45 + 2L) μin (33 + 3L) μin (15 + 4L) μin 14 µin Glass scales and Gage blocks Glass scales, gage blocks, precision spheres, pin gages, and ring gages Video and Vision Systems Squareness 3 – X-Y X-Z and Y-Z Up to (18 x 18) in Up to (3 x 3) in 100 μin 100 μin Glass grids perpendicularity fixture Optical Comparator Magnification (Projector Lens) 3 5x 10x 20x 25x 30x 31.25x 40x 50x 62.5x 100x All other magnifications not listed above between 5x and 500x 0.03 % 0.03 % 0.03 % 0.03 % 0.04 % 0.05 % 0.03 % 0.04 % 0.06 % 0.05 % 0.05 % Glass scales, precision spheres, and pin gages
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1717.01) Revised 02/26/2026 Page 3 of 3 _____________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the length in inches of the calibration standard used during the calibration. 5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited PRECISION INSTALLATIONS Woodbridge, NJ for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 2nd day of April 2024. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1717.01 Valid to March 31, 2026 Revised February 26, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

501 Gorham Avenue, Woodbridge, NJ, 07095, US

40.55418, -74.28600

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.