Registers refreshed 2026-11-20.See refresh dates
United Kingdom

BASEC Group

Presley House, Presley Way, Crownhill, MK8 0ES, Milton Keynes, United Kingdom

Visit website
UKAS 5950ISO/IEC 17025Register refreshed 2026-11-20
Part of the Kiwa group: 40 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
124
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

Our reading of the UKAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 124 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60811 series30
IEC 60811-1
IEC 60811-1-1Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical propertiesSome clauses

Limits written next to it

BS EN 60811-1-1:1995 clause 8

Some clauses. Written next to it on line 10 of UKAS certificate 5950.

BS EN 60811-1-1:1995 clause 8.1

Some clauses. Written next to it on line 10 of UKAS certificate 5950.

BS EN 60811-1-1:1995 clause 8.2

Some clauses. Written next to it on line 10 of UKAS certificate 5950.

BS EN 60811-1-1:1995 clause 8.3

Some clauses. Written next to it on line 10 of UKAS certificate 5950.

BS EN 60811-1-1:1995 clause 9

Some clauses. Written next to it on line 11 of UKAS certificate 5950.

IEC 60811-1-2Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
IEC 60811-1-3Some clauses

Limits written next to it

BS EN 60811-1-3:1995 clause 10

Some clauses. Written next to it on line 11 of UKAS certificate 5950.

BS EN 60811-1-3:1995 clause 11

Some clauses. Written next to it on line 11 of UKAS certificate 5950.

IEC 60811-1-4
IEC 60811-2-1Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
IEC 60811-3
IEC 60811-3-1Some clauses

Limits written next to it

BS EN 60811-3-1:1995 clause 8

Some clauses. Written next to it on line 12 of UKAS certificate 5950.

BS EN 60811-3-1:1995 clause 9

Some clauses. Written next to it on line 12 of UKAS certificate 5950.

IEC 60811-3-2
IEC 60811-4-1
IEC 60811-100
IEC 60811-201
Show all 30
IEC 60811-202
IEC 60811-203
IEC 60811-401Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
IEC 60811-402
IEC 60811-404Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths
IEC 60811-405
IEC 60811-409
IEC 60811-501Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
IEC 60811-502
IEC 60811-503
IEC 60811-504
IEC 60811-505
IEC 60811-506
IEC 60811-507
IEC 60811-508
IEC 60811-509
IEC 60811-605
IEC 60811-606
BS26
BS 903
BS 2782
BS 4553-1
BS 4553-2
BS 4553-3
BS 5308-1
BS 5308-2
BS 5467
BS 6004
BS 6231
BS 6387
BS 6469-99-1Exclusion

Limits written next to it

Electrical and mechanical BS 6469-99-1:1992 Excluding

Exclusion. Written next to it on line 6 of UKAS certificate 5950.

Show all 26
BS 6469-99-2Exclusion

Limits written next to it

BS 6469-99-2:1992 Excluding

Exclusion. Written next to it on line 6 of UKAS certificate 5950.

BS 6500
BS 6622Some clauses

Limits written next to it

BS 6622:2007+C1+C2, Cl.17.8

Some clauses. Written next to it on line 46 of UKAS certificate 5950.

Tan Delta in relation to Voltage BS 6622:2007, C1+C2, Cl.20.4

Some clauses. Written next to it on line 49 of UKAS certificate 5950.

Assembly of 3 core cables BS 6622:2007+C1+C2 Cl.18.11

Some clauses. Written next to it on line 50 of UKAS certificate 5950.

BS 6622:2007+C1+C2, Cl.13

Some clauses. Written next to it on line 50 of UKAS certificate 5950.

BS 6622:2007+C1+C2, Cl.18.4

Some clauses. Written next to it on line 50 of UKAS certificate 5950.

BS 6622:2007+C1+C2, cl.18.10

Some clauses. Written next to it on line 51 of UKAS certificate 5950.

BS 6622:2007+C1+C2, Cl.20.3

Some clauses. Written next to it on line 53 of UKAS certificate 5950.

BS 6622:2007+C1+C2, Cl.19.9

Some clauses. Written next to it on line 60 of UKAS certificate 5950.

BS 6724Exclusion

Limits written next to it

BS 6724:1997 Excluding clauses

Exclusion. Written next to it on line 3 of UKAS certificate 5950.

BS 7211Exclusion

Limits written next to it

BS 7211:2012 Excluding clause

Exclusion. Written next to it on line 4 of UKAS certificate 5950.

BS 7655-1
BS 7655-4
BS 7655-10
BS 7835Some clauses

Limits written next to it

BS 7835: 2007+C1, Cl.18.3,18.4

Some clauses. Written next to it on line 46 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.18.6,19.18

Some clauses. Written next to it on line 46 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.18.8

Some clauses. Written next to it on line 46 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.21.10

Some clauses. Written next to it on line 47 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.21.6

Some clauses. Written next to it on line 47 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.21.7

Some clauses. Written next to it on line 47 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.18.3,18.5

Some clauses. Written next to it on line 48 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.20.3,20.6

Some clauses. Written next to it on line 48 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.20.7

Some clauses. Written next to it on line 48 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.21.4

Some clauses. Written next to it on line 49 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.21.5

Some clauses. Written next to it on line 49 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.14

Some clauses. Written next to it on line 50 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.19.11

Some clauses. Written next to it on line 50 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.19.4

Some clauses. Written next to it on line 50 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.19.9.1,19.13

Some clauses. Written next to it on line 50 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.19.10

Some clauses. Written next to it on line 51 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.19.14

Some clauses. Written next to it on line 51 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.19.7.2

Some clauses. Written next to it on line 51 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.19.8

Some clauses. Written next to it on line 51 of UKAS certificate 5950.

Abrasion Test BS 7835:2007+C1, Cl.20.17

Some clauses. Written next to it on line 52 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.19.9.2

Some clauses. Written next to it on line 54 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.20.14

Some clauses. Written next to it on line 54 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.19.6, 20.4

Some clauses. Written next to it on line 55 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.20.4

Some clauses. Written next to it on line 56 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.20.12

Some clauses. Written next to it on line 58 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.20.8

Some clauses. Written next to it on line 58 of UKAS certificate 5950.

Tear Resistance BS 7835:2007+C1, Cl.20.13

Some clauses. Written next to it on line 58 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.19.16

Some clauses. Written next to it on line 60 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.20.11

Some clauses. Written next to it on line 60 of UKAS certificate 5950.

BS 7835:2007+C1, Cl.20.9

Some clauses. Written next to it on line 60 of UKAS certificate 5950.

Corrosive and acid gas test BS 7835:2007+C1, Cl.20.2

Some clauses. Written next to it on line 60 of UKAS certificate 5950.

BS 7846Exclusion

Limits written next to it

BS 7846:2009 Excluding clauses

Exclusion. Written next to it on line 3 of UKAS certificate 5950.

BS 7846:2015 Excluding clause

Exclusion. Written next to it on line 3 of UKAS certificate 5950.

BS 7870-2Some clauses

Limits written next to it

BS 7870-2, Cl.3.2.1.1, 3.2.5

Some clauses. Written next to it on line 46 of UKAS certificate 5950.

BS 7870-2, Cl.3.10.1

Some clauses. Written next to it on line 48 of UKAS certificate 5950.

BS 7870-2, Cl.3.2.1.1

Some clauses. Written next to it on line 50 of UKAS certificate 5950.

BS 7870-2: 2011, Cl.2.5.10

Some clauses. Written next to it on line 59 of UKAS certificate 5950.

BS 7870-4
BS 7889
BS 8573Exclusion

Limits written next to it

BS 8573:2012 Excluding clause

Exclusion. Written next to it on line 3 of UKAS certificate 5950.

IEC16
IEC 60227-2
IEC 60228
IEC 60229
IEC 60331-1
IEC 60331-2
IEC 60502-1
IEC 60502-2Some clauses

Limits written next to it

DC Voltage test on over-sheath IEC 60502-2: 2014, Cl.16.5

Some clauses. Written next to it on line 46 of UKAS certificate 5950.

IEC 60502-2: 2014, Cl.16.2

Some clauses. Written next to it on line 46 of UKAS certificate 5950.

IEC 60502-2: 2014, Cl.16.4, 17.9

Some clauses. Written next to it on line 46 of UKAS certificate 5950.

IEC 60502-2: 2014, Cl.17.7

Some clauses. Written next to it on line 51 of UKAS certificate 5950.

IEC 60502-2: 2014, Cl.19.11

Some clauses. Written next to it on line 57 of UKAS certificate 5950.

IEC 60502-2: 2014, Cl.19.17

Some clauses. Written next to it on line 57 of UKAS certificate 5950.

IEC 60502-2: 2014, Cl.19.9

Some clauses. Written next to it on line 57 of UKAS certificate 5950.

IEC 60502-2:2014, Cl.19.18, 19.22

Some clauses. Written next to it on line 58 of UKAS certificate 5950.

Thermal Stability Test IEC 60502-2: 2014, Cl.19.19

Some clauses. Written next to it on line 58 of UKAS certificate 5950.

IEC 60702-1
IEC 60754-1
IEC 60754-2
IEC 60840
IEC 60885-3
IEC 61034-1
IEC 61034-2
IEC 61442
IEC 62930
EN15
EN 10002-1
EN 10244-1Some clauses

Limits written next to it

BS EN 10244-1:2009 clause 5.2.1

Some clauses. Written next to it on line 7 of UKAS certificate 5950.

EN 10244-2
EN 45545-2
EN 50200
EN 50214Exclusion

Limits written next to it

BS EN 50214:2006 Excluding

Exclusion. Written next to it on line 4 of UKAS certificate 5950.

BS EN 50214:2006 Excluding table 6

Exclusion. Written next to it on line 4 of UKAS certificate 5950.

EN 50267-2-1
EN 50268-1
EN 50268-2
EN 50305ExclusionSome clauses

Limits written next to it

BS EN 50305:2002 Clause 9 excluding 9

Exclusion. Written next to it on line 14 of UKAS certificate 5950.

Fire BS EN 50305:2002 Clause 9

Some clauses. Written next to it on line 14 of UKAS certificate 5950.

EN 50362
EN 50395Electrical test methods for low voltage energy cables
EN 50396
EN 50575
EN 50618
EN 50363 series15
EN 50363-0
EN 50363-1Exclusion

Limits written next to it

BS EN 50363-1:2005 Excluding

Exclusion. Written next to it on line 7 of UKAS certificate 5950.

EN 50363-2-1Exclusion

Limits written next to it

BS EN 50363-2-1:2005, Excluding

Exclusion. Written next to it on line 7 of UKAS certificate 5950.

EN 50363-2-2
EN 50363-3
EN 50363-4
EN 50363-4-1Exclusion

Limits written next to it

BS EN 50363-4-1:2005 Excluding

Exclusion. Written next to it on line 7 of UKAS certificate 5950.

EN 50363-4-2
EN 50363-5
EN 50363-6
EN 50363-7
EN 50363-8
EN 50363-10
EN 50363-10-1
EN 50363-10-2
EN 50525 series11
EN 50525-1
EN 50525-2-11
EN 50525-2-21
EN 50525-2-31
EN 50525-2-51
EN 50525-2-72
EN 50525-2-82
EN 50525-3-11
EN 50525-3-21
EN 50525-3-31
EN 50525-3-41
IEC 60332 series6
IEC 60332-1-1
IEC 60332-1-2Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
IEC 60332-1-3
IEC 60332-3-21
IEC 60332-3-22
IEC 60332-3-23
EN 50266 series3
EN 50266-2-1
EN 50266-2-2
EN 50266-2-3
Other standards2
ISO 4589-3Plastics - Determination of burning behaviour by oxygen index - Part 3: Elevated-temperature testExclusion

Limits written next to it

excluding BS EN ISO 4589-3

Exclusion. Written next to it on line 14 of UKAS certificate 5950.

ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperatureSome materials

Limits written next to it

BS EN ISO 6892-1:2009 Tensile strength Al wire only A BS EN ISO 6892-1:2016

Some materials. Written next to it on line 7 of UKAS certificate 5950.

Read from the scope as published by UKAS. Register refreshed 2026-11-20.

Scope as published by UKAS

62 lines
UKAS

ISO/IEC 17025

Active

5950

View scope

Location

Presley House, Presley Way, Crownhill, Milton Keynes, MK8 0ES, GB

52.04065, -0.75941

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.