Registers refreshed 2026-11-20.See refresh dates
United States

Cross Country Contractors

1045 N. Carrollton Ave., 70806, Baton Rouge, LA, United States

A2LA 6303.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 6303.01 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; R205--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6303.01) Revised 2/20/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 CROSS COUNTRY CONTRACTORS, INC. 1045 N. Carrollton Ave. Baton Rouge, Louisiana 70806 Joe Amorello Phone: 1 800 742 2040 CALIBRATION Valid To: March 31, 2026 Certificate Number: 6303.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Mechanical Parameter/Equipment Range CMC2, 3, 4 (±) Comments Torque – Measuring Equipment Wrenches Pneumatic Hydraulic (10 to 100) lbf⋅in (50 to 500) lbf⋅in (25 to 250) lbf⋅ft (100 to 1000) lbf⋅ft (750 to 6000) lbf⋅ft (3000 to 30 000) lbf⋅ft 0.79 lbf⋅in (0.79 %) 2.9 lbf⋅in (0.58 %) 1.6 lbf⋅ft (0.6 %) 7.0 lbf⋅ft (0.7 %) 32 lbf⋅ft (0.53 %) 150 lbf⋅ft (0.50 %) Torque transducer AWS transducer (pressure to torque correlation) AWS transducer (pressure to torque correlation) Pressure – Measuring Equipment (10 000 to 40 000) psig 0.14 % Master pressure gauge _______________________ 1 This laboratory offers commercial calibration service.
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6303.01) Revised 2/20/2026 Page 2 of 2 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy.

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1045 N. Carrollton Ave., Baton Rouge, LA, 70806, US

30.44942, -91.18697

Open in Maps

Accreditation data refreshed from the A2LA register on .