ANECO
19 RUE ROGER SALENGRO, 69740, GENAS, France
Visit website- Accredited standards
- 25
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 25 standard numbers and the 16 official names we hold. When no standard matches, it searches the method text of every scope line.
EN14
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
EN 1948-4
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
NF4
NF X43-317
NF X43-329
NF X43-551
NF X44-052
ISO3
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
ISO 23210Stationary source emissions - Determination of PM10/PM2,5 mass concentration in flue gas - Measurement at low concentrations by use of impactors
XP3
XP X43-132
XP X43-136
XP X43-554
Other standards1
FD X43-140
NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4
XP X 43-136; NF EN 1948-1; NF EN ISO 23210; XP X43-554; NF EN 14181; XP X43-132
NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405
NF X 43-551; NF EN 13284-1; NF X 44-052
Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-20.
Scope as published by COFRAC
5 lines
ISO/IEC 17025
Active1-1863
The scope document we hold says it is valid until 2030-12-31.
Accredited scope, certificate 1-1863
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NF EN ISO/IEC 17025 | AIR QUALITY | - |
| 2 | NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405 | Flue gas | - |
| 3 | NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4 | Flue gas | - |
| 4 | XP X 43-136; NF EN 1948-1; NF EN ISO 23210; XP X43-554; NF EN 14181; XP X43-132 | Flue gas | - |
| 5 | NF X 43-551; NF EN 13284-1; NF X 44-052 | Flue gas | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in France
- CARSO - LABORATOIRE SANTÉ ENVIRONNEMENT HYGIÈNE DE LYON (CARSO - LSEHL)VENISSIEUX · ~8 kmCOFRACShares 2 accredited methods and materialsEN 13284-1Flue gas
- CME ENVIRONNEMENTSAINT-ETIENNE · ~58 kmCOFRACShares 2 accredited methods and materialsEN 13284-1Flue gas
- KALI'AIR SUDAIX-EN-PROVENCE · ~247 kmCOFRACShares 2 accredited methods and materialsEN 13284-1Flue gas
- EUROFINS ANALYSES DE L'AIRSAVERNE · ~379 kmCOFRACShares 2 accredited methods and materialsEN 13284-1Flue gas
- MICROPOLLUANTS TECHNOLOGIESAINT-JULIEN-LES-METZ · ~390 kmCOFRACShares 2 accredited methods and materialsEN 13284-1Flue gas
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.