Registers refreshed 2026-11-08.See refresh dates
United States

HITEC Sensor Developments Inc. dba HITEC Sensors

10 Elizabeth Dr., 01824, Chelmsford, MA, United States

Visit website
A2LA 1668.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 1668.01 · 3 lines

Below is the text of the scope document as published.

Part 1 of 3

(A2LA Cert No. 1668.01) 05/05/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 HITEC SENSOR DEVELOPMENTS INC. dba HITEC SENSORS 10 Elizabeth Dr. Chelmsford, MA 01824 William Low Phone: 978-742-9032 CALIBRATION Valid To: May 31, 2027 Certificate Number: 1668.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Mechanical Parameter/Equipment Range CMC2, 3 (±) Comments Force Transducers (1 to 10 000) lbf (10 000 to 300 000) lbf 0.09 % FS 0.08 % FS Weights, hydraulic press with transducer Hydraulic press with transducer Torque Transducers (1.2 to 500) lbf·in (500 to 15 000) lbf·in (15 000 to 360 000) lbf·in 0.10 % FS 0.09 % FS 0.09 % FS Torque arm with weights Torque arm with weights or transducer Torque arm with transducer ____________________________ 1 This laboratory offers commercial calibration service.

Part 2 of 3

(A2LA Cert No. 1668.01) 05/05/2025 Page 2 of 2 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, “FS" indicates the CMC is a function of the full scale of the unit under test. 4 This lab meets A2LA’s P112 Flexible Scope Policy.

Part 3 of 3

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited HITEC SENSOR DEVELOPMENTS INC. DBA HITEC SENSORS Chelmsford , MA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 5th day of May 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1668.01 Valid to May 31, 2027

Extracted from the scope document; tables may not line up. View scope for the original.

Location

10 Elizabeth Dr., Chelmsford, MA, 01824, US

42.59686, -71.35176

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.