Registers refreshed 2026-11-20.See refresh dates
United States

Quality Metrology Systems & Solutions

425 Mill Stone Dr., 45434, Beavercreek, OH, United States

Visit website
A2LA 6667.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 6667.01 · 3 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6667.01) 06/06/2024 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 QUALITY METROLOGY SYSTEMS & SOLUTIONS, LLC 425 Mill Stone Dr. Beavercreek, OH 45434 John Kolaczkowski Phone: 937 272 1415 CALIBRATION Valid To: July 31, 2026 Certificate Number: 6667.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Dimensional Parameter/Equipment Range CMC2 (±) Comments Optical Comparators3 XY Linearity Magnification – Up to 8 in Up to 6 in Up to 12 in 10X 20X 50X 100X 700 µin 1400 µin 2700 µin 3100 µin 3800 µin 3400 µin Glass scale Magnification master Vision Measuring Systems 3 XY Linearity Z Linearity X: Up to 12 in Y: Up to 6 in (1 to 4) in 370 µin 240 µin 150 µin Grid plate Gauge blocks ______________________________ 1 This laboratory offers commercial calibration service and field calibration service.
to 12 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6667.01) 06/06/2024 Page 2 of 2 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

425 Mill Stone Dr., Beavercreek, OH, 45434, US

39.70923, -84.06327

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.