ElectroMagnetic Investigations
8531 NE Cornell Road, Suite 600, 97124, Hillsboro, OR, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at ElectroMagnetic Investigations?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 2569.01Active
Certificates and scope
1ISO/IEC 17025
Active2569.01
The scope document we hold says it is valid until 2027-06-30.
Accredited scope, certificate 2569.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | FCC CFR 47, Part 15, Subpart B (using ANSI C63.4); FCC CFR 47, Part 18 (using MP-5:1986); CISPR 11; EN 55011; KS C 9811; AS CISPR 11; CNS 13438; CISPR 13; EN 55013; CISPR 14; EN 55014-1; KS C 9814-1; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; KS C 9832; AS/NZS CISPR 32; IEC 61326-1; EN 61326-1; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; ICES-001; ICES-003; ICES-005; VCCI-CISPR 32:2016; VCCI V-3; ANSI C63.4 | - | to 40 GHz |
| 2 | electrical | IEC 61000-3-2; EN 61000-3-2; KS C 9610-3-2; IEC 61000-3-3; EN 61000-3-3; KS C 9610-3-3; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-3; EN 61000-4-3; KS C 9610-4-3; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6; IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11; CISPR 24; EN 55024; CISPR 35; EN 55035; KS C 9835; EN 50130-4; IEC 60730-1; IEC 61326; EN 61326; IEC 61326-1; EN 61326-1; IEC 60601-1-2; EN 60601-1-2; KS C IEC 60601-1-2; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; FCC CFR 47, Part 15 Subparts C, E, F, G, and H; ANSI C63.10; FCC CFR 47, Part 15, Subpart D; ANSI 63.17; RSS-GEN; RSS-210; RSS-213; RSS-247; IEEE/ANSI C95.3 | - | to 40 GHz |
| 3 | electrical | FCC CFR 47, Part 15, Subpart B (using ANSI C63.4); FCC CFR 47, Part 18 (using MP-5:1986); CISPR 11; EN 55011; KS C 9811; AS CISPR 11; CISPR 13; EN 55013; CISPR 14-1; EN 55014-1; KS C 9814-1; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; KS C 9832; AS/NZS CISPR 32; CNS 13438; IEC 61326-1; EN 61326-1; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; ICES-001; ICES-003; ICES-005; VCCI-CISPR 32:2016; VCCI V-3; ANSI C63.4 | materials and products | to 18 GHz |
| 4 | electrical | ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.17:2013 | - | to 40000 MHz |
| 5 | electrical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Element Materials Technology Seattle - Bothell 120thBothell, WA · ~256 kmA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 61000-3-2
- HCT AmericaMilpitas, CA · ~904 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Vista Laboratories, Inc.San Clemente, CA · ~1,421 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Intertek Testing Services NAFridley, MN · ~2,312 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- TUV SUD AmericaNew Brighton, MN · ~2,317 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.