Przedsiębiorstwo Produkcyjno Handlowo Usługowe "BM-EKOS"
ul. Sienkiewicza 8/12, 60-817, Poznań, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Przedsiębiorstwo Produkcyjno Handlowo Usługowe "BM-EKOS"?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 976Active
Certificates and scope
1ISO/IEC 17025
ActiveAB 976
The scope document we hold says it is valid until 2028-11-20.
Accredited scope, certificate AB 976
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | environmental | - | Drinking water | - |
| 2 | environmental | PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2017-04; PN-EN 15058:2017-04 | Flue gas | 0.0001 to 3000 g/m3; m/s; Pa; mg/m3; % |
| 3 | environmental | PN-EN 14789 :2017-04; PN-EN 14790 :2017-04; PN-EN 13649:2005; CN/TS 13649:2014; PN-EN 12619:2013-05; PN-EN 1911:2011; PN-EN 13211+AC:2006; ISO 15713:2006; CEN/TS 17340:2020-09; PN-EN 14385:2005 | Flue gas | 3 to 2000 mg/m3 |
| 4 | chemical | PN-EN 14791:2017-04; PN-ISO 10396:2001; PN-Z-04030-7:1994 | Flue gas | 5 to 2000 mg/m3 |
| 5 | environmental | PN-EN ISO 21877 :2020-03; PN-EN 12599:2013-04; Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706); PN-ISO 9613-2:2002; PN-EN ISO 3746:2011+Ap1:2017-09 | Flue gas | 1 to 25 m/s |
| 6 | environmental | PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04; PN-EN ISO 7243:2018-01; PN-EN ISO 11079:2008+Ap1:2013-10; SOP 201 | Workplace environment | 5 to 10000 lx |
| 7 | chemical | PN-Z-04008-7:2002+Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08 | Ambient air | 0.19 to 17 mg/m3 |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- LabAnalitykaBrzeg Dolny · ~127 kmPCAShares 8 accredited methods and materialsEN 13649:2005EN 14791:2017-04PN-N-01307:1994
- Ekologis Piotr Szymański Spółka KomandytowaWrocław · ~142 kmPCAShares 8 accredited methods and materialsEN 13649:2005PN-N-01307:1994PN-Z-04008-7:2002+Az1:2004
- ZEC DIAGPOMWrocław · ~142 kmPCAShares 8 accredited methods and materialsEN 13649:2005EN 14791:2017-04PN-N-01307:1994
- Centrum Badań Środowiska "SORBCHEM"Ruda Śląska · ~273 kmPCAShares 8 accredited methods and materialsEN 13649:2005PN-N-01307:1994PN-Z-04008-7:2002+Az1:2004
- SBB Laboratorium Badań i EkspertyzKatowice · ~283 kmPCAShares 8 accredited methods and materialsEN 13649:2005EN 14791:2017-04PN-N-01307:1994
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.