Registers refreshed 2026-11-20.See refresh dates
Poland

Przedsiębiorstwo Produkcyjno Handlowo Usługowe "BM-EKOS"

ul. Sienkiewicza 8/12, 60-817, Poznań, Poland

Visit website
PCA AB 976ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
26
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 26 standard numbers and the 21 official names we hold. When no standard matches, it searches the method text of every scope line.

EN12
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
EN 12599
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 13649
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
ISO9
ISO 3746Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane
ISO 7243Ergonomics of the thermal environment - Assessment of heat stress using the WBGT (wet bulb globe temperature) index
ISO 7730Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 9613-2Acoustics - Attenuation of sound during propagation outdoors - Part 2: Engineering method for the prediction of sound pressure levels outdoors
ISO 10396Stationary source emissions - Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems
ISO 11079Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effects
ISO 15713Stationary source emissions - Sampling and determination of gaseous fluoride content
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
Other standards5
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-04008-7:2002+Az1:2004
PN-Z-04030-7:1994
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04508:2022-05

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

7 lines
PCA

ISO/IEC 17025

Active

AB 976

The scope document we hold says it is valid until 2028-11-20.

View on PCA

Accredited scope, certificate AB 976

LineMethodMatrixRange
1-Drinking water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 976 Scope of accreditation No. AB 976 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 976 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 27 z/of 17.07.2025 Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr A B 976 z dnia 01.07.2019 r. Cykl akredytacji od 07.11.2024 r. do 20.11.2028 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 976 of 01.07.2019 Accreditation cycle from 07.11.2024 to 20.11.2028 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No. 27, 17.07.2025 1/8 Nazwa i adres / Name and address PRZEDSIĘBIORSTWO PRODUKCYJNO HANDLOWO USŁUGOWE „BM-EKOS” Sp. z o.o. ul. Sienkiewicza 8/12 60-817 Poznań Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - A/13 - C/36/P - G/33, G/34, - G/35, G/36 - N28/P, N/29/P, N/30/P, N/36/P - N/33/P - P/30, P/36 - P/33 - Badania akustyczne i drgań – środowisko ogólne (czynniki fizyczne) / Acopustic and vibration tests of general environment (physical factors) - Badania chemiczne i pobieranie próbek gazów odlotowych/Chemical tests and sampling of waste gases. - Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – oświetlenie, mikroklimat, hałas), środowisko ogólne (czynniki fizyczne – hałas), gazy (gazy odlotowe), pomieszczenia (warunki środowiskowe - wentylacja) / Tests concerning environmental engineering (environmental and climatic) – working environment (harmfu l and nuisance factors – lighting, noise, microclimate), general environment (physical factors – noise), gases (waste gases), facilities (environmental conditions - ventilation) - Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ście ków, gazów odlotowych / Tests of physical properties and sampling of water, drinking water, sewage, waste gases - Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)/Tests of physical properties and sampling – working environment (harmful factors – air) - Pobieranie próbek ścieków, gazów odlotowych – Sampling of sewage, waste gases - Pobieranie próbek – środowisko pracy (czynniki szkodliwe –powietrze) / Sampling – working environment (harmful factors – air) Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl/ The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ EMISJI W ŚRODOWISKU MARCIN BEKAS AB 976
-
2PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2017-04; PN-EN 15058:2017-04Flue gasSee scope document
3PN-EN 14789 :2017-04; PN-EN 14790 :2017-04; PN-EN 13649:2005; CN/TS 13649:2014; PN-EN 12619:2013-05; PN-EN 1911:2011; PN-EN 13211+AC:2006; ISO 15713:2006; CEN/TS 17340:2020-09; PN-EN 14385:2005Flue gas3 to 2000 mg/m3
4PN-EN 14791:2017-04; PN-ISO 10396:2001; PN-Z-04030-7:1994Flue gas5 to 2000 mg/m3
5PN-EN ISO 21877 :2020-03; PN-EN 12599:2013-04; Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706); PN-ISO 9613-2:2002; PN-EN ISO 3746:2011+Ap1:2017-09Flue gas1 to 25 m/s
6PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04; PN-EN ISO 7243:2018-01; PN-EN ISO 11079:2008+Ap1:2013-10; SOP 201Workplace environment5 to 10000 lx
7PN-Z-04008-7:2002+Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08Air0.19 to 17 mg/m3

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Sienkiewicza 8/12, Poznań, 60-817, PL

52.40066, 16.91973

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.