United States

MSI-Viking Gage

8221 Macon Road, 38018, Cordova, TN, United States

Visit website
A2LA 7887.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
12
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 12 scope lines.

A2LA certificate 7887.01 · 12 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017--
2-steel rules & tape measures; indicators; test indicator; gage blocks; cylindrical pins; levels; crimp tools; cylindrical ring, plug gages, setting rings; length standards; feeler/thickness gages; thread plugs
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7887.01) 06/25/2026 Page 2 of 11 Parameter/Equipment Range CMC2, 4 (±) Comments Steel Rules & Tape Measures3 Up to 72 in (0.016 + 250L) µin Mitutoyo 00 block set, Mitutoyo long blocks Indicators3 (0.05 to 4) in (68 + 18L) µin Easson EX-100 ULM Mitutoyo 00 block set surface plate Test Indicator3 Up to 0.060 in 32 µin Easson EX-100 ULM Mitutoyo 00 block set surface plate Gage Blocks (0.05 to 12) in (3.8 + 2L) µin Federal 130B-16 with Mituroyo 00 block set Cylindrical Pins Up to 2 in (25 + 3.2L) µin Easson EX-100 ULM Levels3 Up to 90° 0.052° Angle blocks, surface plates Crimp Tools3 (0.011 to 0.75) in 320 µin Mitutoyo PH- 3500 PIN Cylindrical Ring, Plug Gages, Setting Rings (0.4 to 9) in (25 + 3.2L) µin Easson EX-100 ULM Length Standards (0.5 to 4) in (25 + 3.2L) µin Easson EX-100 ULM Feeler/Thickness Gages (0.01 to 1) in 30 µin Easson EX-100 ULM Thread Plugs (Simple Pitch Diameter) (0.15 to 4) in (82 + 6.8L) µin 3 wire method w/ Easson EX- 100 ULM Thread Plugs (Major Diameter) (0.15 to 4) in (22 + 5L) µin Easson EX-100 ULM
See scope document
3-Thermocouples
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7887.01) 06/25/2026 Page 3 of 11 II. Electrical DC/Low Frequency Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples3 Type E Type J Type K Type S Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) ° C (350 to 650) ° C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-220 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.67 °C 0.39 °C 0.37 °C 0.38 °C 0.41 °C 0.43 °C 0.35 °C 0.33 °C 0.35 °C 0.4 °C 0.48 °C 0.36 °C 0.35 °C 0.42 °C 0.55 °C 0.67 °C 0.56 °C 0.57 °C 0.66 °C 0.44 °C 0.36 °C 0.34 °C Fluke 5500A
See scope document
4-RTDs
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7887.01) 06/25/2026 Page 4 of 11 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTDs3 RTD Pt 385, 100 Ω RTD Pt 3926, 100 Ω RTD PrNi 385, 120 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 610) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C 0.1 °C 0.1 °C 0.1 °C 0.12 °C 0.13 °C 0.15 °C 0.28 °C 0.1 °C 0.1 °C 0.12 °C 0.13 °C 0.15 °C 0.1 °C 0.1 °C 0.12 °C Fluke 5500A, PT-100 output Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV (3.3 to 33) V (33 to 330) V (330 to 1020) V (330 to 1020) V (33 to 330) V (1 to 33) mV (33 to 330) mV (3.3 to 33) V (1 to 33) mV (33 to 330) mV (3.3 to 33) V (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (1 to 10) kHz (10 to 20) kHz 45 Hz to 10 kHz (10 to 20) kHz 2 mV + 1.4 mV/V 0.14 mV + 2.7 mV/V 5 mV + 1 mV/V 22 mV + 1 mV/V 0.16 V + 0.5 mV/V 0.2 V + 2 mV/V 0.7 V + 2.5 mV/V 5 mV + 0.4 mV/V 40 mV + 1 mV/V 0.2 mV + 1.6 mV/V 0.18 mV + 0.5 mV/V 4.5 mV + 0.8 mV/V 0.2 mV + 2 mV/V 0.18 mV + 1 mV/V 5 mV + 1 mV/V Fluke 5500A
-
5-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7887.01) 06/25/2026 Page 5 of 11 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate3 (cont) (1 to 33) mV (33 to 330) mV (3.3 to 33) V (1 to 33) mV (33 to 330) mV (3.3 to 33) V (1 to 33) mV (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.2 mV + 2.2 mV/V 0.3 mV + 3 mV/V 10 mV + 2.5 mV/V 19 mV + 2.5 mV/V 0.5 mV + 8 mV/V 20 mV + 3 mV/V 4.5 mV + 7.2 mV/V Fluke 5500A AC Voltage – Measure3 (1 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (1 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (1 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (1 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (1 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (1 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.067 mV + 3.2 µV/mV 1.1 V + 0.3 mV/V 0.011 V + 10 mV/V 0.099 V + 12 mV/V 0.067 mV + 4.6 µV/mV 0.37 V + 0.3 mV/V 0.0066 V + 3.9 mV/V 0.046 V + 4 mV/V 0.023 mV + 1.3 µV/mV 0.08 V + 0.3 mV/V 0.0052 V + 1.3 mV/V 0.036 V + 1.3 mV/V 0.023 mV + 3.0 µV/mV 0.14 V + 0.5 mV/V 0.0088 V + 2.7 mV/V 0.063 V + 2 mV/V 0.037 mV + 7.1 µV/mV 0.62 V + 0.8 mV/V 0.022 V + 3.7 mV/V 0.11 V + 6.9 mV/V 0.51 mV + 41 µV/mV 4.1 V + 5 mV/V 0.07 V + 41 mV/V 0.61 V + 45 mV/V Agilent 34401 A
See scope document
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7887.01) 06/25/2026 Page 6 of 11 Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Generate (0.07 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1000) V 0.006 % + 3 µV 0.005 % + 5 µV 0.005 % + 50 µV 0.0055 % + 0.5 mV 0.0055 % + 1.5 mV Fluke 5500A-SC300 DC Voltage – Measure3 100 µV to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V 1000 V to 35 kV 3.3 µV + 1.3 µV/mV 0.3 mV + 0.4 µV/mV 0.35 mV + 25 µV/V 0.6 mV + 46 µV/V 0.06 V + 0.4 mV/V 20 V + 0.74 V/kV Agilent 34401A Parameter/Range Frequency CMC2, 5 (±) Comments Capacitance – Generate (0.33 to 0.5) nF (0.5 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF 330 µF to 1.1 mF (1 to 50) kHz 0.061 nF + 0.008 nF/nF 0.079 nF + 0.008 nF/nF 0.084 nF + 0.008 nF/nF 0.11 nF + 0.008 nF/nF 0.36 nF + 0.007 nF/nF 0.36 nF + 0.007 nF/nF 1.1 nF + 0.007 nF/nF 0.072 µF + 0.02 µF/µF 0.19 µF + 0.078 µF/µF 0.19 µF + 0.01 µF/µF 0.19 µF + 0.01 µF/µF 0.28 µF + 0.011 µF/µF 0.36 µF + 0.006 µF/µF 0.19 µF + 0.02 µF/µF Fluke 5500A-SC300 Oscilloscope Square Wave: 50 Ω Load 1 MΩ Load Leveled Sine Flatness: Relative to 50 kHz Edge Rise Time in 50 Ω Load (5 mV to 55 V) Time Marker, 50 Ω Load -6.6 V to 6.6 V -130 V to 130 V 50 kHz to 100 MHz (100 to 300) MHz 50 ms to 5 s 1 ns to 20 ms 0.25 % + 40 µV 0.05 % + 40 µV 1.5 % + 100 µV 3 % + 100 µV (20 + 1000T) µs/s 2.5 µs/s Fluke 5500A-SC300
7-fluid
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7887.01) 06/25/2026 Page 7 of 11 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current – Generate3 (11 to 50) A (50 to 100) A (75 to 150) A (150 to 300) A 0.75 % of reading 0.8 % of reading 0.8 % of reading 0.8 % of reading High current DC supply with load bank in series with EMPRO shunt 50A/50mV with Agilent 34401A Inductance – Generate (0.07 to 10) H 10 mH 2.3 % + 0.5 µH 10 µH IETLS-400 General Radio 1482-H Resistance – Measure (0.2 to 10.99) Ω (11 to 109.99) Ω (110 to 329.99) Ω 330 Ω to 1.099 kΩ (1.1 to 3.299) kΩ (3.3 to 10.99) kΩ (11 to 32.99) kΩ (33 to 109.99) kΩ (110 to 329.99) kΩ 330 kΩ to 3.299 MΩ (3.3 to 20) MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 0.08 Ω 0.96 Ω 0.19 Ω 0.48 Ω 0.77 Ω 1.6 Ω 3.6 Ω 23 Ω 29 Ω 55 Ω 260 Ω 130 Ω 1.2 kΩ 150 kΩ 130 MΩ Fluke 5500A/ SC300 Precision resistor III. Fluid Parameter/Equipment Range CMC2 (±) Comments Pipettes (100 to 200) µL (200 to 500) µL (500 to 1000) µL (1000 to 5000) µL (5000 to 10 000) µL (10 000 to 50 000) µL (50 000 to 100 000) µL 0.14 µL 0.22 µL 0.52 µL 8 µL 9.8 µL 17 µL 29 µL AD4212B-101
-
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7887.01) 06/25/2026 Page 8 of 11 IV. Mechanical Parameter/Equipment Range CMC2 (±) Comments Pressure Gauge Pneumatic (Oil Free) Pneumatic (Oil)3 Hydraulic3 (0.1 to 10) psi (10 to 5000) psi (50 to 5000) psi (5000 to 20 000) psi 0.02 psi 0.05 psi 13 psi 120 psi DMA MPS28 DH Inst. PPCK-P6 Ashcroft 1305D Wika 332.30 Vacuum Gauge – Pneumatic (0.87 to -14.5) psi (35 to 1355) mbar 0.05 psi 0.28 mbar Dama MPS28 Druck ADTS403 Torque Wrenches/Drivers (5 to 50) lbf·in (100 to 1000) lbf·in (60 to 600) lbf·ft 1 % of reading 0.75 % of reading 0.75 % of reading AMS TT-QC-50i CDI 10002-1-ETT CDI 6004-F-ETT Torque Testers (30 to 400) lbf·in (40 to 1200) lbf·ft 0.32 % of reading 0.35 % of reading CDI 2000-152 butterfly wheel w/ Class F weights Skywater torque arm w/ Class F weights Force Gages3 Compression Tension Up to 500 lbf (1000 to 10 000) lbf (10 000 to 100 000) lbf Up to 500 lbf (1000 to 10 000) lbf 0.2 % of reading 0.29 % of reading 0.29 % of reading 0.2 % of reading 0.29 % of reading Class F weight set Omega LC1001-10K W/ DP41-S Amcells LPDCT/DIN3 Class F weight set Omega LC1001-10K W/ DP41-S
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7887.01) 06/25/2026 Page 9 of 11 Parameter/Equipment Range CMC2, 6 (±) Comments Mass – Measure 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 0.000 11 g 0.000 88 g 0.000 92 g 0.000 98 g 0.0011 g 0.0014 g 0.0022 g 0.0041 g 0.053 g 0.05 g 0.055 g Troemner Class 1 Bench Scales, Floor Scales Up to 500 lb 0.2 % of reading Class F weight set Bench Scales (1 to 2000) g Resolution = 0.01 g (0.002 to 1) lb Resolution = 0.0001 lb (0.012 + 0.000 001 3W) g (0.0002 + 0.000 093W) lb Troemner Class 1 weights Class F weights Bench Scales, Balances (1 to 500) mg Resolution = 0.04 mg (0.012 + 0.000 083W) g Ohaus Class 6weights V. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Humidity – Measure3 (5 to 95) % RH 4 % RH Control 4085 & humidity chamber IR Temperature3 (20 to 100) °C (100 to 200) °C (200 to 500) °C 1.2 °C 2.2 °C 3.4 °C Reed BX-500 black body
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7887.01) 06/25/2026 Page 10 of 11 VI. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment3 0.9 Hz to 10 kHz 10 kHz to 2 MHz (2 to 200) MHz 200 MHz to 18 GHz 0.3 Hz 5.7 Hz 41 Hz 0.25 kHz Fluke 5500A- SC300 HP 8660C w/ HP 86603A HP5335A Time – Measure3 10 ns to 100 s 0.2 ns HP5335A Stopwatches & Timers3 (1 to 24) hrs 0.08 s/day HP5335A ________________________________________________________________ 1 This laboratory offers commercial calibration and on-site calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolut ion) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches or millimeters. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7887.01) 06/25/2026 Page 11 of 11 7 This scope meets A2LA’s P112 Flexible Scope Policy.
12ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.