Registers refreshed 2026-11-08.See refresh dates
Germany

Weidmüller Interface GmbH & Co. KG Detmold

Klingenbergstraße 26, 32758, Detmold, Germany

DAKKS D-PL-12095-01-00DAKKS D-PL-12095-01-01DAKKS D-PL-12095-01-02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
65
DAKKS certificates
3
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 65 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60512 series25
IEC 60512-1-1
IEC 60512-2-1
IEC 60512-3-1
IEC 60512-4-1
IEC 60512-5-1
IEC 60512-5-2
IEC 60512-6-2
IEC 60512-6-3
IEC 60512-6-4
IEC 60512-6-5
IEC 60512-8-1
IEC 60512-8-2
Show all 25
IEC 60512-8-3
IEC 60512-9-1
IEC 60512-9-2
IEC 60512-9-5
IEC 60512-11-4
IEC 60512-11-6
IEC 60512-11-7
IEC 60512-11-14
IEC 60512-12-1
IEC 60512-12-4
IEC 60512-12-7
IEC 60512-13-2
IEC 60512-13-5
IEC 60068 series12
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-20
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-42
IEC 60068-2-43
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
IEC 60068-2-60
IEC10
IEC 60695-2-11
IEC 60695-11-5
IEC 60999-1
IEC 60999-2
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-201
IEC 61131-2
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements

Certificate says EN 61326-1. Probably the same standard; not checked against the EN document.

IEC 61984
IEC 62208
IEC 61000 series9
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 60947 series4
IEC 60947-7-1
IEC 60947-7-2
IEC 60947-7-3
IEC 60947-7-4
Other standards5
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements

Certificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.

CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements

Certificate says EN 55016-2-3. Probably the same standard; not checked against the EN document.

EN 50178
EN 61000
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests

Read from the scope as published by DAKKS. Register refreshed 2026-11-06.

Scope as published by DAKKS

19 lines
DAKKS

ISO/IEC 17025

Active

D-PL-12095-01-00

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12095-01-01

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12095-01-02

View scope

Location

Klingenbergstraße 26, Detmold, 32758, DE

51.95095, 8.85317

Open in Maps

Accreditation data refreshed from the DAKKS register on .