Ingenieurbüro Ulbricht
Albert-Schweitzer-Straße 22, 09648, Mittweida, Germany
- Accredited standards
- 1
- DAKKS certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
45688:2014
TA Lärm; DIN 45688:2014; DIN EN ISO/IEC 17025:2018
DIN 45688:2014; TA Lärm 1998-08 (Stand 2017); TA Lärm 1968-07; VDI 2058 Blatt 1:1985-09; 16. BImSchV 1990-06; 18. BImSchV 1991-07; AVV Baulärm 1970-08
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
6 lines
ISO/IEC 17025
ActiveD-PL-21112-01-00
Accredited scope, certificate D-PL-21112-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | TA Lärm; DIN 45688:2014; DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | TA Lärm; 16. BImSchV; 18. BImSchV; AVV Baulärm; LAI-Freizeitlärm-RL; VDI 2058 Blatt 1 | - | - |
| 3 | LAI Fachmodul Immissionsschutz | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-21112-01-01
Accredited scope, certificate D-PL-21112-01-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | DIN 45688:2014; TA Lärm 1998-08 (Stand 2017); TA Lärm 1968-07; VDI 2058 Blatt 1:1985-09; 16. BImSchV 1990-06; 18. BImSchV 1991-07; AVV Baulärm 1970-08 | - | - |
| 3 | LAI-Freizeitlärm -RL 2015 | Geräusche von Freizeitanlagen | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- ITA Ingenieurgesellschaft für Technische Akustik Weimar mbHWeimar · ~118 kmDAKKSShares 1 accredited test method45688:2014
- ALB Akustiklabor Berlin Albrecht, Deter, Passow Partnerschaft von Ingenieuren mbBBerlin · ~163 kmDAKKSShares 1 accredited test method45688:2014
- IBN Bauphysik GmbH & Co.KGIngolstadt · ~271 kmDAKKSShares 1 accredited test method45688:2014
- Big-M Büro für ingenieurgeophysikalische MessungenWeitenhagen · ~342 kmDAKKSShares 1 accredited test method45688:2014
- WIND - consult Ingenieurgesellschaft für umweltschonende Energiewandlung mbHAdmannshagen-Bargeshagen · ~354 kmDAKKSShares 1 accredited test method45688:2014
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.