Arconic Technologies
Arconic Technology Center, 100 Technical Drive, 15068, New Kensington, PA, United States
Visit website- Accredited standards
- 13
- A2LA certificates
- 3
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 13 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM13
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E407Standard Practice for Microetching Metals and Alloys
ASTM E716
ASTM E1251
ASTM E3061
ASTM G34
ASTM G44
ASTM G66
ASTM G67
ASTM G69
ASTM G85
ASTM G110
ASTM B117; SOP-37COR-003; ASTM G44; G47; G49; G38; SOP-37COR-002; -004; -005; -007; ASTM G34; SOP-37COR-006; ASTM G110; SOP-37COR-010; ASTM G69; SOP-37COR-009; ASTM G85; SOP-37COR-012; ASTM G67; SOP-37COR-016; ASTM G66; SOP-37COR-017; ASTM E3; ASTM E407; SOP-38MET-011
ASTM E1251; ASTM E716; SOP-03QNT-004; SOP-03QNT-005; SOP-48CERT-005; ASTM E3061; SOP-48ICP-001; SOP-48ICP-002; SOP-48ICP-003; SOP-48ICP-004; SOP-48ICP-005; SOP-48ICP-006
Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-06.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active1019.01
The scope document we hold says it is valid until 2028-07-31.
Accredited scope, certificate 1019.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM E1251; ASTM E716; SOP-03QNT-004; SOP-03QNT-005; SOP-48CERT-005; ASTM E3061; SOP-48ICP-001; SOP-48ICP-002; SOP-48ICP-003; SOP-48ICP-004; SOP-48ICP-005; SOP-48ICP-006 | aluminum; metals and alloys; fabricated products; ores and minerals; coatings; pigments; lubricants | - |
| 2 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active1019.02
The scope document we hold says it is valid until 2028-07-31.
Accredited scope, certificate 1019.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM B117; SOP-37COR-003; ASTM G44; G47; G49; G38; SOP-37COR-002; -004; -005; -007; ASTM G34; SOP-37COR-006; ASTM G110; SOP-37COR-010; ASTM G69; SOP-37COR-009; ASTM G85; SOP-37COR-012; ASTM G67; SOP-37COR-016; ASTM G66; SOP-37COR-017; ASTM E3; ASTM E407; SOP-38MET-011 | aluminum; metals and alloys; fabricated products | - |
| 2 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active1019.03
The scope document we hold says it is valid until 2028-07-31.
Accredited scope, certificate 1019.03
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | See scope document |
| 2 | - | ElementShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1019.03) 07/06/2026 Page 2 of 2
3 This laboratory performs field calibration activities for these parameters.
4 The notation w/o is defined as weight percent.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
Table 1: Typical Maximum Calibrated Concentrations in Weight Percent
Element Concentration 4 (w/o)
Antimony (Sb), Arsenic (As) 0.1 %
Beryllium (Be) 0.3 %
Bismuth (Bi), Lead (Pb) 1.0 %
Boron (B), Cadmium (Cd) 0.05 %
Calcium (Ca) 0.05 %
Chromium (Cr) 0.4 %
Cobalt (Co) 0.02 %
Copper (Cu) 20 %
Gallium (Ga), Phosphorous (P) 0.05 %
Iron (Fe) 3.5 %
Lithium (Li) 4.0 %
Magnesium (Mg) 12 %
Manganese (Mn), Silver (Ag) 1.5 %
Nickel (Ni) 3.0 %
Scandium (Sc), Titanium (Ti) 0.5 %
Silicon (Si) 18 %
Sodium (Na) 0.04 %
Strontium (Sr) 0.1 %
Tin (Sn) 6.0 %
Vanadium (V) 0.2 %
Zinc (Zn) 11 %
Zirconium (Zr) 0.02 % | See scope document |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Arconic Technology Center, 100 Technical Drive, New Kensington, PA, 15068, US
40.56979, -79.76477
Open in MapsLabs with overlapping accredited scope in United States
- KTA - TATORPittsburgh, PA · ~25 kmA2LAShares 1 accredited test methodASTM B117
- Assured Testing ServicesRidgway, PA · ~129 kmA2LAShares 1 accredited test methodASTM B117
- Akron Rubber DevelopmentBarberton, OH · ~162 kmA2LAShares 1 accredited test methodASTM B117
- Auto Technology CompanyStrongsville, OH · ~194 kmA2LAShares 1 accredited test methodASTM B117
- Architectural Testing, Inc. (An Intertek Company)- YorkYork, PA · ~263 kmA2LAShares 1 accredited test methodASTM B117
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.