Registers refreshed 2026-11-08.See refresh dates
Poland

RADMOR

ul. Hutnicza 3, 81-212, Gdynia, Poland

PCA AB 1132ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
27
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 27 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series11
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase

Certificate says EN 61000-3-12. Probably the same standard; not checked against the EN document.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 60068 series9
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
CISPR 16 series3
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements

Certificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.

CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements

Certificate says EN 55016-2-3. Probably the same standard; not checked against the EN document.

CISPR 16-2-4

Certificate says EN 55016-2-4. Probably the same standard; not checked against the EN document.

Other standards4
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

ETSI EN 300 086
IEC 60529Degrees of protection provided by enclosures (IP Code)

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.

Scope as published by PCA

6 lines
PCA

ISO/IEC 17025

Active

AB 1132

The scope document we hold says it is valid until 2030-01-10.

View on PCA

Accredited scope, certificate AB 1132

LineMethodMatrixRange
1-electrical, telecommunication and electronic products and equipment, military equipment
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1132 Scope of accreditation No. AB 1132 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1132 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 18 z/of 12.12.2025 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ MECHANICZNYCH I FIZYCZNYCH MARIA SZAFRAN Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1132 z dnia 05.11.2020 r. Cykl akredytacji od 12.12.2025 r. do 10.01.2030 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 1132 of 05.11.2020 Accreditation cycle from 12.12.2025 to 10.01.2030 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No 18, 12.12.2025 r. 1/7 Nazwa i adres / Name and address RADMOR S.A. LABORATORIUM BADAWCZE ul. Hutnicza 3 81-212 Gdynia Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - E/6; E/53; E/54; E/15 - F/6; F/53; F/54; F/15 - J/6; J/53; J/54; J/15 - N/6; N/53; N/54; N/15 - Badania elektryczne i elektroniczne w yrobów i wyposażenia elektrycznego, telekomunikacyjnego i elektronicznego, wyposażenia wojskowego/ Electric and electronic tests of electrical, telecommunication and electronic products and equipment , military equipment - Badania kompatybilności elektromagnetycznej wyrobów i wyposażenia elektrycznego, telekomunikacyjnego i elektronicznego, wyposażenia wojskowego/ Electromagnetic compatibility (EMC) tests of electrical, telecommunication and electronic products and equipment, military equipment - Badania mechaniczne wyrobów i wyposażenia elektrycznego, telekomunikacyjnego i elektronicznego, wyposażenia wojskowego/ Mechanical tests of electrical, telecommunication and electro nic products and equipment, military equipment - Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, telekomunikacyjnego i elektronicznego, wyposażenia wojskowego/ Tests of physical properties of electrical, telecommunication and electronic products and equipment, military equipment Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 1132
-
2PN-ETSI EN 300 086 V2.1.2:2017-02; NO-06-A500:2012; MIL-STD 461F; MIL-STD 461G; NO-A-STANAG-4370/AECTP-500-1:2021; PN-EN 55022:2011; PN-EN 55032:2015-09; PN-EN 55016-2-1:2014-09Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczneSee scope document
3NO-06-A500:2012; MIL-STD 461F; MIL-STD 461G; NO-A-STANAG-4370/AECTP-500-1:2021; NO-A-STANAG-4370/AECTP-500-2:2021; PN-EN 55022:2011; PN-EN 55032:2015-09; PN-EN 55016-2-3:2017-06; PN-EN 55016-2-3:2017-06/A2; PN-EN 61000-4-6:2014-04; PN-EN 61000-4-6:2024-03; PN-EN 55016-2-4:2005Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.10 to 18 kHz to GHz
4NO-06-A500:2012 p. 3.17; MIL-STD 461F; MIL-STD 461G; NO-A-STANAG-4370/AECTP-500-1:2021 pkt 3.33; NO-A-STANAG-4370/AECTP-500-2:2021 pkt 3.14; PN-EN 61000-4-3:2021-06; PN-EN 55016-2-4:2005; PN-EN 61000-4-2:2011; MIL-STD 461G; NO-A-STANAG-4370/AECTP-500-1:2021 pkt 3.27; NO-A-STANAG-4370/AECTP-500-2:2021 pkt 3.10; PN-EN 61000-4-5:2014-10; PN-EN 61000-4-4:2013-05; PN-EN 61000-4-11:2020-11; NO-06-A108:2005, p. 3.2; NO-06-A108:2021, p. 3.2; NO-06-A108:2005, p. 3.3; NO-06-A108:2021, p. 3.3; PN-EN 61000-4-8:2010; PN-EN IEC 61000-3-2:2019-04; PN-EN IEC 61000-3-12:2012; PN-EN 61000-3-12:2012/A1:2024-11; PN-EN 61000-3-3:2013-10; PN-EN 61000-3-11:2020Wyposażenie wojskowe; Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczneSee scope document
5PN-EN 60068-2-1: 2009; NO-06-A107:2005; NO-06-A107:2021; MIL-STD 810F; PN-EN 60068-2-2:2009; PN-EN 60068-2-30:2008; PN-EN 60068-2-78:2013-11; PN-EN IEC 60068-2-14:2024-04; PN-EN 60068-2-14:2009; PN-EN 60068-2-6:2008Wyposażenie wojskowe; Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne; Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne.-60 to 170 °C
6PN-EN 60068-2-27:2009; NO-06-A107:2005; NO-06-A107:2021; PN-EN 60068-2-64:2008; MIL-STD- 810F; PN-EN 60068-2-31:2010; MIL-STD 810F; PN-EN 60529:2003; NO-06-A107:2005; NO-06-A107:2021; PN-EN 60529:2003/A2:2014-07Wyposażenie wojskowe; Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne; Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne; Obudowy urządzeń elektrycznych i elektronicznychSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Hutnicza 3, Gdynia, 81-212, PL

54.51650, 18.54027

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.