Registers refreshed 2026-11-08.See refresh dates
United States

Calright Instruments

8715 Mesa Point Terrace, 92154, San Diego, CA, United States

Visit website
A2LA 3441.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
13
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 13 scope lines.

A2LA certificate 3441.01 · 13 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994-to 40 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 2 of 12 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 10 (±) Comments DC Voltage – Measure (0 to 120) mV (0 to 1.2) V (0 to 12) V (0 to 120) V (0 to 1050) V 530 nV + 6.3 nV/mV 0.53 μV + 5.2 μV/V 1.4 μV + 5.2 μV/V 53 μV + 7.4 μV/V 200 μV + 9.1 μV/V Keysight 3458A (option 002) DC Voltage – Generate (0 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (100 to 1020) V 0.0016 % + 0.000 81 mV 0.000 89 % + 0.000 001 6 V 0.000 98 % + 0.000 016 V 0.0014 % + 0.000 13 V 0.0014 % + 0.0014 V Fluke 5522A DC Current – Measure (0 to 120) nA (0 to 1.2) μA (0 to 12) μA (0 to 120) μA (0 to 1.2) mA (0 to 12) mA (0 to 120) mA (0 to 1.05) A 0.0035 % + 52 pA 0.0024 % + 52 pA 0.0026 % + 87 pA 0.0027 % + 760 pA 0.0025 % + 5.3 nA 0.0026 % + 53 nA 0.0045 % + 530 nA 0.013 % + 12 μA Keysight 3458A DC Current – Generate (0 to 329.999) μA (0 to 3.299 99) mA (0 to 32.9999) mA (0 to 329.999) mA (0 to 1.099 99) A (1.1 to 2.999 99) A (0 to 10.9999) A (11 to 20.5) A 0.012 % + 0.016 μA 0.0077 % + 0.000 042 mA 0.0077 % + 0.000 22 mA 0.008 % + 0.002 mA 0.016 % + 0.000 031 A 0.03 % + 0.000 021 A 0.039 % + 0.000 41 A 0.078 % + 0.000 52 A Fluke 5522A DC Resistance – Measure (0 to 12) Ω (0 to 120) Ω (0 to 1.2) kΩ (0 to 12) kΩ (0 to 120) kΩ (0 to 1.2) MΩ (0 to 12) MΩ (0 to 120) MΩ* (0 to 1.2) GΩ* 0.0019 % + 0.07 mΩ 0.0016 % + 0.66 mΩ 0.0014 % + 0.0007 Ω 0.0014 % + 0.007 Ω 0.0014 % + 0.07 Ω 0.0019 % + 0.0024 kΩ 0.0061 % + 0.12 kΩ 0.06 % + 2.1 kΩ 0.58 % + 0.11 MΩ Keysight 3458A 4-wire measurement *2-wire measurement
0 to 120 MΩ
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 3 of 12 Parameter/Equipment Range CMC2, 10 (±) Comments DC Resistance – Generate (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ (0.33 to 1.099 999) MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 0.0046 % + 0.000 78 Ω 0.0017 % + 0.0014 Ω 0.0022 % + 0.0011 Ω 0.0022 % + 0.0016 Ω 0.0022 % + 0.000 001 6 kΩ 0.0022 % + 0.000 016 kΩ 0.0022 % + 0.000 016 kΩ 0.0022 % + 0.000 16 kΩ 0.0022 % + 0.000 16 kΩ 0.0025 % + 0.0016 kΩ 0.0025 % + 0.000 001 6 MΩ 0.0047 % + 0.000 023 MΩ 0.01 % + 0.000 039 MΩ 0.019 % + 0.0019 MΩ 0.039 % + 0.0023 MΩ 0.23 % + 0.078 MΩ 1.2 % + 0.39 MΩ Fluke 5522A Parameter/Range Frequency CMC2, 10 (±) Comments Capacitance – Generate (220 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz Up to 50 Hz 0.37 % + 8 pF 0.39 % + 0.0079 nF 0.4 % + 0.0078 nF 0.2 % + 0.008 nF 0.2 % + 0.077 nF 0.2 % + 0.076 nF 0.2 % + 0.23 nF 0.2 % + 0.000 77 µF 0.2 % + 0.0023 µF 0.21 % + 0.0074 µF 0.32 % + 0.023 µF 0.37 % + 0.073 µF 0.36 % + 0.23 µF Fluke 5522A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 4 of 12 Parameter/Range Frequency CMC2, 10 (±) Comments Capacitance – Generate (cont) (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF Up to 20 Hz Up to 6 Hz Up to 2 Hz Up to 0.6 Hz Up to 0.2 Hz 0.35 % + 0.0008 mF 0.35 % + 0.0024 mF 0.35 % + 0.0077 mF 0.58 % + 0.023 mF 0.85 % + 0.078 mF Fluke 5522A AC Voltage – Measure (1.2 to 12) mV (12 to 120) mV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.029 % + 0.0042 mV 0.012 % + 0.0027 mV 0.025 % + 0.0026 mV 0.11 % + 0.0022 mV 0.58 % + 0.0016 mV 4.6 % + 0.0025 mV 0.009 % + 0.0046 mV 0.0088 % + 0.0023 mV 0.017 % + 0.0023 mV 0.036 % + 0.0023 mV 0.097 % + 0.0024 mV 0.35 % + 0.012 mV Keysight 3458A (synchronously sub-sampled computed true rms technique.) AC Voltage – Measure (12 to 120) mV (0.12 to 1.2) V (1.2 to 12) V 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz 1.2 % + 0.012 mV 1.7 % + 0.012 mV 0.009 % + 0.000 046 V 0.0086 % + 0.000 023 V 0.054 % + 0.000 022 V 0.036 % + 0.000 023 V 0.094 % + 0.000 024 V 0.35 % + 0.000 12 V 1.2 % + 0.000 12 V 1.7 % + 0.000 12 V 0.009 % + 0.000 46 V 0.0086 % + 0.000 23 V Keysight 3458A (synchronously sub-sampled computed true rms technique.)
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 5 of 12 Parameter/Range Frequency CMC2, 10 (±) Comments AC Voltage – Measure (cont) (1.2 to 12) V (12 to 120) V (70 to 700) V (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.017 % + 0.000 23 V 0.036 % + 0.000 23 V 0.093 % + 0.000 23 V 0.35 % + 0.0012 V 1.2 % + 0.0012 V 1.7 % + 0.0012 V 0.023 % + 0.0046 V 0.023 % + 0.0023 V 0.024 % + 0.0023 V 0.041 % + 0.0023 V 0.14 % + 0.0024 V 0.46 % + 0.012 V 1.7 % + 0.012 V 0.046 % + 0.046 V 0.047 % + 0.023 V 0.07 % + 0.023 V 0.14 % + 0.023 V 0.35 % + 0.023 V Keysight 3458A (synchronously sub-sampled computed true rms technique.) AC Voltage – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.064 % + 0.0049 mV 0.0096 % + 0.0075 mV 0.0076 % + 0.011 mV 0.061 % + 0.013 mV 0.27 % + 0.01 mV 0.14 % + 0.33 mV 0.023 % + 0.0067 mV 0.011 % + 0.0068 mV 0.013 % + 0.0067 mV 0.027 % + 0.0075 mV 0.062 % + 0.026 mV 0.16 % + 0.057 mV 0.028 % + 0.000 027 V 0.012 % + 0.000 046 V 0.015 % + 0.000 047 V 0.023 % + 0.000 04 V 0.055 % + 0.000 098 V 0.19 % + 0.000 47 V Fluke 5522A (sine wave)
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 6 of 12 Parameter/Range Frequency CMC2, 10 (±) Comments AC Voltage – Generate (cont) (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (45 to 1000) Hz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.027 % + 0.000 37 V 0.012 % + 0.000 47 V 0.019 % + 0.000 48 V 0.027 % + 0.000 47 V 0.07 % + 0.0013 V 0.015 % + 0.0018 V 0.016 % + 0.0048 V 0.02 % + 0.0046 V 0.025 % + 0.0041 V 0.16 % + 0.039 V 0.023 % + 0.0083 V 0.019 % + 0.013 V 0.023 % + 0.013 V Fluke 5522A (sine wave) AC Current – Measure (6 to 120) μA (0.06 to 1.2) mA (0.6 to 12) mA (6 to 120) mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz 0.47 % + 0.035 μA 0.18 % + 0.035 μA 0.07 % + 0.035 μA 0.07 % + 0.035 μA 0.47 % + 0.000 23 mA 0.18 % + 0.000 23 mA 0.071 % + 0.000 23 mA 0.035 % + 0.000 23 mA 0.071 % + 0.000 23 mA 0.47 % + 0.000 47 mA 0.65 % + 0.0018 mA 0.47 % + 0.0023 mA 0.18 % + 0.0023 mA 0.071 % + 0.0023 mA 0.035 % + 0.0023 mA 0.071 % + 0.0023 mA 0.47 % + 0.0047 mA 0.65 % + 0.018 mA 0.47 % + 0.023 mA 0.18 % + 0.023 mA Keysight 3458A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 7 of 12 Parameter/Range Frequency CMC2, 10 (±) Comments AC Current – Measure (cont) (6 to 120) mA (0.05 to 1.05) A (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 0.071 % + 0.023 mA 0.035 % + 0.023 mA 0.071 % + 0.023 mA 0.47 % + 0.047 mA 0.65 % + 0.18 mA 0.47 % + 0.000 24 A 0.19 % + 0.000 23 A 0.093 % + 0.000 23 A 0.12 % + 0.000 23 A 0.35 % + 0.000 24 A 1.2 % + 0.000 47 A Keysight 3458A AC Current – Generate (29 to 329.99) μA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.16 % + 0.078 μA 0.12 % + 0.078 μA 0.098 % + 0.078 μA 0.23 % + 0.12 μA 0.62 % + 0.16 μA 1.2 % + 0.31 μA 0.16 % + 0.000 12 mA 0.098 % + 0.000 12 mA 0.078 % + 0.000 12 mA 0.16 % + 0.000 16 mA 0.4 % + 0.0002 mA 0.78 % + 0.000 46 mA 0.14 % + 0.0016 mA 0.071 % + 0.0016 mA 0.034 % + 0.0015 mA 0.064 % + 0.0015 mA 0.16 % + 0.0029 mA 0.32 % + 0.0031 mA 0.14 % + 0.015 mA 0.071 % + 0.015 mA 0.033 % + 0.015 mA 0.079 % + 0.039 mA 0.16 % + 0.077 mA 0.32 % + 0.15 mA Fluke 5522A (sine wave)
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 8 of 12 Parameter/Range Frequency CMC2, 10 (±) Comments AC Current – Generate (cont) (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (10 to 45) Hz (45 to 1000) Hz (1to 5) kHz (5 to 10) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz 0.14 % + 0.000 068 A 0.04 % + 0.000 077 A 0.47 % + 0.000 78 A 1.9 % + 0.0039 A 0.14 % + 0.000 061 A 0.059 % + 0.000 044 A 0.47 % + 0.000 76 A 1.9 % + 0.0039 A 0.051 % + 0.0016 A 0.081 % + 0.0016 A 2.3 % + 0.0016 A 0.095 % + 0.0039 A 0.12 % + 0.0039 A 2.3 % + 0.0039 A Fluke 5522A (sine wave) Parameter/Equipment Range CMC2, 3, 10 (±) Comments AC Power – Generate PF = 1 @ (45 to 65) AC Volts (33 to 329.999) mV: AC Amps: (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.999) mA (90 to 329.99) mA (0.33 to 0.8999) A (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A AC Watts (0.1 to 3) mW (0.3 to 10.9) mW (1.09 to 30) mW (3 to 109) mW (10.9 to 300) mW (30 to 726) mW (0.072 to 1.49) W (0.148 to 6.77) W 0.11 % W/W 0.079 % W/W 0.11 % W/W 0.079 % W/W 0.1 % W/W 0.095 % W/W 0.1 % W/W 0.088 % W/W Fluke 5522A (sine wave)
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 9 of 12 Parameter/Equipment Range CMC2, 3, 10 (±) Comments AC Power – Generate (cont) PF = 1 @ (45 to 65) Hz AC Volts (0.33 to 1020) V: AC Amps (3.3 to 8.999) mA: (9 to 32.999) mA (33 to 89.999) mA (90 to 329.99) mA (0.33 to 0.8999) A (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A AC Watts (0.001 to 9.18) W (0.003 to 33.7) W (0.01 to 91.8) W (0.03 to 337) W (0.1 to 918) W (0.3 to 2244) W (0.72 to 4590) W (1.49 to 20 910) W 0.094 % W/W 0.063 % W/W 0.094 % W/W 0.063 % W/W 0.086 % W/W 0.081 % W/W 0.097 % W/W 0.081 % W/W Fluke 5522A (sine wave) Electrical Calibration of Thermocouple Indicating Devices – Measure & Generate Type B Type C Type E Type J Type K (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C 0.37 °C 0.3 °C 0.29 °C 0.3 °C 0.26 °C 0.25 °C 0.28 °C 0.41 °C 0.67 °C 0.41 °C 0.18 °C 0.16 °C 0.18 °C 0.21 °C 0.24 °C 0.18 °C 0.16 °C 0.18 °C 0.22 °C 0.28 °C 0.19 °C 0.18 °C 0.24 °C 0.34 °C Fluke 5522A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 10 of 12 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicating Devices – Measure & Generate (cont) Type L Type N Type R Type S Type T Type U (-200 to -100) °C (-100 to 800) °C (800 to 900) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 600) °C 0.31 °C 0.24 °C 0.18 °C 0.34 °C 0.21 °C 0.19 °C 0.19 °C 0.25 °C 0.46 °C 0.3 °C 0.3 °C 0.35 °C 0.39 °C 0.31 °C 0.33 °C 0.39 °C 0.51 °C 0.22 °C 0.18 °C 0.17 °C 0.45 °C 0.24 °C Fluke 5522A III. Electrical – RF/Microwave Parameter/Equipment Frequency CMC2, 4, 5, 10 (±) Comments Absolute Power – Measure (-30 to 10) dBm (10 to 20) dBm 100 kHz to 4.2 GHz 0.082 dB 0.17 dB Agilent E4418B with Agilent HP 8482A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 11 of 12 Parameter/Equipment Frequency CMC2, 4, 5, 10 (±) Comments Absolute Power – Measure (cont) (-30 to 10) dBm (10 to 20) dBm (-30 to 10) dBm (10 to 20) dBm 50 MHz to 26.5 GHz 50 MHz to 50 GHz 0.098 dB 0.18 dB 0.19 dB 0.24 dB Agilent E4418B with Agilent HP 8485A Agilent E4418B with Agilent HP 8487A IV. Mechanical Parameter Range CMC2, 3 (±) Comments Pressure Gages4 (-15.9 to 0) psig (0 to 200) psig (200 to 550) psig (550 to 2200) psig (2200 to 11 000) psig 0.045 psig 0.12 psig 0.0058 % + 0.0014 psig 0.012 % + 0.027 psig 0.11 % + 0.18 psig Reference pressure gage w/ pressure generator V. Time & Frequency Parameter/Equipment Frequency CMC2, 6, 8 (±) Comments Frequency – Measure Frequency Accuracy Aging Rate Up to 3 GHz 10 MHz 13 pHz/Hz 1.5 pHz/Hz @ 24 h Keysight 53132A counter, Keysight 58503A Frequency – Generate Aging Rate 10 MHz 1.5 pHz/Hz @ 24 h Keysight 58503A _________________________________________________ 1This laboratory offers commercial calibration service.
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3441.01) 06/03/2025 Page 12 of 12 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are percent of reading, unless otherwise indicated. 4 Repeatability of the Unit Under Test has not been utilized in the calculation of the CMC value for this measurement parameter. 5 CMC does not include mismatch between the power sensor and device under test. 6 After 24 hours of GPS lock and uninterrupted tracking of 4 or more satellites 7 This scope meets A2LA’s P112 Flexible Scope Policy. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 In the statement of CMC, L is the length in inch/meters; D is the diameter in inch/meters; H is the height in inch/meters. 10 The measurands stated are generated Fluke 5 522A series of instruments. This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. (Certain parameters are available as fixed source input values only (e. g. Resistance).
13ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

8715 Mesa Point Terrace, San Diego, CA, 92154, US

32.71742, -117.16277

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.