bpa Labor Dr. Pachali
Weißenhofstraße 90, 74235, Erlenbach, Germany
Visit website- Accredited standards
- 30
- DAKKS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 30 standard numbers and the 21 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO16
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 8467Water quality - Determination of permanganate index
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 10301Water quality - Determination of highly volatile halogenated hydrocarbons - Gas-chromatographic methods
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10304-4Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
ISO 10523Water quality - Determination of pH
ISO 10695Water quality - Determination of selected organic nitrogen and phosphorus compounds - Gas chromatographic methods
ISO 14911Water quality - Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography - Method for water and waste water
ISO 15061Water quality - Determination of dissolved bromate - Method by liquid chromatography of ions
ISO 15680Water quality - Gas-chromatographic determination of a number of monocyclic aromatic hydrocarbons, naphthalene and several chlorinated compounds using purge-and-trap and thermal desorption
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
ISO 18857-2Water quality - Determination of selected alkylphenols - Part 2: Gas chromatographic-mass spectrometric determination of alkylphenols, their ethoxylates and bisphenol A in non-filtered samples following solid-phase extraction and derivatisation
ISO 19458Water quality - Sampling for microbiological analysis
DIN8
DIN 38404-10
DIN 38405-13
DIN 38405-17
DIN 38405-32-2
DIN 38405-D21
DIN 38406-5-1
DIN 38407-39
DIN 38409-7
EN5
EN 1483Water quality - Determination of mercury - Method using atomic absorption spectrometry
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 1622Water quality - Determination of the threshold odour number (TON) and threshold flavour number (TFN)
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
Other standards1
TrinkwV §43 Absatz (3)
DIN 38405 -D 21; DIN ISO 5667 -5; DIN EN ISO 19458; DIN EN ISO 9308 -2; Trinkwasserverordnung (TrinkwV) vom 20. Juni 2023
DIN EN ISO 10304 -1 2009 -07; DIN EN ISO 7027 -1 2016 -11; DIN EN ISO 10523 2012 -04; DIN EN ISO 14911 1999 -12; DIN EN ISO 17294 -2 2017 -01; DIN 38409 -7 2005 -12
DIN EN ISO 17294 -2 2017 -01; DIN EN ISO 10304 -4 1999 -07; DIN EN 26777 1993 -04; DIN 38407-39 2011-09; DIN EN ISO 10301 1997 -08; DIN 38406 -5-1 1983 -10; DIN 38404 -10 2012 -12; DIN EN ISO 10304 -1 2009 -07; DIN EN ISO 9308 -2 2014 -06; DIN EN 27888 1993 -11; DIN EN ISO 7887 2012 -04; DIN EN 1622 (B 3) 2006 -10 (Anhang C); DEV B1/2 Teil a 1971; DIN EN ISO 14911 1999 -12; DIN EN 1484 2019 -04; DIN EN ISO 8467 1995 -05; TrinkwV §43 Absatz (3)
DIN EN ISO 15680; DIN 38405 -17; DIN EN ISO 15061; DIN EN ISO 17294 -2; DIN 38405 -13; DIN EN ISO 10301; DIN EN ISO 10304 -1; DIN EN ISO 10695; DIN EN 1483; DIN 38405 -32 -2; DIN 38407 -39; DIN EN ISO 18857 -2
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
5 lines
ISO/IEC 17025
ActiveD-PL-19294-02-00
Accredited scope, certificate D-PL-19294-02-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | Drinking water | - |
| 2 | DIN 38405 -D 21; DIN ISO 5667 -5; DIN EN ISO 19458; DIN EN ISO 9308 -2; Trinkwasserverordnung (TrinkwV) vom 20. Juni 2023 | Drinking water | - |
| 3 | DIN EN ISO 15680; DIN 38405 -17; DIN EN ISO 15061; DIN EN ISO 17294 -2; DIN 38405 -13; DIN EN ISO 10301; DIN EN ISO 10304 -1; DIN EN ISO 10695; DIN EN 1483; DIN 38405 -32 -2; DIN 38407 -39; DIN EN ISO 18857 -2 | Drinking water | - |
| 4 | DIN EN ISO 17294 -2 2017 -01; DIN EN ISO 10304 -4 1999 -07; DIN EN 26777 1993 -04; DIN 38407-39 2011-09; DIN EN ISO 10301 1997 -08; DIN 38406 -5-1 1983 -10; DIN 38404 -10 2012 -12; DIN EN ISO 10304 -1 2009 -07; DIN EN ISO 9308 -2 2014 -06; DIN EN 27888 1993 -11; DIN EN ISO 7887 2012 -04; DIN EN 1622 (B 3) 2006 -10 (Anhang C); DEV B1/2 Teil a 1971; DIN EN ISO 14911 1999 -12; DIN EN 1484 2019 -04; DIN EN ISO 8467 1995 -05; TrinkwV §43 Absatz (3) | - | - |
| 5 | DIN EN ISO 10304 -1 2009 -07; DIN EN ISO 7027 -1 2016 -11; DIN EN ISO 10523 2012 -04; DIN EN ISO 14911 1999 -12; DIN EN ISO 17294 -2 2017 -01; DIN 38409 -7 2005 -12 | Drinking water | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- Limbach AnalyticsMannheim · ~59 kmDAKKSShares 4 accredited methods and materialsEN ISO 9001ISO 5667-5TrinkwV §43 Absatz (3)
- Hessisches Umweltinstitut Schöcke . Unger . Schmidt GmbH & Co. KGSöhrewald · ~231 kmDAKKSShares 4 accredited methods and materialsEN ISO 9001ISO 5667-5TrinkwV §43 Absatz (3)
- Ingenieurbetrieb Dr. Pütz GmbH & Co. KGBrühl · ~250 kmDAKKSShares 4 accredited methods and materialsEN ISO 15680EN ISO 9001ISO 5667-5
- SEWA Laborbetriebsgesellschaft mbHEssen · ~301 kmDAKKSShares 4 accredited methods and materialsEN ISO 15680EN ISO 9001ISO 5667-5
- Medical Physio GmbH Medical Hygiene-LaborHeilbronn · ~5 kmDAKKSShares 3 accredited methods and materialsEN ISO 9001ISO 5667-5Drinking water
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.