LABORATOIRE D' ANALYSES REBM

91 rue Paulin CS 42086, 33081, BORDEAUX, France

COFRAC 1-7537ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
8
COFRAC certificate
1
Sites in our directory
2
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 8 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 25663Water quality - Determination of Kjeldahl nitrogen - Method after mineralization with selenium
EN 27888Water quality - Determination of electrical conductivity
FD T 90-523-2
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 10523Water quality - Determination of pH
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method

Read from the COFRAC scope document we downloaded on 2026-10-09. Register refreshed 2026-11-06.

Scope as published by COFRAC

4 lines
COFRAC

ISO/IEC 17025

Active

1-7537

The scope document we hold says it is valid until 2031-04-30.

View scope

Accredited scope, certificate 1-7537

LineMethodMatrixRange
1NF EN ISO/IEC 17025eau-
2

Extracted from the scope document; tables may not line up. View scope for the original.

Convention N° 8973 LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 2/4 Pour le Directeur Général et par délégation On behalf of the General Director Le Responsable du Pôle Chimie Environnement, Pole manager - Chemistry Environment, La présente attestation n’est valide qu’accompagnée de l’annexe technique. This certificate is only valid if associated with the technical appendix. L’accréditation peut être suspendue, modifiée ou retirée à tout moment. Pour une utilisation appropriée, la portée de l’accréditation et sa validité doivent être vérifiées sur le site internet du Cofrac (www.cofrac.fr). The accreditation can be suspended, modified or withdrawn at any time. For a proper use, the scope of accreditation and its validity should be checked on the Cofrac website (www.cofrac.fr). Cette attestation annule et remplace l’attestation N° 1-7537 Rév 1. This certificate cancels and replaces the certificate N° 1-7537 Rév 1. Seul le texte en français peut engager la responsabilité du Cofrac. The Cofrac's liability applies only to the french text. Comité Français d’Accréditation - 52, rue Jacques Hillairet 75012 PARIS Tél. : +33 (0)1 44 68 82 20 – Fax : 33 (0)1 44 68 82 21 Siret : 397 879 487 00031 www.cofrac.fr
3

Extracted from the scope document; tables may not line up. View scope for the original.

LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 3/4 Section Laboratoires ANNEXE TECHNIQUE à l’attestation N° 1-7537 rév. 2 L’accréditation concerne les prestations réalisées par : Laboratoire d’ analyses REBM 88 cours Louis Fargue 33300 BORDEAUX FRANCE Dans son unité : - Laboratoire d'analyses REBM Elle porte sur : voir pages suivantes
4NF EN 872; NF EN 27888; NF EN ISO 10523; NF EN ISO 7027-1; NF EN ISO 5815-1; Méthode interne Lab M33; NF EN 25663; ISO 15705; FD T 90-523-2Eaux résiduaires; Eaux douces-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.