SIMCO Electronics - Allentown
2125 SW 28th Street, suite 300, 18103, Allentown, PA, United States
Visit website- Scope lines
- 17
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 17 scope lines.
A2LA certificate 1395.09 · 17 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 5 in |
| 2 | ASME/ANSI B1.2-1983; ASME/ANSI B1.3- 2007 | - | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 3 of 16
Parameter/Equipment
Range CMC2, 6, 7 (±) Comments
DC Voltage – Generate3
(cont)
(1.2 to 12) V
(12 to 120) V
(120 to 1020) V
6.3 µV/V + 10 µV
8.7 µV/V + 100 µV
8.6 µV/V + 1.0 mV
Fluke 5560A/1GHz
(1-yr cal interval)
DC Voltage – Measure3
(0 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
6.9 µV/V + 0.3 µV
4.7 µV/V + 0.3 µV
4.6 µV/V + 0.5 µV
6.9 µV/V + 30 µV
21 µV/V + 100 µV*
HP 3458A OPT002
*Add (Vinput/1000)2
times 12 µV/V for
inputs over 100 V
DC High Voltage –
Measure3, 8
Up to 10 kV
0.013 %
Fluke 80E-10,
Hipotronic HD150,
Agilent 3458A
DC Current – Generate3
(0 to 120) µA
120 µA to 1.2 mA
(1.2 to 12) mA
(12 to 120) mA
120 mA to 1.2 A
(1.2 to 3.1) A
(3.1 to 12) A
(11 to 30.2) A
98 µA/A + 0.006 µA
79 µA/A + 0.015 µA
79 µA/A + 0.08 µA
79 µA/A + 0.8 µA
0.12 mA/A + 10 µA
0.23 mA/A + 150 µA
0.24 mA/A + 0.25 mA
0.78 mA/A + 0.5 mA
Fluke 5560A/1GHz
(1-yr cal interval)
DC Current – Measure3
(0 to 100) nA
100 nA to 1 µA
(1 to 10) µA
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(0 to 1) A
(0 to 3) A
(3 to 10) A
160 µA/A + 0.040 nA
28 µA/A + 0.040 nA
25 µA/A + 0.10 nA
24 µA/A + 0.8 nA
23 µA/A + 0.005 µA
23 µA/A + 0.05 µA
43 µA/A + 0.5 µA
0.13 mA/A + 10 µA
0.58 mA/A + 0.2 mA
1.2 mA/A + 0.6 mA
1.8 mA/A + 0.8 mA
HP 3458A OPT002
Fluke 8845A
DC High Current3 –
Measure
Up to 1 A
(> 1 to 10) A
(> 10 to 100) A
(> 100 to 300) A
0.010 %
0.010 %
0.050 %
0.10 %
Guildline 9211A & HP
3458A, Valhalla
2555A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 4 of 16
Parameter/Equipment
Range CMC2, 7 (±) Comments
DC Induced Current3, 9
(0.33 to 1.2) A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30.2) A
(16.5 to < 55) A
(55 to < 150) A
(150 to < 550) A
(550 to 1025) A
120 µA/A + 10 µA
230 µA/A + 150 µA
240 µA/A + 250 µA
780 µA/A + 500 µA
0.43 % + 0.015 A
0.38 % + 0.015 A
0.37 % + 0.05 A
0.38 % + 0.05 A
Fluke 5560A main
output through copper
wire with maximum
Inductance 400 uH
Fluke 5560A with
Fluke 5500-coil
Capacitance – Generate3
(0.2 to 1.2) nF
(1.2 to 12) nF
(12 to 120) nF
(0.12 to 1.2) µF
(1.2 to 12) µF
(12 to 120) µF
(0.12 to 1.2) mF
(1.2 to 12) mF
(112 to 120) mF
0.20 % + 0.002 nF
0.12 % + 0.005 nF
0.12 % + 0.03 nF
0.12 % + 0.0003 µF
0.12 % + 0.003 nF
0.13 % + 0.025 µF
0.21 % + 0.000 25 mF
0.21 % + 0.003 mF
0.40 % + 0.03 mF
Fluke 5560A/1GHz
(1-yr cal interval)
Inductance – Generate3
(13 to 120) µH
(0.12 to 1.2) mH
(1.2 to 12) mH
(12 to 120) mH
(0.12 to 1.2) H
(1.2 to 12) H
(12 to 120) H
0.19 % + 0.2 µH
0.12 % + 0.001 mH
0.12 % + 0.01 mH
0.12 % + 0.1 mH
0.14 % + 0.001 H
0.20 % + 0.01 H
0.22 % + 0.1 H
Fluke 5560A/1GHz
(1-yr cal interval)
Resistance – Generate3
0 Ω
(0 to 12) Ω
(12 to 120) Ω
(0.12 to 1.2) kΩ
(1.2 to 12) kΩ
(12 to 120) kΩ
(0.12 to 1.2) MΩ
(1.2 to 12) MΩ
(12 to 120) MΩ
(120 to 1200) MΩ
16 µΩ
24 µΩ/Ω + 1 mΩ
21 µΩ/Ω + 1 mΩ
21 µΩ/Ω + 2 mΩ
21 µΩ/Ω + 20 mΩ
21 µΩ/Ω + 200 mΩ
22 µΩ/Ω + 2 Ω
29 µΩ/Ω + 30 Ω
360 µΩ/Ω + 2.5 kΩ
3400 µΩ/Ω + 100 kΩ
4-terminal short
Fluke 5560A/1GHz
(1-yr cal interval) | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 5 of 16
Parameter/Equipment
Range CMC2, 6, 7 (±) Comments
Resistance – Generate3
Fixed Values
(Low Resistance)
333 µΩ
1 mΩ
10 mΩ
100 mΩ
1000 mΩ
10 Ω
100 Ω
1000 Ω
10 kΩ
120 µΩ/Ω
110 µΩ/Ω
65 µΩ/Ω
42 µΩ/Ω
63 µΩ/Ω
44 µΩ/Ω
48 µΩ/Ω
64 µΩ/Ω
48 µΩ/Ω
Guildline 9211A
Resistance – Generate3
Fixed Values (High
Resistance, High Voltage)
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
33 µΩ/Ω
32 µΩ/Ω
32 µΩ/Ω
51 µΩ/Ω
180 µΩ/Ω
340 µΩ/Ω
0.58 %
0.74 %
1.2 %
2.4 %
IET LABS
VRS-100-10-1K-BP
Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
18 µΩ/Ω + 50 µΩ
14 µΩ/Ω + 500 µΩ
12 µΩ/Ω + 500 µΩ
12 µΩ/Ω + 5 mΩ
12 µΩ/Ω + 50 mΩ
17 µΩ/Ω + 2.0 Ω
58 µΩ/Ω + 100 Ω
580 µΩ/Ω + 1.0 kΩ
5.8 mΩ/Ω + 10 kΩ
HP 3458A OPT002
Electrical Simulation of
Thermocouples –
Generate/Measure3, 8
Type B
Type E
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(-250 to -150) °C
(-150 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
0.34 ⁰ C
0.26 ⁰ C
0.23 ⁰ C
0.26 ⁰ C
0.34 ⁰ C
0.17 ⁰ C
0.16 ⁰ C
0.18 ⁰ C
0.21 ⁰ C
Fluke 5560A/1GHz
(1-yr cal interval)
ITS-90 or ITS-68
selectable | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 6 of 16
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Simulation of
Thermocouples –
Generate/Measure3, 8 (cont)
Type J
Type K
Type N
Type R
Type S
Type T
Type U
(-250 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-250 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(-200 to 0) °C
(0 to 600) °C
0.20 ⁰ C
0.12 ⁰ C
0.11 ⁰ C
0.12 ⁰ C
0.17 ⁰ C
0.24 ⁰ C
0.14 ⁰ C
0.13 ⁰ C
0.19 ⁰ C
0.29 ⁰ C
0.29 ⁰ C
0.17 ⁰ C
0.15 ⁰ C
0.15 ⁰ C
0.20 ⁰ C
0.40 ⁰ C
0.24 ⁰ C
0.22 ⁰ C
0.27 ⁰ C
0.35 ⁰ C
0.26 ⁰ C
0.27 ⁰ C
0.34 ⁰ C
0.47 ⁰ C
0.16 ⁰ C
0.11 ⁰ C
0.10 ⁰ C
0.31 ⁰ C
0.10 ⁰ C
Fluke 5560A/1 GHz
(1-yr cal interval)
ITS-90 or ITS-68
selectable
Electrical RTD Simulation
– Generate & Measure
Pt385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.041 °C
0.042 °C
0.052 °C
0.073 °C
0.083 °C
0.095 °C
0.18 °C
5560A main output
COMP off; 2 wire or
4 wire | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 7 of 16
Parameter/Equipment
Range CMC2 (±) Comments
Electrical RTD Simulation
– Generate & Measure
(cont)
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
PtNi 285, 120 Ω
(Ni 120)
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.031 °C
0.032 °C
0.033 °C
0.043 °C
0.092 °C
0.10 °C
0.11 °C
0.12 °C
0.031 °C
0.041 °C
0.041 °C
0.052 °C
0.062 °C
0.067 °C
0.078 °C
0.097 °C
0.021 °C
0.022 °C
0.033 °C
0.044 °C
0.054 °C
0.055 °C
0.058 °C
0.16 °C
0.041 °C
0.042 °C
0.052 °C
0.063 °C
0.074 °C
0.095 °C
0.19 °C
0.032 °C
0.042 °C
0.052 °C
0.054 °C
0.063 °C
0.074 °C
0.085 °C
0.18 °C
0.061 °C
0.061 °C
0.11 °C
0.24 °C
5560A main output
COMP off; 2 wire or
4 wire | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 8 of 16
Parameter/Equipment
Range CMC2, 6, 7 (±) Comments
Oscilloscope3 –
Squarewave
Amplitude
Squarewave
Frequency
DC Signal Level
Risetime
Edge Frequency
Leveled Sinewave
Amplitude at 50 kHz
Sinewave Frequency
Leveled Sinewave
Flatness
Wave Generator
Amplitude
Time Markers
Pulse Width
Pulse Period
Impedance –
Measurement
1.0 mV to 120 Vp-p
1.0 mV to 6.6 Vp-p
10 Hz to 10 kHz
(0 to ± 120) V
(0 to ± 6.6) V
≤ 175 ps
900 Hz to 10 MHz
5.0 mV to 5.5 V
p-p
50 kHz to 1100 MHz
50 kHz to 10 MHz
(10 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
1.8 mV to 55 V
p-p
1.8 mV to 2.5 Vp-p
500 ps to 5 s
(4 to 500) ns
200 ns to 22 ms
(40 to 60) Ω
(0.5 to 1.5) MΩ
(5.0 to 50) pF
0.097 % + 40 µV
0.19 % + 40 µV
2.5 µHz/Hz
0.042 % + 40 µV
0.19 % + 40 µV
15 ps
2.5 µHz/Hz
1.6 % + 300 µV
2.5 µHz/Hz
1.2 % + 100 µV
2.4 % + 100 µV
2.4 % + 100 µV
3.2 % + 100 µV
1.7 % + 100 µV
2.3 % + 100 µV
2.5 µs/s
2 ns
2.5 µHz/Hz
0.11 %
0.11 %
5.0 % + 0.5 pF**
Fluke 5560A/1GHz
Into 1 MΩ
Into 50 Ω
Into 1 MΩ
Into 50 Ω
Relative to 50 kHz
Into 1 MΩ
Into 50 Ω
**Within 30
minutes of
capacitance zero | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 9 of 16
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage – Generate3
(1.0 to 12) mV
(12 to 120) mV
(0.12 to 1.2) V
(1.2 to 12) V
(12 to 120) V
(120 to 330) V
(330 to 1020) V
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
(10 to 45) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
(10 to 45) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
(10 to 45) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(3 to 5) Hz
(5 to 10) Hz
(10 to 45) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(3 to 5) Hz
(5 to 10) Hz
(10 to 1000) Hz
1000 Hz to 10 kHz
0.19 % + 7 µV
0.071 % + 7 µV
0.018 % + 6 µV
0.032 % + 6 µV
0.12 % + 15 µV
0.62 % + 30 µV
0.63 % + 30 µV
0.19 % + 7 µV
0.070 % + 7 µV
0.012 % + 6 µV
0.028 % + 8 µV
0.064 % + 20 µV
0.16 % + 30 µV
0.17 % + 30 µV
0.19 % + 75 µV
0.068 % + 70 µV
0.012 % + 60 µV
0.011 % + 8 µV
0.023 % + 14 µV
0.055 % + 40 µV
0.15 % + 80 µV
0.16 % + 80 µV
0.19 % + 750 µV
0.068 % + 750 µV
0.012 % + 350 µV
0.012 % + 50 µV
0.024 % + 50 µV
0.055 % + 130 µV
0.16 % + 600 µV
0.16 % + 600 µV
0.19 % + 7.5 mV
0.068 % + 7.5 mV
0.012 % + 3.5 mV
0.012 % + 0.5 mV
0.026 % + 0.5 mV
0.056 % + 1.3 mV
0.16 % + 20 mV
0.19 % + 75 mV
0.068 % + 75 mV
0.012 % + 8 mV
0.012 % + 8 mV
0.029 % + 13 mV
0.12 % + 75 mV
0.19 % + 75 mV
0.069 % + 75 mV
0.012 % + 80 mV
0.019 % + 80 mV
Fluke 5560A/1GHz
(1-yr cal interval)
(sinewave output)
Fluke 5560A/1GHz
(1-yr cal interval)
(sinewave output) | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 10 of 16
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage – Measure3
(1 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 4) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
0.035 % + 3 µV
0.023 % + 1.1 µV
0.035 % + 1.1 µV
0.12 % + 1.1 µV
0.58 % + 1.1 µV
4.6 % + 2.0 µV
8.1 % + 0.007 mV
0.0084 % + 4 µV
0.0084 % + 2 µV
0.016 % + 2 µV
0.035 % + 2 µV
0.092 % + 2 µV
0.35 % + 10 µV
1.2 % + 10 µV
4.6 % + 0.07 mV
4.6 % + 0.08 mV
17 % + 0.1 mV
0.0082 % + 40 µV
0.0082 % + 20 µV
0.016 % + 20 µV
0.035 % + 20 µV
0.092 % + 20 µV
0.35 % + 0.1 mV
1.2 % + 0.1 mV
4.6 % + 0.0007 V
4.6 % + 0.0008 V
17 % + 0.0010 V
0.0083 % + 0.4 mV
0.0082 % + 0.2 mV
0.016 % + 0.2 mV
0.035 % + 0.2 mV
0.092 % + 0.2 mV
0.35 % + 1.0 mV
1.2 % + 1.0 mV
4.6 % + 0.007 V
4.9 % + 0.008 V
17 % + 0.010 V
0.023 % + 4 mV
0.023 % + 2 mV
0.023 % + 2 mV
0.041 % + 2 mV
0.14 % + 2 mV
0.046 % + 40 mV
0.046 % + 20 mV
0.069 % + 20 mV
0.14 % + 20 mV
HP 3458A OPT002
(sinewave inputs)
AC mode = SYNC
AC band = < 2 MHz
AC band 10 MHz | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 11 of 16
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC High Voltage –
Measure3, 8
Up to 7 kV, 60 Hz
0.17 %
Fluke 80E-10,
Hipotronic HD150,
Agilent 3458A
AC Current – Generate3
(10 to 120) µA
(0.12 to 1.2) mA
(1.2 to 12) mA
(12 to 120) mA
(0.12 to 1.2) A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30.2) A
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
0.033 % + 0.01 µA
0.021 % + 0.01 µA
0.021 % + 0.01 µA
0.12 % + 0.04 µA
0.40 % + 1.0 µA
0.021 % + 0.1 µA
0.020 % + 0.1 µA
0.021 % + 0.1 µA
0.13 % + 0.1 µA
0.40 % + 5.0 µA
0.020 % + 1.0 µA
0.020 % + 1.0 µA
0.022 % + 1.0 µA
0.12 % + 1.0 µA
0.39 % + 10 µA
0.020 % + 10 µA
0.013 % + 5.0 µA
0.020 % + 8.0 µA
0.12 % + 10 µA
0.39 % + 100 µA
0.020 % + 100 µA
0.020 % + 50 µA
0.020 % + 80 µA
0.19 % + 300 µA
0.39 % + 300 µA
0.030 % + 500 µA
0.024 % + 300 µA
0.030 % + 300 µA
0.19 % + 500 µA
0.19 % + 1.0 mA
0.031 % + 0.5 mA
0.025 % + 0.8 mA
0.031 % + 1.0 mA
0.080 % + 10 mA
0.057 % + 8.0 mA
0.39 % + 8.0 mA
Fluke 5560A/1GHz
(1-yr cal interval)
(LCOMP off) | to 7 kV |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 12 of 16
Parameter/Range
Frequency CMC2, 6, 7 (±) Comments
AC Current – Measure3
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(0 to 1) A
(0 to 3) A
(3 to 10) A
45 Hz to 5 kHz
100 Hz to 5 kHz
100 Hz to 5 kHz
100 Hz to 5 kHz
100 Hz to 5 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
0.069 % + 30 nA
0.035 % + 0.2 µA
0.035 % + 2 µA
0.035 % + 20 µA
0.12 % + 200 µA
0.13 % + 0.4 mA
0.18 % + 1.8 mA
0.20 % + 6 mA
HP 3458A OPT002
(sinewave inputs)
Fluke 8845A
AC High Current –
Measure3
(> 0.1 to 2.0) A
(> 0.1 to 2.0) A
(> 2 to 20.0) A
(> 2 to 20.0) A
(> 20 to 100) A
≤ 1 kHz
(> 1 to 10) kHz
≤ 1 kHz
(> 1 to 5) kHz
(0.06 to 1) kHz
0.11 %
0.50 %
0.11 %
0.50 %
0.13 %
Valhalla 2575A,
2555A
AC Induced Current3
(0.12 to 1.2) A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30.2) A
(6.0 to < 60) A
(60 to < 155) A
(155 to < 600) A
(600 to 1500) A
(6.0 to < 155) A
(155 to 600) A
45 Hz to 1 kHz *
45 Hz to 1 kHz *
45 Hz to 1 kHz *
45 Hz to 1 kHz *
(45 to 65) Hz
(65 to 440) Hz
9
0.020 % + 50 µA
0.024 % + 300 µA
0.031 % + 0.5 mA
0.057 % + 8.0 mA
0.42 % + 0.025 A
0.41 % + 0.025 A
0.39 % + 0.09 A
0.40 % + 0.09 A
0.95 % + 0.027 A
0.94 + 0.10 A
Fluke 5560A main
output into copper
wire, maximum
inductive load < 2.5
µH
*For other
frequencies refer to
the AC Current
Generate CMCs up to
30.2 A
Fluke 5560A
(1-yr cal interval)
w/Fluke 5500-COIL | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 13 of 16
IV. Mechanical
Parameter/Equipment
Range CMC2, 6, 11 (±) Comments
Torque – Measuring
Equipment
(1 to 10) ozf∙in
(2 to 20) ozf∙in
(8 to 80) ozf∙in
(2.5 to 25) lbf∙in
(10 to 100) lbf∙in
(10 to 100) ozf∙in
(32 to 320) ozf∙in
(10 to 40) lbf∙in
(40 to 100) lbf∙in
(10 to 40) lbf∙ft
(40 to 100) lbf∙ft
(100 to 600) lbf∙ft
(600 to 1000) lbf∙ft
0.60 %
0.59 %
0.60 %
0.53 %
0.53 %
0.12 % + 0.01 ozf∙in
0.13 % + 0.01 ozf∙in
0.12 % + 0.09 lbf∙in
0.12 % + 0.08 lbf∙in
0.13 % + 0.11 lbf∙ft
0.12 % + 0.12 lbf∙ft
0.12 % + 0.84 lbf∙ft
0.13 % + 1.0 lbf∙ft
AWS ITIO-10
Mountz BMX-20z
Mountz BMX-80z
Mountz LTT-2100:25i
Mountz BMX-100i
AKO TSD1250 system
AKO TSD6000-3 w/
TSD011
TSD111
TSD1011
Pressure – Measuring
Equipment
Vacuum
Pneumatic
3
Hydraulic
Pneumatic
(0.0005 to 0.001) Torr
(0.001 to 100) Torr
(100 to 1000) Torr
(0 to 5.0) in∙H2O
(0 to 0.25) in∙H2O
(0 to 200) psi
(0 to 500) psi
(0 to 1000) psi
(0 to 400) psi
(0 to 1000) psi
(0 to 2000) psi
(15 to 3500) psi
(> 3500 to 10 000) psi
(15 to 9000) psi
(> 9000 to 30 000) psi
(0.2 to 19) psi
(2 to 700) psi
12 %
6.2 %
31 %
0.0033 in∙H
2O
0.000 23 in∙H2O
0.11 psi
0.27 psi
0.60 psi
0.24 psi
0.57 psi
1.1 psi
0.40 psi
0.015 %
1.6 psi
0.021 %
0.0022 % + 0.000 02 psi
0.0022 % + 0.0008 psi
MKS PDR900/925
Ashcroft AQS-1
Eaton UPC5000BBAA
Eaton UPC5000BACA
Ruska RPM4-A70
Ruska RMP4-A200
Ruska 2465
Deadweight system
Force Gauges &
Transducers
3, 9
(Tension & Compression)
(1 to 15) lbf
(> 15 to 500) lbf
0.020 % + 0.0006 lbf
0.0050 % + 0.0073 lbf
Class 7 weights | ||
| 14 | ASTM Class 1 | - | See scope document |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 15 of 16
VI. Time & Frequency
Parameter/Equipment
Range CMC2, 5, 7, 11 (±) Comments
Frequency –
Measuring Equipment
Sinewave3,4
10 MHz Reference
0.01 Hz to 2 MHz
50 kHz to 1100 MHz
10 pHz/Hz
2.5 µHz/Hz
2.5 µHz/Hz
Fluke 910
Fluke 5560A:
main output
scope output
Frequency – Measure
DC to 3000 MHz
12 pHz/Hz + 10 µHz
HP 53131A/GPS
Period = 1/Frequency
Timers & Stopwatches3
Digital
Analog
Up to 100 000 s
Up to 24 hours
1.0 µs/s
0.034 sec/day
1.6 µs/s + 0.037 s
0.046 s/day
HP 53131A
Helmut Klein 4500
HP 53131A
Helmut Klein 4500
Tachometers3
(1 to 6 000 000) RPM
3.1 µRPM/RPM + 0.6R
Fluke 5560A
____________________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’ s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the
laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer’s site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as environment at the place of calibration and for other
possible adverse effects such as those caused by transportation of the calibration equipment. The usual
allowance for the actual uncertainty could result in the actual measurement uncertainty ach ievable on a
customer’s site being larger than the CMC.
4 The output represents the timebase externally locked to the 10 MHz reference, the CMC is the same as
the 10 MHz reference.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
In the statement of CMC, R is the numerical value of the resolution of the device. | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.09) Revised 09/11/2025 Page 16 of 16
6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated.
7 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC are expressed as either a specific value that covers the full range or as a fraction
of the reading plus a fixed floor specification.
8 The contributions from the “best existing device” are not included in the CMC claim.
9 Current output range may be limited due to exceeding compliance voltage.
10 This scope meets A2LA’s P112 Flexible Scope Policy.
11 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 17 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Laboratory TestingHatfield, PA · ~39 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Philadelphia, PALansdale, PA · ~43 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Ellab, Inc.Doylestown, PA · ~43 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Maxpro CorporationHorsham, PA · ~54 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Constellation PowerlabsCoatesville, PA · ~75 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.