Valeo North America,
Test and Validation Laboratory, 1231 A Avenue North, 47274, Seymour, IN, United States
Visit website- Accredited standards
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
CMVSS 108
SAE J575
FMVSS-108; SAE J1383; EXT LTG SDS; PF.90165; TSC 3000G; 26010NDS00; 26550NDS00; 26590NDS; ECE Regs.: 3, 4, 6, 7, 8, 19, 20, 23, 38, 48, 91, 98 and 112; SAE J131; J222; J575; J578; J581; J583; J584; J585; J586; J587; J588; J591; J592; J593; J594; J852; J914; J1306; J1319; J1373; J1383; J1424; J1432; J1889; J1957; J2009; J2039; J2040; J2041; J2042; J2087; J2261; J2282; ASTM B117; SAE J575; JIS D5500
GMW 14906; EXT LTG SDS; PF.90165; TSC 3000G; 26010NDS00; 26550NDS00; 26590NDS; FMVSS-108; CMVSS 108; ECE Regs.: 3; ECE Regs.: 4; ECE Regs.: 6; ECE Regs.: 7; ECE Regs.: 8; ECE Regs.: 19; ECE Regs.: 20; ECE Regs.: 23; ECE Regs.: 38; ECE Regs.: 87; ECE Regs.: 91; ECE Regs.: 98; ECE Regs.: 112; SAE J131; SAE J222; SAE J575; SAE J578; SAE J581; SAE J583; SAE J584; SAE J585; SAE J586; SAE J587; SAE J588; SAE J591; SAE J592; SAE J593; SAE J594; SAE J852; SAE J914; SAE J1306; SAE J1319; SAE J1373; SAE J1383; SAE J1424; SAE J1432; SAE J1889; SAE J1957; SAE J2009; SAE J2039; SAE J2040; SAE J2041; SAE J2042; SAE J2087; SAE J2261; SAE J2282; SAE J3069; JIS D5500; SAE J575e; JIS D1601
SAE J575; EXT LTG SDS; PF.90165; 26010NDS00; 26550NDS00; 26590NDS00; FMVSS-108; JIS D0203; GMW 14906; TSC 3000G; 26010NDS00; 26550NDS00; 26590NDS00
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active311.01
The scope document we hold says it is valid until 2027-08-31.
Accredited scope, certificate 311.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | FMVSS-108; SAE J1383; EXT LTG SDS; PF.90165; TSC 3000G; 26010NDS00; 26550NDS00; 26590NDS; ECE Regs.: 3, 4, 6, 7, 8, 19, 20, 23, 38, 48, 91, 98 and 112; SAE J131; J222; J575; J578; J581; J583; J584; J585; J586; J587; J588; J591; J592; J593; J594; J852; J914; J1306; J1319; J1373; J1383; J1424; J1432; J1889; J1957; J2009; J2039; J2040; J2041; J2042; J2087; J2261; J2282; ASTM B117; SAE J575; JIS D5500 | automotive light systems: sealed and non-sealed headlamps, reflex side markers, park/turn, rear lights, backup lamps, clearance lamps, cornering lamps, identification lamps, license plate lamps, stop lamps, motorcycle, driving lamps, fog lamps, and spot lamps | - |
| 2 | GMW 14906; EXT LTG SDS; PF.90165; TSC 3000G; 26010NDS00; 26550NDS00; 26590NDS; FMVSS-108; CMVSS 108; ECE Regs.: 3; ECE Regs.: 4; ECE Regs.: 6; ECE Regs.: 7; ECE Regs.: 8; ECE Regs.: 19; ECE Regs.: 20; ECE Regs.: 23; ECE Regs.: 38; ECE Regs.: 87; ECE Regs.: 91; ECE Regs.: 98; ECE Regs.: 112; SAE J131; SAE J222; SAE J575; SAE J578; SAE J581; SAE J583; SAE J584; SAE J585; SAE J586; SAE J587; SAE J588; SAE J591; SAE J592; SAE J593; SAE J594; SAE J852; SAE J914; SAE J1306; SAE J1319; SAE J1373; SAE J1383; SAE J1424; SAE J1432; SAE J1889; SAE J1957; SAE J2009; SAE J2039; SAE J2040; SAE J2041; SAE J2042; SAE J2087; SAE J2261; SAE J2282; SAE J3069; JIS D5500; SAE J575e; JIS D1601 | - | See scope document |
| 3 | SAE J575; EXT LTG SDS; PF.90165; 26010NDS00; 26550NDS00; 26590NDS00; FMVSS-108; JIS D0203; GMW 14906; TSC 3000G; 26010NDS00; 26550NDS00; 26590NDS00 | - | - |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
VALEO NORTH AMERICA, INC
Seymour, IN
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 15th day of August 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 0311.01
Valid August 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Test and Validation Laboratory, 1231 A Avenue North, Seymour, IN, 47274, US
38.95922, -85.89025
Open in MapsLabs with overlapping accredited scope in United States
- Elite Electronic EngineeringDowners Grove, IL · ~363 kmA2LAShares 2 accredited test methodsASTM B117CMVSS 108
- Sapphire Technical Solutions, L.L.C.Pineville, NC · ~619 kmA2LAShares 2 accredited test methodsCMVSS 108SAE J575
- Calvary IndustriesFairfield, OH · ~127 kmA2LAShares 1 accredited test methodASTM B117
- ACT Test ServicesHillsdale, MI · ~348 kmA2LAShares 1 accredited test methodASTM B117
- Accu Labs Inc.Chicago, IL · ~352 kmA2LAShares 1 accredited test methodASTM B117
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.