Registers refreshed 2026-11-20.See refresh dates

BS 2011 Accredited Testing Labs Worldwide

15 accredited laboratories in 1 country hold BS 2011 in their accredited scope. We don't know yet whether 7 of them take outside work. Primary accreditors include United Kingdom Accreditation Service.

Total labs
15
Countries
1

Available in 1 Country

Sample labs

Environmental Test Services
Berkshire, GB

BS 2011:B:1977(1980) COATINGS: NON-METALLIC -Constant BS EN 60068-2-2:1993 COMPUTERS AND Max temp: +200°C Tests Ba, Bb, Bd (forced air PERIPHERALS Max chamber size: circulation, Methods A and B) ELECTRICAL/ELECTRONIC 0.47

BSI Assurance UK
Hemel Hempstead, GB

BS 2011:Part 2.1:1977(1987) Test Ca BS 2011:Part 2.1:1990 Test Cb IEC 60068-2-3:1969 BS 2011:Part 2.1:1981(1987) Test Db A Electrical, Electronic and Mechanical Components High Humidity/Temperature Temp range: -40 °C t

Element Materials Technology Warwick
Warwick, GB

BS 2011: Fd:1973(1984) BS 2011: Fda:1973(1984) BS 2011: Fdb:1973(1984) BS 2011: Fdc:1973(1984) BS EN 60068-2-6:2008:Fc BS EN 60945:2002 IEC 60068-2-64:2008 IEC 68-2-6:1993 TR 2130C:2002 TR 2130D:2011 TR 2130E:2014 BS 3G100: Part

Alphatech
Suffolk, GB

BS 2011:Fc:1983(1986) PRODUCTS AND COMPONENTS BS EN 60068-2-6:1996 Freq range: 2 to 2000 Hz BS EN 60068-2-6:2008 ELECTRICAL/ELECTRONIC BS EN 60068-2-50:200 CONNECTORS Peak thrust: 40 kN BS EN 60068-2-51:2000 ELECTRO-MECHANICAL

ZF Automotive UK
West Midlands, GB

BS 2011:2.1 Fc:1983 Frequency range: IEC 68-2-6:1982 3 Hz to 2.5 kHz BS EN 60068-2-6 :1996 Max mass: 700 kg IEC 68-2-6 :1995 Max size: 1.0 m x 1.0 m x 0.8 m BS EN 60068-2-6 :2008 IEC 68-2-6:2

Javer Labs Ltd
Nottingham, GB

BS 2011:Part 2.1J:1989 Test J and Guidance (withdrawn) DEF STAN 00-35 Part 3 Issue 4 Chapter 4-01 Mould Growth DEF STAN 00-35 Part 3 Issue 5 Chapter 4-01 Mould Growth BS EN 60068-2-10:2005+A1:2018 END

BRE GLOBAL LIMITED Incorporating LPC Testing, BRE Testing
Watford, GB

BS 2011: Part 2.1Kb:1987 IEC 68-2-52:1996 BS EN 60068-2-52:1996 ISO 9227:1990 (NSS test) A Sulphur dioxide Chamber size: 0.5 m x 0.5 m x 0.7 m BS 2011: Part 2.1Kc:1991 IEC 68-2-42:1982 BS EN 60068-2-42:2003 A Dyn

Product Assessment & Reliability Centre Limited T/A PARC
Devon, GB

BS 2011:Ca:1977 High/Low Temperature & Humidity IEC 68-2-3:1969 - Steady State and Cyclic IEC 68-2-56:1988 BS EN 60068-2-78:Cab:2002,2013 Temp range: -70°C to +180°C BS EN 60068-2-30:1999 Humidity range: 15-98% RH BS EN 60

Penny and Giles Aerospace Ltd, an operating division of Curtiss-Wright Controls
Dorset, GB
We don't know yet whether this lab takes outside work.

BS 2011:M:1984 IEC 68-2-13:1983 Subsection 3.2:1970 DEF STAN 07-55:1975 Test B21 DEF STAN 00-035 Part 3 Issue 6 Test CL11 MIL-STD 202G:2002 Method 105C MIL STD 202H:2015 MIL-STD 810F:2000 Method 500.4 MIL-STD 810G:2008 Method 500.

Leonardo UK
Edinburgh, GB
We don't know yet whether this lab takes outside work.

BS 2011 Ea Half sine, terminal peak saw tooth, IEC 60068-2-27:1987 trapezoidal or complex transient BS EN 60068-2-27:1993 BS EN 60068-2-27:2009 MIL-STD-810B, 516.1 Severity: to 600 g MIL-STD-810C, 516.2, Procedures I to V

Boeing Test Facility
Brisbane, AU
We don't know yet whether this lab takes outside work.

BS 2011: Part 2.1: Test Ka; BS EN 60068-2-52: Test Kb; MIL-STD-810G, Method 509.5; MIL-STD-810G CN1, Method 509.6; MIL-STD-810H, Method 509.7; MIL-STD-810H CN1, Method 509.8 Thermal Shock DEF(AUST)5681, Section 7.2.6, Procedure A;

Chemring Countermeasures
Wiltshire, GB
We don't know yet whether this lab takes outside work.

BS 2011:Fc:1983 superseded BS 2011:Fd:1973(1984)superseded BS3G100:Part 2:Section 3: Sub-Section 3.1:1969(1983) BS EN 60068-2-6:Fc:2008 BS EN 60068-2-64:1995 BS EN 60068-2-7:Ga:1987 BS EN 60068-2-29:Eb:1987 & 1993 DEF STAN 00-35 Par

JCS Technology
North Somerset, GB
We don't know yet whether this lab takes outside work.

BS 2011:Part 2.1J:1989 (IEC68-2- 10:1988) withdrawn ELECTRONIC COMPONENTS Mould Growth TP7012 based on BS EN 60068-2-10:2005+A1:2018 Part 2-10 Test J and guidance11 (IEC 60068-2-10:2005+A1:2018, EN 60068-2-10:2005+A1:2018) PLA

MBDA UK Limited
Hertfordshire, GB
We don't know yet whether this lab takes outside work.

BS 2011:Fc:1983 BS 2011:Fd:1973 BS 3G100:Part 2 Subsect 3.1:1969(1983) DEF-STAN 07-55:1975 Test A1 and A2 DEF-STAN 00-35 Pt3 Is4 Test M1, M2 DEF-STAN 00-035 Pt3 Is5 Test M1, M2 DEF-STAN 00-035 Pt3 Is6 Test M1, M2 DEF-STAN 81-41/

BAE SYSTEMS (Operations)
Kent, GB
We don't know yet whether this lab takes outside work.

BS 2011:Ec:1977 (IEC 68-2- Coatings: Metallic Max mass: 100 kg 31:1993) status withdrawn Computers and Peripherals Max size: 90 cm x 90 cm superseded by Domestic Appliances: Electrical BS EN 60068-2-32:1993 status Domestic Appli