Registers refreshed 2026-11-20.See refresh dates

IEC 60947-4-3 Accredited Testing Labs Worldwide

Part of a series

See all 90 labs worldwide for IEC 60947 (any part)

Part 1: 63 labs · Part 1-401: 1 lab · Part 2: 36 labs · Part 3: 32 labs · Part 4-1: 34 labs · Part 4-2: 25 labs and 22 more parts

Go to the series ↑

24 accredited laboratories in 6 countries hold IEC 60947-4-3 in their accredited scope. We don't know yet whether 8 of them take outside work. Primary accreditors include Deutsche Akkreditierungsstelle, Polish Centre for Accreditation.

Total labs
24
Countries
6

Available in 6 Countries

Germany
17 labs
Poland
3 labs
Canada
1 lab
Japan
1 lab
Netherlands
1 lab
United States
1 lab

Sample labs

TÜV Technische Überwachung Hessen GmbH EMV-Labor
Kassel, DE

IEC 60947-4-3:2014) Nur Abschnitt 8.3 EMV IEC 60947-4-3:2020 Low-voltage switchgear and controlgear – Part 4-3: Contactors and motor-starters – Semiconductor controllers and contactors for non-motor loads Only subclause 8.3 EM

TÜV Rheinland Japan Ltd. Yokohama Laboratories Global Technology Assessment Center
JP

Department Standard / in house procedure / Version Title of standard or in house procedure (deviaBons / modificaBons of standard) LocaBon/ reducBons Low Voltage IEC 60947 -1:2020 EN IEC 60947-1:2021 DIN EN IEC 60947- 1:202

VDE Prüf- und Zertifizierungsinstitut
Offenbach am Main, DE

IEC 60947-4-3:2014 IEC 60947-4-3:2020-07 EN 60947-4-3:2014 VDE 0660-109:2015 Niederspannungsschaltgeräte - Teil 4-3: Schütze und Motorstarter - Halbleiter- Steuergeräte und -Schütze für nichtmotorische Lasten für Wechselspannung C

TUV SUD Canada
Gormley, CA

IEC 60947-4-3 Welding Equipment IEC 60974-10; IEC 62135-2 Machine Tools (Emissions and Immunity) EN 50370-1; EN 50370-2; IEC 61800-3 (Excluding 5.2.1.2, 5.2.2.2, 5.2.3.2); EN 61800-3 (Excluding 5.2.1.2, 5.2.2.2, 5.2.3.2) Autom

CSA Group Bayern
Plattling, DE

IEC 60947-4-3:2014) 8.3 und Anhang D EMV IEC 60947-4-3:2014 Low-voltage switchgear and controlgear – Part 4-3: Contactors and motor-starters – AC semiconductor controllers and contactors for non-motor loads Only subclause 8.3 and

Stowarzyszenie Elektryków Polskich, ul. Świętokrzyska 14, 00-050 Warszawa, Biuro Badawcze ds. Jakości
Warszawa, PL

IEC 60947-4-3:2014 z wyłączeniem p. 9.4 Aparaty i łączniki sterownicze Trwałość znakowania Przyrosty temperatury Właściwości dielektryczne Odstępy izolacyjne powierzchniowe i powietrzne Zdolność załączania i wyłączania elementów łą

Institute for International Product Safety
Bonn, DE

IEC 60947-4-3:2014) Deutsche Fassung EN 60947-4-3:2014 INSpg IEC 60947 -4-3:2014 Low -voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads

EMC Test NRW GmbH electromagnetic compatibility
Dortmund, DE

Bereich Norm oder Hausverfahren / Ausgabestand Titel der Norm oder des Hausverfahrens Einschränkungen zum Prüfverfahren EMV ÖVE/ÖNORM EN 60947-4-3:2015 Niederspannungsschaltgeräte - Teil 4-3: Schütze und Motorstarter - Halbleiter

DEKRA Certification
ARNHEM, NL

IEC 60947-4-3, EN 60947-4-3 IEC 60947-5-1, EN 60947-5-1 IEC 60947-6-1, EN 60947-6-1 IEC 60947-6-2, EN 60947-6-2 IEC 60947-7-1, EN 60947-7-1 IEC 60947-7-2, EN 60947-7-2 IEC 60947-7-3, EN 60947-7-3 IEC 60947-7-4, EN 60947-7-4 IEC 60

steep GmbH EMV-Zentrum
Bonn, DE

IEC 60947-4-3:2014); Deutsche Fassung EN 60947-4-3:2014 Kapitel 8.3 und 9.1 EMV IEC 60947-4-3:2014 Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non

EMCCons Dr. RASEK GmbH & Co. KG
Ebermannstadt, DE

IEC 60947-4-3:2014) EMV IEC 60947 -5-1:2016 + COR1:2016 Low -voltage switchgear and controlgear; Part 5-2: Control circuit devices and switching elements; Electromechanical control circuit devices EMV EN 60947 -5-1: 2017

PHOENIX TESTLAB
Blomberg, DE

IEC 60947-4-3:2014); Deutsche Fassung EN 60947-4-3:2014 nur Kapitel 8.3 EMV IEC: 60947-4-3 ed. 2.0 2014 Low-voltage switchgear and controlgear – Part 4- 3: Contactors and motor-starters –AC semiconductor controllers and contactors for

IPH Institut "Prüffeld für elektrische Hochleistungstechnik"
Berlin, DE

This document is a translation. The definitive version is the original German annex to the accreditation certificate. Testing field Standard / In-House Procedure / Version Title of Standard or In-House Procedure (Deviations / Mod

SLG Prüf- und Zertifizierungs
Hartmannsdorf, DE

Testing field Standard / In- House Procedure / Version Title of Standard or In-House Procedure (Deviations / Modifications of Standard) Test Range / Restrictions EM C DIN EN 60947 -4-1: 2014-02 Low -voltage switchgear and contro

IMA Materialforschung und Anwendungstechnik
Dresden, DE

IEC 60947-4-3:2014 Low-voltage switchgear and contr olgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads Electrical engineering VDE 0660 - 200:2010 DIN EN 60947-5-1:2018

TUV SUD America
New Brighton, MN, US

Test Technology: Test Method(s) 1,2: Immunity Generic Product Family Standards (cont.) EN 61547; IEC/EN 60730-1 (Sections 23 & 26); IEC/EN 60730-2-9 (Sections 23 & 26)

Siemens Aktiengesellschaft EMV Labor RBG S 10
Regensburg, DE
We don't know yet whether this lab takes outside work.

Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfbereich / Einschränkungen EMV IEC 60947 -4-1:2023 Low -voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters -

Sieć Badawcza Łukasiewicz - Instytut Mikroelektroniki i Fotoniki
Warszawa, PL
We don't know yet whether this lab takes outside work.

Przedmiot badań/wyrób Rodzaj działalności/badane cechy/metoda Dokumenty odniesienia Aparatura rozdzielcza i sterownicza Przekaźniki pomiarowe i urządzenia zabezpieczeniowe Emisja, napięcie zaburzeń ciągłych na zaciskach, przewodzonych

Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Warszawa, PL
We don't know yet whether this lab takes outside work.

IEC 60947-4-3:2014 [IDT] Graniczne przyrosty temperatury - nagrzewanie prądem do 10 kA Właściwości dielektryczne izolacji próby napięciem - udarowym do 25 kV - przemiennym 50 Hz do 5 kV Zdolność załączania i wyłączania do 63 kA AC

Diehl Aerospace
Überlingen, DE
We don't know yet whether this lab takes outside work.

IEC 60947-4-3 (2014) Niederspannungsschaltgeräte – Teil 4-3: Schütze und Motorstarter – Halbleiter-Steuergeräte und -Schütze für nichtmotorische Lasten für Wechselspannung Low-voltage switchgear and controlgear – Part 4-3: Contacto

Siemens Aktiengesellschaft AG SI EP EMS R&D TC3
Amberg, DE
We don't know yet whether this lab takes outside work.

IEC 60947-4-3 Edition 2.0, 2014-05 Low-voltage switchgear and controlgear- Part 4-3: AC semiconductor controllers and contactors for non-motor loads EN 60947-4-3 2014-06 Low-voltage switchgear and controlgear- Part 4-3: AC semi

Murrelektronik GmbH Prüfzentrum (4)
Oppenweiler, DE
We don't know yet whether this lab takes outside work.

IEC 60947-4-3:2014); Deutsche Fassung EN 60947-4-3:2014 Nur Abschnitt 8.3 9.4.1 EMV Prüflingsgröße: 1m x 1m EMV IEC 60947-4-3:2014-05 ed.2.0 Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC

TDK Electronics AG EMV-Labor
Regensburg, DE
We don't know yet whether this lab takes outside work.

IEC 60947-4-3 (2014) Low-voltage switchgear and controlgear – Part 4-3: Contactors and motor-starters – AC semiconductor controllers and contactors for non-motor loads EMC tests only (chapter 8.3 and 9.3.5) EMV DIN EN IEC 60974-1

Siemens Aktiengesellschaft DI FA DSP SYS TT 2
Erlangen, DE
We don't know yet whether this lab takes outside work.

IEC 60947-4-3:2014); Deutsche Fassung EN 60947-4-3:2014 Nur 8.3 und 9.4 EMV IEC 60947 -4-3:2014 Low -voltage switchgear and controlgear - Part 4 -3: Contactors and motor-starters - AC semiconductor controllers and contactors for non

Other parts

All parts on the series page →