Registers refreshed 2026-11-20.See refresh dates

ISO 16283-2 Accredited Testing Labs Worldwide

Part of a series

See all 80 labs worldwide for ISO 16283 (any part)

Part 1 (Airborne sound insulation): 78 labs · Part 2 (Impact sound insulation): 68 labs · Part 3 (Façade sound insulation): 56 labs

Go to the series ↑

68 accredited laboratories in 7 countries hold ISO 16283-2 in their accredited scope. We don't know yet whether 40 of them take outside work. Primary accreditors include Entidad Nacional de Acreditación, Deutsche Akkreditierungsstelle, United Kingdom Accreditation Service.

Total labs
68
Countries
7

Available in 7 Countries

Spain
31 labs
Germany
11 labs
United Kingdom
10 labs
Poland
9 labs
Finland
4 labs
Italy
2 labs
Sweden
1 lab

Sample labs

AB-EIC CONTROL REGLAMENTARIO
Madrid, ES

ISO 16283-2 Medida del aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 Emplazamientos desde los que se llevan a cabo activid

AAA INGENIERÍA BERSEN
Palmera, ES

ISO 16283-2 Medida de aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE EN ISO 16283-3 Nota: El laboratorio mantiene un listado controlado y

Zenner Engineers Acoustics and HVAC
FI

ISO 16283-2:2020 RTY:n suositus ääni-eristävyyden mittaamisesta 21.9.2009 Kenttätoimintaa Huonetilat Jälkikaiunta-ajan kenttämittaukset SFS-EN ISO 3382-2:2008 + cor 1:2009 SFS-EN ISO 354:2003 Kenttätoimintaa Äänilähteet Äänitehotasojen määr

ISEVAL, S.L. (ISEVAL BY LIFTINSTITUUT)
Torrent, ES

ISO 16283-2 Nota: El laboratorio mantiene un listado controlado y público de los Documentos Normativos que ha analizado y para los que ha concluido que dispone de la adecuada capacidad técnica. ENAC es firmante de los Acuerdos de Reco

Construction Performance Solutions
Ipswich, GB

ISO 16283-2:2020 Site BS EN ISO 717-2:2020 50 Hz to 5 KHz BS EN ISO 140-7:1998 (Withdrawn) BS EN ISO 717-2:1997 (Withdrawn) Site Rooms Field measurements of reverberation time Building Bulletin 93 – Version 17 Fe

TÜV Rheinland LGA Products
Nürnberg, DE

ISO 16283-2 Akustik - Messung der Schalldämmung in Gebäuden 2020-11 und von Bauteilen am Bau - Teil 2: Trittschalldämmung DIN EN ISO 16283-3 Akustik - Messung der Schalldämmung in Gebäuden 2016-09 und von Bauteilen am Bau - Teil 3: Fassaden

Building Analysis & Testing
Bristol, GB

ISO 16283-2:2020 BS EN ISO 717-2:2020 A END

Fraunhofer-Gesellschaft zur Förderung der angewandten Forschung eingetragener Verein Fraunhofer-Institut für Bauphysik
Stuttgart, DE

DIN EN ISO 10848 -1 2018-02 Akustik – Messung der Flankenübertragung von Luftschall, Trittschall und Schall von gebäudetechnischen Anlagen zwischen benachbarten Räumen im Prüfstand und am Bau – Teil 1: Rahmendokument DIN EN ISO 10

RISE Research Institutes of Sweden
Borås, SE

ISO 16283-2 Stegljudsapparat 0,5 -1 m/s 0,0064 m/s Ja 2 Nej Annex A Längd Intern metod; SP 2339 Större objekt såsom maskiner, riggar, robotar etc. Dimension upp till 200 x 200 x 200 m Ner till 0,01 mm +2,5 ppm Optisk koordinatbestämni

ift Rosenheim
Rosenheim, DE

Prüfart Prüfparameter innerhalb der Grenzen Schallprüfstand, Mehrkanalmesssystem, Schallquellen, Mikrophone etc. - Norm -Trittschallpegel L n Ln(dB) [0..100] DIN EN ISO 10140 -3 - bewerteter Norm - Trittschallpegel L n,w Ln,w

BSRIA Limited
Berkshire, GB

ISO 16283-2:2015 END

TÜV Rheinland Energy & Environment GmbH Messstelle für Immissionsschutz (Environmental Protection)
Köln, DE

DIN EN ISO 5349 -2 2015-12 Mechanische Schwingungen – Messung und Bewertung der Einwirkung von Schwingungen auf das Hand-Arm-System des Menschen – Teil 2: Praxisgerechte Anleitung zur Messung am Arbeitsplatz ISO 2631 -1 1997-0

ECOS DEL PISUERGA
Arroyo de la Encomienda, ES

ISO 16283-2 Medida de aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 Locales y recintos Medida del tiempo de reverberaci

OCA INSPECCIÓN, CONTROL Y PREVENCIÓN, S.A. (Unipersonal) (OCA GLOBAL)
Pozuelo de Alarcón, ES

ISO 16283-2 Medidas del aislamiento acústico al ruido aéreo de fachadas. (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 Locales y recintos Medida del tiempo de reverberaci

EKOLAB Sp. z o.o.
Kobylnica, PL

ISO 16283-2:2021-02 z wyłączeniem pkt. 7.2.3. oraz pkt. 7.4 PN-EN ISO 717-2:1999 PN-EN ISO 717-2:2021-06 Wersja strony: A

Akustix Sp. z o.o.
Przeźmierowo, PL

ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p. 7.4 PN-EN ISO 140-7:2000 PN-EN ISO 140-14:2006 Wskaźnik ważony poziomu uderzeniowego znormalizowanego L’n,w, i poziomu uderzeniowego wzorcowego L’nT,W oraz widmowy wskaźnik adaptac

Sharps Redmore Partnership Limited Trading as Sharps Redmore Acoustic Consultants
Ipswich, GB

ISO 16283-2:2020 BS EN ISO 717-2:1997 (Withdrawn) BS EN ISO 717-2:2013 (Withdrawn) BS EN ISO 717-2:2020 Building (Scotland) Regulations 2004. Technical Handbook (Domestic) 2022, Section 5 Noise. Technical Handbook (Non- Do

AUDIOTEC INGENIERÍA ACÚSTICA
Boecillo, ES

ISO 16283-2 I Locales y Recintos Medida del tiempo de reverberación UNE-EN ISO 3382-2 I Máquinas Determinación del nivel de potencia sonora: grado de ingeniería UNE-EN ISO 3744 I Determinación del nivel de potencia sonora: grado cont

BUREAU VERITAS INSPECCIÓN Y TESTING
Sant Cugat del Vallès, ES

ISO 16283-2 Nota: El laboratorio mantiene un listado controlado y público de los Documentos Normativos que ha analizado y para los que ha concluido que dispone de la adecuada capacidad técnica. ENAC es firmante de los Acuerdos de Recon

PRECOVER ACÚSTICA Y MEDIO AMBIENTE, S.L.P.
Valencia, ES

ISO 16283-2 UNE-EN ISO 140-7:1999 Medidas de aislamiento acústico al ruido aéreo de fachadas (Método global de altavoz) UNE-EN ISO 16283-3 UNE-EN ISO 140-5:1999 Locales y Recintos Medida del tiempo de reverberación UNE-EN ISO 3382-2

Acoustical Investigation & Research Organisation Ltd (AIRO)
Hertfordshire, GB

ISO 16283-2:2020 BS EN ISO 717-2:1997 (Withdrawn) BS EN ISO 717-2:2020 Building Bulletin 93 Feb 2015 Site END

APAVE INSPECTION SPAIN
Madrid, ES

ISO 16283-2 Medidas del aislamiento acústico al ruido aéreo de fachadas. (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 Locales y recintos Medida de tiempo de reverberac

Healthy Abode
Essex, GB

ISO 16283-2:2020 BS EN ISO 717-2:2020 Rooms Field measurements of reverberation time 50 Hz – 5 KHz Building Bulletin 93 – Version 17 Feb 2015 Tables 6 & 7 50 Hz – 5 KHz HTM 08-01 - 2013 50 Hz – 5 KHz BS EN ISO 338

Initivo Consultancy
Bedfordshire, GB

ISO 16283-2:2020 B FAÇADED AND FAÇADE ELEMENTS Laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms BS EN ISO 10848-2:2006 BS EN ISO 10848-2: 2017 BS EN ISO 10848-3:200

ECORICERCHE
Bassano del Grappa, IT

ISO 16283-2:2020 + UNI EN ISO 717-2:2021 Fonometria UNI EN ISO 16283-3:2016 + UNI EN ISO 717-1:2021 Fonometria UNI EN ISO 16283-1:2018 + UNI EN ISO 717-1:2021 Fonometria Denominazione della prova / Campi di prova Metodo di prova Tec

ACOUSTICS ANALYSIS
Berriozar, ES

ISO 16283-2 UNE-EN ISO 140-7:1999 Medida de aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 Nota: El laboratorio mantiene un

TÜV NORD Umweltschutz GmbH & Co. KG
Hamburg, DE

DIN EN ISO 10140 -3 2021-09 Akustik - Messung der Schalldämmung von Bauteilen im Prüfstand - Teil 3: Messung der Trittschalldämmung E DIN EN ISO 10140 -4 2021-09 Akustik – Messung der Schalldämmung von Bauteilen im Prüfstand

Sound Research Laboratories a trading name of SRL Technical Services
Suffolk, GB

ISO 16283-2:2020 Site Site Ducted silencers/attenuators Static Insertion Loss Total Pressure Loss Regenerated Noise of ducted silencers in the range 100 to 5000 Hz in 1/3 or 1/1 octave bands BS EN ISO 7235:2009 A

GiB Gesellschaft für innovative Bautechnologie mbH
Arnstorf, DE
We don't know yet whether this lab takes outside work.

This document is a translation. The definitive version is the original German annex to the accreditation certificate. DIN EN ISO 10848 -2 2018-02 Acoustics - Laboratory and field measurement of flanking transmission for airborne,

QUACER
Onda, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 Medida del aislamiento acústico al ruido aéreo de fachadas ( Método global del altavoz. Procedimiento con posiciones de micrófono fijas) UNE EN ISO 16283-3 Nota: El laboratorio mantiene un listado controlado y público

AISLAMIENTOS BURGALESES
Burgos, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 Medida de aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz . Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 Nota: El laboratorio mantiene un listado controlado y

Xella Technologie- und Forschungsgesellschaft mbH
Kloster Lehnin, DE
We don't know yet whether this lab takes outside work.

1. Messung der Schalldämmung in Gebäuden und an Bauteilen (A) DIN EN ISO 10140 -1 2016-12 Akustik - Messung der Schalldämmung von Bauteilen im Prüfstand – Teil 1: Anwendungsregeln für bestimmte Produkte DIN EN ISO 10140 -2 20

Instytut Techniki Budowlanej
Warszawa, PL
We don't know yet whether this lab takes outside work.

ISO 16283-2 Ściany wewnętrzne i ich elementy E Izolacyjność od dźwięków powietrznych pomiędzy pomieszczeniami Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda „In situ” * PN-EN ISO 16283-1 Ściany w

Wölfel Engineering GmbH + Co. KG
Höchberg, DE
We don't know yet whether this lab takes outside work.

ISO 16283-2 2020-11 Akustik – Messung der Schalldämmung in Gebäuden und von Bauteilen am Bau – Teil 2: Trittschalldämmung

SVANTEK Sp. z o.o.
Warszawa, PL
We don't know yet whether this lab takes outside work.

ISO 16283-2:2016-02 z wyłączeniem punktów 7.4 i 7.5 PN-EN ISO 717-2:1999 PN-EN ISO 717-2:2013-08 PN-EN ISO 717-2:2021-06 izolacyjność akustyczna od dźwięków uderzeniowych stropów (z obliczeń) Budynki i budowle – drgania Wartość

LABACUSTIC
Vall d Uixó, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 Medida del aislamiento al ruido aéreo de fachadas (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 Nota: El laboratorio mantiene un listado controlado y público de

LABORATORIO DE ACÚSTICA APLICADA DE LA UNIVERSIDAD DE LEÓN
León, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 UNE-EN ISO 140-7:1999 Medida del aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 UNE-EN ISO 140-5:1999 Locales y

SILENS SERVICIOS Y TECNOLOGÍA ACÚSTICA
Valencia, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 Medida del aislamiento acústico al ruido aéreo de fachadas. (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 Nota: El laboratorio mantiene un listado controlado y

Akukon
FI
We don't know yet whether this lab takes outside work.

ISO 16283-2:2020 ISO 140-7:1998 ISO 140-14:2004/Cor 1:2007 ISO 140-14:2004 ISO 717-2:2020 RTY Suositus äänieristävyyden mittaamisesta 21.9.2009 Helsinki, Riika, Tallinna, Vilna, Kenttätoimintaa Huonetilat Jälkikaiunta-ajan mittaukset, 50 H

Schalltechnisches Ingenieurbüro Pies
Boppard-Buchholz, DE
We don't know yet whether this lab takes outside work.

Flexibler Akkreditierungsbereich: Dem Prüflaboratorium ist, ohne dass es einer vorherigen Information und Zustimmung der DAkkS bedarf, die Anwendung der hier aufgeführten genormten oder ihnen gleichzusetzenden Prüfverfahren mit untersc

EDP Building Sciences a division of E.D.P. Health, Safety and Environment Consultants
Coventry, GB
We don't know yet whether this lab takes outside work.

ISO 16283-2:2018 (Withdrawn) BS EN ISO 16283-2:2020 END

LABORATORIO DE EVALUACIÓN Y CONTROL DEL RUIDO
Donostia-San Sebastián, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 Medida del aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 140-5:1999 UNE-EN ISO 16283-3 Nota: El laboratorio manti

CENTRO DE ESTUDIO Y CONTROL DE RUIDO
Boecillo, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 Edificios y elementos constructivos Medida del aislamiento acústico al ruido aéreo de fachadas. (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 Locales y recint

SONITUS Sp. z o.o. Sp.k.
Wrocław, PL
We don't know yet whether this lab takes outside work.

ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4 Wskaźnik ważony przybliżonego poziomu uderzeniowego znormalizowanego L’n,w, i wskaźnik ważony poziomu uderzeniowego wzorcowego L’nT,w oraz widmowy wskaźnik adaptacyjny CI (z obl

MARGARIDA AUDITORES ACUSTICOS, S.L. (Unipersonal) (Margarida)
Madrid, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 Locales y Recintos Medida del tiempo de reverberación UNE-EN ISO 3382-2 Nota: El laboratorio mantiene un listado controlado y público de los Documentos Normativos que ha analizado y para los que ha concluido que dispone

ACUSTICA Y TELECOMUNICACIONES, S.L. (SONOX)
Rótova, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 I Muestreo espacial y temporal de vibraciones Medida de vibraciones Anexo IV del Real Decreto 1367/2007 de 19 de octubre I Dispositivos reductores de ruido de tráfico en carreteras Comportamiento acústico: valores in

Mikołaj Kirpluk "NTL - M. Kirpluk"
Warszawa, PL
We don't know yet whether this lab takes outside work.

ISO 16283-2:2021-02 z wyłączeniem punktów 7.2.3 i, 7.4 i 13 Wskaźnik ważony poziomu uderzeniowego znormalizowanego L’n,w, i poziomu uderzeniowego wzorcowego L’nT,W oraz widmowy wskaźnik adaptacyjny CI (z obliczeń) PN-EN ISO 717-2

CALIDAD Y GESTIÓN CIENTÍFICA, S.L. (SIGGO)
Altea, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 Medida del aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 Locales y recintos Medida del tiempo de reverberación UN

SONORA TELECOMUNICACIONS, S.L.P.
Gandia, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 UNE-EN ISO 140-7:1999 Medida del aislamiento acústico al ruido aéreo de fachadas (Método Global del Altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-3 UNE-EN ISO 140-5:1999 Nota: E

EPTISA - CINSA INGENIERÍA Y CALIDAD
Basauri, ES
We don't know yet whether this lab takes outside work.

ISO 16283-2 Medida del aislamiento acústico a ruido aéreo de fachadas, Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas UNE-EN ISO 16283-3 Nota: El laboratorio mantiene un listado controlado y públ

Showing labs 1–50 of 68. Use pagination below to see more.