LABTOMIKA Spółka z ograniczoną odpowiedzialnością
ul. Sarnia 2/5, 52-129, Wrocław, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at LABTOMIKA Spółka z ograniczoną odpowiedzialnością?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 1931Active
Accredited standards
7Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidanceCertificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.
PN-83/E-04040.03; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
PN-83/E-04040.03; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
PN-83/E-04040.03; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PN-N-01307:1994; PN-EN ISO 9612:2011
PN-83/E-04040.03Name not checked yet
PN-83/E-04040.03; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
PN-Z-04008-7:2002Name not checked yet
PN-Z-04008-7:2002; PN-Z-04008-7:2002/Az1:2004; PB-1 wydanie 3 z dnia 24.02.2025 r.
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PN-N-01307:1994; PN-EN ISO 9612:2011
Scope as published by PCA
4 lines
ISO/IEC 17025
ActiveAB 1931
The scope document we hold says it is valid until 2029-04-08.
Accredited scope, certificate AB 1931
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | - | working environment (harmful factors - air); working environment (harmful and nuisance factors – noise, vibration, lighting) | - |
| 2 | chemical | PN-Z-04008-7:2002; PN-Z-04008-7:2002/Az1:2004; PB-1 wydanie 3 z dnia 24.02.2025 r. | Ambient air | 2.3 to 232 mg/m3 |
| 3 | environmental | PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PN-N-01307:1994; PN-EN ISO 9612:2011 | Ambient air | 0.13 to 136 dB; mg/m3 |
| 4 | environmental | PN-83/E-04040.03; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011 | Workplace environment | 0.03 to 8000 lx; m/s2; m/s² |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Zakład Wykonywania Pomiarów EMITOROpole · ~83 kmPCAShares 5 accredited methods and materialsPN-83/E-04040.03PN-Z-04008-7:2002PN-Z-04507:2022-05
- LAB-SERWIS Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek SierocińskiCzęstochowa · ~154 kmPCAShares 5 accredited methods and materialsPN-83/E-04040.03PN-Z-04008-7:2002PN-Z-04507:2022-05
- dB-lux Laboratorium Środowiska Pracy Spółka z ograniczoną odpowiedzialnością Spółka komandytowaChojnów · ~74 kmPCAShares 4 accredited methods and materialsPN-Z-04008-7:2002PN-Z-04507:2022-05Ambient air
- Eurofins SEPO Spółka z ograniczoną odpowiedzialnościąKnurów · ~156 kmPCAShares 4 accredited methods and materialsPN-83/E-04040.03PN-Z-04507:2022-05Ambient air
- Laboratorium Wibroakustyki i Ochrony Środowiska Bogdan KępskiŁódź · ~188 kmPCAShares 4 accredited methods and materialsPN-Z-04008-7:2002PN-Z-04507:2022-05Ambient air
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.