Registers refreshed 2026-11-20.See refresh dates
United States

Element U.S. Space & Defense

1536 East Valencia Drive, 92831, Fullerton, CA, United States

Visit website
A2LA 214.01A2LA 214.02A2LA 214.03and 2 moreISO/IEC 17025Register refreshed 2026-11-20
One of 4 sites of this organization in our directory. View the organizationPart of the Element Materials Technology group: 127 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
20
A2LA certificates
5
Sites in our directory
4
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 20 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60068 series10
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-7
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock

Certificate says EN 60068-2-27. Probably the same standard; not checked against the EN document.

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-56
IEC 60068-2-60
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-68
IEC4
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 60695-11-5
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

Certificate says EN 61000-4-2. Probably the same standard; not checked against the EN document.

ASTM3
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM D1149
ASTM D1171
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ISO 2685Aircraft - Environmental test procedure for airborne equipment - Resistance to fire in designated fire zones
ISO 7779Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment

Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.

Scope as published by A2LA

21 lines
A2LA

ISO/IEC 17025

Active

214.01

The scope document we hold says it is valid until 2028-03-31.

View scope
A2LA

ISO/IEC 17025

Active

214.02

The scope document we hold says it is valid until 2028-03-31.

View scope
A2LA

ISO/IEC 17025

Active

214.03

The scope document we hold says it is valid until 2028-03-31.

View scope
A2LA

ISO/IEC 17025

Active

214.04

The scope document we hold says it is valid until 2028-03-31.

View scope
A2LA

ISO/IEC 17025

Active

214.25

The scope document we hold says it is valid until 2028-03-31.

View scope

Location

1536 East Valencia Drive, Fullerton, CA, 92831, US

33.87082, -117.92942

Open in Maps

Other Locations

3 other sites in this organization

Accreditation data refreshed from the A2LA register on .