FindTestingLabs
Registers collected 2026-08-22.See collection dates
United States

Element U.S. Space & Defense

5325 Old Winter Garden Rd., 32811, Orlando, FL, United States

A2LA|214.46A2LA|214.47ISO/IEC 17025Register collected 2026-08-22
Certificates
2
Scope items
8
Locations
4
Watch this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Element U.S. Space & Defense?

Claim this profile to keep it accurate.

Claim this profile

Register record

A2LACollected
214.46Active
214.47Active

Certificates and scope

2
A2LA

ISO/IEC 17025

Active

214.46

View scope

Accredited scope, certificate 214.46

DisciplineMethodMatrixRange
mechanicalMIL-STD-810E/F/G/H, Method 505; MIL-STD-810E/F/G/H, Method 506; RTCA/DO-160E/F/G; MIL-STD-810E/F/G/H, Method 507; MIL-STD-202G/H, Method 106; MIL-STD-810E/F/G/H, Method 509; ASTM B117; MIL-STD-810E/F/G/H, Method 510; RTCA/DO-160E/F/G, Section 12.4; MIL-STD-810E/F/G/H, Method 511; MIL-STD-810E/F/G/H, Method 512; MIL-STD-810E/F/G/H, Method 513; RTCA/DO-160E/F/G, Section 7; MIL-STD-202G/H, Method 212; MIL-STD-810E/F/G/H, Method 514; MIL-STD-810E/F/G/H, Method 516; MIL-STD-202G/H, Method 213--
mechanicalMIL-STD-810E/F/G/H; RTCA/DO-160E/F/G; MIL-STD-202G/H--
mechanical---
mechanicalMIL-STD-810E/F/G/H, Method 516; MIL-STD-810E/F/G/H, Method 520; MIL-STD-810E/F/G/H, Method 521; MIL-STD-810E/F/G/H, Method 524; RTCA/DO-160E/F/G, Section 24; RTCA/DO-160E/F/G, Section 10; SAE ARP4378B; SAE ARP4946A; SAE ARP1383B/C--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

A2LA

ISO/IEC 17025

Active

214.47

View scope

Accredited scope, certificate 214.47

DisciplineMethodMatrixRange
mechanical---
mechanicalMIL-STD-810E/F/G/H; RTCA/DO-160E/F/G; MIL-STD-202G/H--
mechanicalMIL-STD-810E/F/G/H, Method 505; MIL-STD-810E/F/G/H, Method 506; RTCA/DO-160E/F/G; MIL-STD-810E/F/G/H, Method 507; MIL-STD-202G/H, Method 106; MIL-STD-810E/F/G/H, Method 509; ASTM B117; MIL-STD-810E/F/G/H, Method 510; RTCA/DO-160E/F/G; MIL-STD-810E/F/G/H, Method 511; MIL-STD-810E/F/G/H, Method 512; MIL-STD-810E/F/G/H, Method 513; MIL-STD-202G/H, Method 212; MIL-STD-810E/F/G/H, Method 514; MIL-STD-810E/F/G/H, Method 516; MIL-STD-202G/H, Method 213--
mechanicalMIL-STD-810E/F/G/H, Method 516; MIL-STD-810E/F/G/H, Method 520; MIL-STD-810E/F/G/H, Method 521; MIL-STD-810E/F/G/H, Method 524; RTCA/DO-160E/F/G, Section 24; RTCA/DO-160E/F/G, Section 10; SAE ARP4378B; SAE ARP4946A; SAE ARP1383B/C--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

Location

5325 Old Winter Garden Rd., Orlando, FL, 32811, US

28.54212, -81.37905

Open in Maps

Other Locations

3 other sites in this organization

Accreditation data collected from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.