Q-Lab Test Services, Florida
1005 SW 18th Ave., P.O. Box 349490, 33034, Homestead, FL, United States
Visit website- Accredited standards
- 123
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 123 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM89
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM C734
ASTM C1257
ASTM C1442
ASTM C1501
ASTM C1589
ASTM D522
ASTM D523Standard Test Method for Specular Gloss
ASTM D610
ASTM D660
ASTM D661
ASTM D662
Show all 89
ASTM D714
ASTM D772
ASTM D904
ASTM D968
ASTM D1003
ASTM D1006
ASTM D1014
ASTM D1435
ASTM D1654
ASTM D1729
ASTM D1735
ASTM D1925
ASTM D2244
ASTM D2247
ASTM D2248
ASTM D2565
ASTM D2616
ASTM D2794
ASTM D2803
ASTM D3170
ASTM D3274
ASTM D3359
ASTM D3363
ASTM D3424
ASTM D3456
ASTM D3679
ASTM D3719
ASTM D4060
ASTM D4138
ASTM D4141
ASTM D4214
ASTM D4226
ASTM D4303
ASTM D4329
ASTM D4355
ASTM D4459
ASTM D4585
ASTM D4587
ASTM D4674
ASTM D4726
ASTM D4798
ASTM D4799
ASTM D4803
ASTM D5071
ASTM D5208
ASTM D5272
ASTM D5894
ASTM D6551
ASTM D6675
ASTM D6695
ASTM D6864
ASTM D7091
ASTM D7251
ASTM D7334
ASTM D7356
ASTM D7376
ASTM D7793
ASTM D7856
ASTM D7869
ASTM E313
ASTM E1164
ASTM E1331
ASTM E1348
ASTM E1349
ASTM F1945
ASTM F2366
ASTM G7
ASTM G24
ASTM G50
ASTM G53
ASTM G85Exclusion
Limits written next to it
ASTM G85 (except A4) Modified Salt Spray (Fog) Testing
ASTM G147
ASTM G151
ASTM G154
ASTM G155
ASTM G201
ASTM G224
ISO14
ISO 877-1Plastics - Methods of exposure to solar radiation - Part 1: General guidance
ISO 877-2Plastics - Methods of exposure to solar radiation - Part 2: Direct weathering and exposure behind window glass
ISO 2178Non-magnetic coatings on magnetic substrates - Measurement of coating thickness - Magnetic method
ISO 2360Non-conductive coatings on non-magnetic electrically conductive base metals - Measurement of coating thickness - Amplitude-sensitive eddy-current method
ISO 2409Paints and varnishes - Cross-cut test
ISO 2810Paints and varnishes - Natural weathering of coatings - Exposure and assessment
ISO 2813Paints and varnishes - Determination of gloss value at 20°, 60° and 85°
ISO 3668Paints and varnishes - Visual comparison of colour of paints
ISO 4582Plastics - Determination of changes in colour and variations in properties after exposure to glass-filtered solar radiation, natural weathering or laboratory radiation sources
ISO 4628-1Paints and varnishes - Evaluation of degradation of coatings - Designation of quantity and size of defects, and of intensity of uniform changes in appearance - Part 1: General introduction and designation system
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 11341Paints and varnishes - Artificial weathering and exposure to artificial radiation - Exposure to filtered xenon-arc radiation
ISO 11507Paints and varnishes - Exposure of coatings to artificial weathering - Exposure to fluorescent UV lamps and water
ISO 20433Leather - Tests for colour fastness - Colour fastness to crocking
AATCC5
AATCC 8
AATCC 16
AATCC 169
AATCC 186
AATCC 1111
EN 13523 series4
EN 13523-4
EN 13523-8
EN 13523-10
EN 13523-19
ISO 105 series3
ISO 105-A02Textiles - Tests for colour fastness - Part A02: Grey scale for assessing change in colour
ISO 105-A03Textiles - Tests for colour fastness - Part A03: Grey scale for assessing staining
ISO 105-X12Textiles - Tests for colour fastness - Part X12: Colour fastness to rubbing
ISO 16474 series3
ISO 16474-1Paints and varnishes - Methods of exposure to laboratory light sources - Part 1: General guidance
ISO 16474-2Paints and varnishes - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps
ISO 16474-3Paints and varnishes - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps
ISO 4892 series3
ISO 4892-1Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance and requirements
ISO 4892-2Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps
ISO 4892-3Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps
Other standards2
EN 927-6
VDA 233
ASTM B117; ISO 9227; ASTM D7091; ISO 2178; ISO 2360; ASTM D1003; ASTM D2244; ISO 4582; ASTM D523; ISO 2813; AATCC EP1; AATCC EP2; ASTM D2616; ISO 105-A02; ISO 105-A03; ASTM D522; ASTM D3170; SAE J400; ASTM D7334; AATCC TM8; ISO 20433; ASTM D4138
ASTM D7793; ASTM D7856; EN 13523-19; FLTM BI 160-01; GMW 14873; GM 9163P; ISO 105 B01; ISO 877-1; ISO 877-2; ISO 2810; LP463-KB19-01; LP463-PB34-01; AATCC TM16.3; AATCC TM169; ASTM C734; ASTM C1257; ASTM C1442; ASTM C1501; ASTM D2565; ASTM D3424; ASTM D4303; ASTM D4355; ASTM D4459; ASTM D4798; ASTM D5071; ASTM D6551; ASTM D6695; ASTM D7356; ASTM D7869; ASTM D904; ASTM F2366; FLTM BO 116-01; ISO 16474-1; ISO 16474-2
ASTM D2248; ASTM D968 (Method A); ASTM D2794; ASTM D4803; FLTM BI 104-01; ASTM D3363; ASTM D4060; ASTM D3359; ISO 2409; AATCC TM 1111 3; AATCC TM16.1; ASTM C1589; ASTM D1006 3; ASTM D1014; ASTM D1435 3; ASTM D3424 (Method 1 & 2); ASTM D3456 3; ASTM D3679 3; ASTM D4141; ASTM D4303 (Method A & C); ASTM D4726 3; ASTM D5272 3; ASTM D6675; ASTM D6864 3; ASTM D7251 3
ASTM D1735; ASTM D2247; ASTM D2803; ASTM G85; EN 13523-8; FLTM BI 103-01; Ford TM-00.00-L-467; GMW 3286; GM 9505P; GMW14124; GMW 14729; GMW 14872; GMW 15282; GM 9511P; SAE J1959; SAE J2334; VDA 233-102; VW PV 1210; AATCC EP6; AATCC EP9; ASTM D610; ASTM D660; ASTM D661; ASTM D662; ASTM D714; ASTM D772; ASTM D1654; ASTM D1729; ASTM D1925-70; ASTM D3274; ASTM D3719-00; ASTM D4214; ASTM E313; ASTM E1164; ASTM E1331; ASTM E1348
ISO 11341; JIS D 0205; MIL-STD-810 Procedure II; SAE J2412; SAE J2527; VW PV 1306; VW PV 3929; VW PV 3930; AATCC TM186; ASTM D3424 (Method 8); ASTM D4329; ASTM D4585; ASTM D4587; ASTM D4674 (Method III & IV); ASTM D4799; ASTM D5208; ASTM D5894; ASTM F1945; ASTM G53-96; ASTM G224; EN 927-6; EN 13523-10; FLTM BI 104-02; ISO 11507; ISO 16474-3; SAE J2020
ASTM E1349; EN 13523 Part 2; EN 13523 Part 3; EN 13523 Part 4; EN 13523 Part 21; ISO 3668; ISO 4628 Part 1; ISO 4628 Part 2; ISO 4628 Part 3; ISO 4628 Part 4; ISO 4628 Part 5; ISO 4628 Part 6; ISO 4628 Part 7; ISO 4628 Part 8; ISO 4628 Part 10; SAE J1545; SAE J1767; ASTM D4226; FLTM BI 157-04; FLTM BI 157-06; GMW 14829; GM 9071P; GMW 14700; Volvo STD 1024,7132; AAMA 303; AAMA 305; AAMA 307; AAMA 308; AAMA 611; AAMA 612; AAMA 613; AAMA 614; AAMA 615
ASTM G7; ASTM G24; ASTM G50; ASTM D7376; Galvanotechnick 1/2006; SAE J576; SAE J1976; ASTM G201; GMW 3417; ASTM G155; ISO 4892-2; ASTM G154; ISO 4892-3
AAMA 623; AAMA 624; AAMA 625; AAMA 701/702; AAMA 2603; AAMA 2604; AAMA 2605; ASTM G147; ASTM G151; ISO 4892-1
Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.
Scope as published by A2LA
14 lines
ISO/IEC 17025
Active859.01
The scope document we hold says it is valid until 2028-06-30.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Element Materials Technology - MelbourneMelbourne, FL · ~290 kmA2LAShares 1 accredited test methodASTM B117
- Element U.S. Space & DefenseOrlando, FL · ~353 kmA2LAShares 1 accredited test methodASTM B117
- Architectural Testing, Inc. (An Intertek Company)Lithia Springs, GA · ~1,010 kmA2LAShares 1 accredited test methodASTM B117
- Durham Holdings Corporation dba MME TestingSuwanee, GA · ~1,015 kmA2LAShares 1 accredited test methodASTM B117
- MGA Research CorporationGreer, SC · ~1,066 kmA2LAShares 1 accredited test methodASTM B117
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.