Laboratorium Badań Środowiskowych Kilińska, Sampolska, Stępień Sp. j.
ul. Abrahama 15A, 80-307, Gdańsk, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Laboratorium Badań Środowiskowych Kilińska, Sampolska, Stępień Sp. j.?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 967Active
Accredited standards
10Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidanceCertificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.
PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004+A1:2015-11; PN-EN 14253+A1:2011
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004+A1:2015-11; PN-EN 14253+A1:2011
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004+A1:2015-11; PN-EN 14253+A1:2011
ISO 7243Ergonomics of the thermal environment - Assessment of heat stress using the WBGT (wet bulb globe temperature) index
PN-83/E-04040.03; PN-EN ISO 7730:2006/Ap2:2016-04; PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01
ISO 7730Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
PN-83/E-04040.03; PN-EN ISO 7730:2006/Ap2:2016-04; PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-87/B-02156; PN-Z-04008-7:2002+Az1:2004
ISO 11079Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effects
PN-83/E-04040.03; PN-EN ISO 7730:2006/Ap2:2016-04; PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01
PN-83/E-04040.03Name not checked yet
PN-83/E-04040.03; PN-EN ISO 7730:2006/Ap2:2016-04; PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-87/B-02156; PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; LBŚ-PB-7
Scope as published by PCA
5 lines
ISO/IEC 17025
ActiveAB 967
The scope document we hold says it is valid until 2028-11-06.
Accredited scope, certificate AB 967
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | mechanical | - | obiekty budowlane; środowisko pracy (czynniki szkodliwe - powietrze); środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie, mikroklimat) | - |
| 2 | environmental | PN-N-01307:1994; PN-EN ISO 9612:2011; PN-87/B-02156; PN-Z-04008-7:2002+Az1:2004 | Workplace environment | 44 to 136 dB |
| 3 | environmental | PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; LBŚ-PB-7 | Ambient air | 0.2 to 117 mg/m3; ppm |
| 4 | environmental | PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004+A1:2015-11; PN-EN 14253+A1:2011 | Workplace environment | 0.02 to 50 m/s2 |
| 5 | environmental | PN-83/E-04040.03; PN-EN ISO 7730:2006/Ap2:2016-04; PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01 | Workplace environment | 10 to 10000 lx |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- TES LABORATORIUM Spółka z ograniczoną odpowiedzialnościąWarszawa · ~288 kmPCAShares 6 accredited methods and materialsEN ISO 5349-1:2004PN-83/E-04040.03PN-N-01307:1994
- LAB-SERWIS Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek SierocińskiCzęstochowa · ~403 kmPCAShares 6 accredited methods and materialsEN ISO 5349-1:2004PN-83/E-04040.03PN-N-01307:1994
- Eurofins SEPO Spółka z ograniczoną odpowiedzialnościąKnurów · ~468 kmPCAShares 6 accredited methods and materialsEN ISO 5349-1:2004PN-83/E-04040.03PN-N-01307:1994
- ENVI-CHEM Badania Chemiczne i ŚrodowiskoweElbląg · ~49 kmPCAShares 5 accredited methods and materialsEN ISO 5349-1:2004PN-N-01307:1994PN-Z-04507:2022-05
- MILAB Czesław MisiunKoszalin · ~172 kmPCAShares 5 accredited methods and materialsPN-83/E-04040.03PN-N-01307:1994PN-Z-04507:2022-05
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.