Hewlett Packard Enterprise, Roseville Hardware Test & Compliance
8000 Foothills Boulevard, M/S 5603, 95747-5603, Roseville, CA, United States
Visit website- Accredited standards
- 16
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 16 standard numbers and the 11 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI5
ETSI EN 300 386
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-19
IEC4
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
CISPR3
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
CNS 15936identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
Other standards4
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
ISO 7779Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment
ISO 9296Acoustics - Declared noise emission values of information technology and telecommunications equipment
ETSI EN 300 386; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; KS X 3124; KS X 3125; KS X 3126; ISO 7779:2018; ISO 9296:1988; IEC 60950-1 Second Edition; UL 60950-1 Second Edition; CAN/CSA-C22.2 No. 60950-1-07 Second Edition; IEC 62368-1 Second Edition; IEC 62368-1 Third Edition; UL 62368-1 Second Edition; UL 62368-1 Third Edition; CAN/CSA-C22.2 No. 62368-1-14 Second Edition; CAN/CSA-C22.2 No. 62368-1-19 Third Edition; IEC 60950-1; UL 60950-1; CAN/CSA-C22.2 No. 60950-1
IEC 60950-1; UL 60950-1; CAN/CSA-C22.2 No. 60950-1; IEC 62368-1; UL/CSA 62368-1
47 CFR, Part 15 Subpart B (using ANSI C63.4:2014); CISPR 11; EN 55011; CISPR 11:2016; EN 55011:2016+A1:2017+A11:2020+A2:2021; CISPR 11:2010; EN 55011:2009+A1:2010; CISPR 22:2008; EN 55022:2010; CISPR 32; EN 55032; CAN-CSA CISPR 32:2017; CISPR 32:2015+COR1:2016+A1:2019; EN 55032:2015+AC:2016+A1:2020+A11:2020; ICES-003 Issue 7; VCCI-CISPR 32; CNS 13438:2006 (up to 6 GHz); QCVN 118:2018/BTTTT; KS C 9832; CNS 15936:2016; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2:2019+A1:2021+A2:2024; IEC 61000-3-2:2014; EN 61000-3-2:2014; IEC 61000-3-2:2009; EN 61000-3-2:2006 +A1:2008 +A2:2009; IEC 61000-3-3; EN 61000-3-3; IEC 61000-3-3:2013/AMD2:2021; EN 61000-3-3:2013+A1+A2:2021; IEC 61000-3-3:2013; EN 61000-3-3:2013; IEC 61000-3-3:2008; EN 61000-3-3:2008
ANSI C63.4:2014; FCC KDB 974614
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active923.01
The scope document we hold says it is valid until 2027-10-31.
Accredited scope, certificate 923.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | 47 CFR, Part 15 Subpart B (using ANSI C63.4:2014); CISPR 11; EN 55011; CISPR 11:2016; EN 55011:2016+A1:2017+A11:2020+A2:2021; CISPR 11:2010; EN 55011:2009+A1:2010; CISPR 22:2008; EN 55022:2010; CISPR 32; EN 55032; CAN-CSA CISPR 32:2017; CISPR 32:2015+COR1:2016+A1:2019; EN 55032:2015+AC:2016+A1:2020+A11:2020; ICES-003 Issue 7; VCCI-CISPR 32; CNS 13438:2006 (up to 6 GHz); QCVN 118:2018/BTTTT; KS C 9832; CNS 15936:2016; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2:2019+A1:2021+A2:2024; IEC 61000-3-2:2014; EN 61000-3-2:2014; IEC 61000-3-2:2009; EN 61000-3-2:2006 +A1:2008 +A2:2009; IEC 61000-3-3; EN 61000-3-3; IEC 61000-3-3:2013/AMD2:2021; EN 61000-3-3:2013+A1+A2:2021; IEC 61000-3-3:2013; EN 61000-3-3:2013; IEC 61000-3-3:2008; EN 61000-3-3:2008 | IT Equipment | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0923.01) 09/10/2025 Page 2 of 5
Test Technology: Test Method(s):
Immunity
Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2;
IEC 61000-4-2:2025; EN 61000-4-2:2025;
IEC 61000-4-2:2008; EN 61000-4-2:2009;
KS C 9610-4-2
Radiated Immunity
(80MHz-6GHz, 28V/m)
IEC 61000-4-3; EN 61000-4-3;
IEC 61000-4-3:2020; EN 61000-4-3:2020;
IEC 61000-4-3:2010;
EN 61000-4-3:2006 +A1:2008 +A2:2010;
KS C 9610-4-3
Electrical Fast Transient/Burst IEC 61000-4-4; EN 61000-4-4;
IEC 61000-4-4:2012; EN 61000-4-4:2012;
IEC 61000-4-4:2011; EN 61000-4-4:2004 +A1:2010;
IEC 61000-4-4:2004; EN 61000-4-4:2004;
KS C 9610-4-4
Surge IEC 61000-4-5; EN 61000-4-5;
IEC 61000-4-5:2017; EN 61000-4-5:2014+A1:2017;
IEC 61000-4-5:2005; EN 61000-4-5:2006;
KS C 9610-4-5
Conducted Immunity IEC 61000-4-6; EN 61000-4-6;
IEC 61000-4-6:2023; EN 61000-4-6:2023;
IEC 61000-4-6:2013; EN 61000-4-6:2014;
IEC 61000-4-6:2008; EN 61000-4-6:2009;
IEC 61000-4-6:2006; EN 61000-4-6:2007;
KS C 9610-4-6
Power Frequency Magnetic Fields IEC 61000-4-8; EN 61000-4-8;
IEC 61000-4-8:2009; EN 61000-4-8:2010;
KS C 9610-4-8
Voltage Dips and Interruptions IEC 61000-4-11; EN 61000-4-11;
IEC 61000-4-11:2020; EN 61000-4-11:2020;
IEC 61000-4-11:2004; EN 61000-4-11:2004;
KS C 9610-4-11
Generic/Product Family and
Industry Standards1
CISPR 35; EN 55035; KS C 9835;
CISPR 35:2016; EN 55035:2017+A11:2020;
CISPR 24; EN 55024;
CISPR 24:2015; EN 55024:2010 +A1:2016;
IEC 60601-1-2; EN 60601-1-2;
IEC 60601-1-2:2014+A1:2020;
EN 60601-1-2:2015+A1:2021+A11:2021;
KS C IEC 60601-1-2;
IEC 61326-1:2012;
IEC 61326-2-06:2012; | ||
| 3 | ETSI EN 300 386; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; KS X 3124; KS X 3125; KS X 3126; ISO 7779:2018; ISO 9296:1988; IEC 60950-1 Second Edition; UL 60950-1 Second Edition; CAN/CSA-C22.2 No. 60950-1-07 Second Edition; IEC 62368-1 Second Edition; IEC 62368-1 Third Edition; UL 62368-1 Second Edition; UL 62368-1 Third Edition; CAN/CSA-C22.2 No. 62368-1-14 Second Edition; CAN/CSA-C22.2 No. 62368-1-19 Third Edition; IEC 60950-1; UL 60950-1; CAN/CSA-C22.2 No. 60950-1 | - | - |
| 4 | IEC 60950-1; UL 60950-1; CAN/CSA-C22.2 No. 60950-1; IEC 62368-1; UL/CSA 62368-1 | - | - |
| 5 | ANSI C63.4:2014; FCC KDB 974614 | - | to 40000 MHz |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
HEWLETT PACKARD ENTERPRISE,
ROSEVILLE HARDWARE TEST & COMPLIANCE
Roseville, CA
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 10th day of September 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 0923.01
Valid to October 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- CETECOMMilpitas, CA · ~154 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- HCT AmericaMilpitas, CA · ~156 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Intertek Testing Services NAMenlo Park, CA · ~164 kmA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 62368-1
- Vista Laboratories, Inc.San Clemente, CA · ~678 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- ElectroMagnetic InvestigationsHillsboro, OR · ~766 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.