Główny Inspektorat Ochrony Środowiska
Al. IX Wieków Kielc 3, 25-516, Kielce, Poland
- Accredited standards
- 22
- PCA certificate
- 1
- Sites in our directory
- 16
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 22 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO15
ISO 5667-6Water quality - Sampling - Part 6: Guidance on sampling of rivers and streams
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6878Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method
ISO 7150-1Water quality - Determination of ammonium - Part 1: Manual spectrometric method
ISO 9377-2Water quality - Determination of hydrocarbon oil index - Part 2: Method using solvent extraction and gas chromatography
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10381-5Soil quality - Sampling - Part 5: Guidance on the procedure for the investigation of urban and industrial sites with regard to soil contamination
ISO 10390Soil, treated biowaste and sludge - Determination of pH
ISO 10523Water quality - Determination of pH
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 17289Water quality - Determination of dissolved oxygen - Optical sensor method
ISO 17892-4Geotechnical investigation and testing - Laboratory testing of soil - Part 4: Determination of particle size distribution
ISO 17892-11Geotechnical investigation and testing - Laboratory testing of soil - Part 11: Permeability tests
EN7
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 1899-2Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 2: Method for undiluted samples
EN 15216Environmental solid matrices - Determination of total dissolved solids (TDS) in water and eluates
EN 25663Water quality - Determination of Kjeldahl nitrogen - Method after mineralization with selenium
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
PN-EN ISO 5667-6:2016-12; PN-77/C-04584; PN-ISO 5667-10:2021-11; PN-EN ISO 10523:2012; PN-EN 27888:1999; ISO 17289:2014; PN-ISO 10381-5:2009; PN-EN ISO 10390:2022-09
PN-EN 26777:1999; PN-EN 25663:2001; PN-73/C-04576/14; PN-EN ISO 5815-1:2019-12; PN-EN 1899-2:2002; PN-ISO 15705:2005 z wyłączeniem pkt.10.3; PN-EN ISO 10304-1:2009+AC:2012; PN-EN ISO 11885:2009; PB-01/KI wydanie 2 z dnia 09.12.2024 r.; PN-EN 15216:2022-03
PN-EN ISO 9377-2:2003; PN-EN ISO 6878:2006; PN-EN 872:2007; PN-EN 1484:1999; PN-ISO 7150-1:2002; PN-EN ISO 17892-11:2019-05; PN-EN ISO 17892-4:2017-01; PB-04/KI
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
5 lines
ISO/IEC 17025
ActiveAB 106
The scope document we hold says it is valid until 2027-04-07.
Accredited scope, certificate AB 106
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | WaterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 106
Scope of accreditation No. AB 106
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 106
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 29 z/of 26.02.2025
KIEROWNIK DZIAŁU AKREDYTACJI
BADAŃ EMISJI W ŚRODOWISKU
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 106 z dnia 07.01.2026 r.
Cykl akredytacji od 15.03.2023 r. do 07.04.2027 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 106 of 07.01.2026
Accreditation cycle from 15.03.2023 to 07.04.2027
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 29, 26.02.2025 1/6
Nazwa i adres / Name and address
GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA
ul. Chmielna 132/134
00-805 Warszawa
CENTRALNE LABORATORIUM BADAWCZE
ODDZIAŁ W KIELCACH
Al. IX Wieków Kielc 3
25-516 Kielce
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
C/28/P
C/30/P
G/34
N/28/P
N/30/P
N/31/P
N/31
Badania chemiczne i pobieranie próbek wody / Chemical tests and sampling of water
Badania chemiczne i pobieranie próbek ścieków / Chemical tests and sampling of sewage
Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki
fizyczne - hałas, pole elektromagnetyczne) / Tests concerning environmental engineering (environmental
and climatic) – general environment (physical factors – noise, electromagnetic field)
Badania właściwości fizycznych i pobieranie próbek wody / Tests of physical properties and sampling of
water
Badania właściwości fizycznych i pobieranie próbek ścieków / Tests of physical properties and sampling of
sewage
Badania właściwości fizycznych i pobieranie próbek gleby / Tests of physical properties and sampling of soil
Badania właściwości fizycznych gruntów / Tests of physical properties of ground
Wersja strony / Page version: B
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB-07, available at PCA website www.pca.gov.pl
AB 106 | - |
| 2 | Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F; Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | General environment | 1 to 30000 V/m |
| 3 | PN-EN ISO 5667-6:2016-12; PN-77/C-04584; PN-ISO 5667-10:2021-11; PN-EN ISO 10523:2012; PN-EN 27888:1999; ISO 17289:2014; PN-ISO 10381-5:2009; PN-EN ISO 10390:2022-09 | Water | 0 to 50 0C |
| 4 | PN-EN 26777:1999; PN-EN 25663:2001; PN-73/C-04576/14; PN-EN ISO 5815-1:2019-12; PN-EN 1899-2:2002; PN-ISO 15705:2005 z wyłączeniem pkt.10.3; PN-EN ISO 10304-1:2009+AC:2012; PN-EN ISO 11885:2009; PB-01/KI wydanie 2 z dnia 09.12.2024 r.; PN-EN 15216:2022-03 | Woda, ścieki | See scope document |
| 5 | PN-EN ISO 9377-2:2003; PN-EN ISO 6878:2006; PN-EN 872:2007; PN-EN 1484:1999; PN-ISO 7150-1:2002; PN-EN ISO 17892-11:2019-05; PN-EN ISO 17892-4:2017-01; PB-04/KI | Water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
15 other sites in this organization
Labs with overlapping accredited scope in Poland
- Centrum Badań Środowiska "SORBCHEM"Ruda Śląska · ~142 kmPCAShares 3 accredited methods and materialsEN 26777:1999EN ISO 9377-2:2003Water
- ORLEN Laboratorium S.A.Płock · ~195 kmPCAShares 3 accredited methods and materialsEN 26777:1999EN ISO 9377-2:2003Water
- LabStar Mateusz OlejnikStargard · ~470 kmPCAShares 3 accredited methods and materialsEN 26777:1999ISO 5667-6:2016-12Water
- Przedsiębiorstwo Naukowo-Techniczne "EKOTERRA"Kielce · ~3 kmPCAShares 2 accredited materialsGeneral environmentWater
- Zakład Usług Technicznych "ZUT" S.C. Bożena i Waldemar SzleperCzęstochowa · ~106 kmPCAShares 2 accredited materialsGeneral environmentWater
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.