Electrical Test Instruments
8430 Spires Way, Suites A - F, 21701, Frederick, MD, United States
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 5636.01 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1025 V |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.01) Revised 10/20/2025 Page 2 of 5
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Current3 – Measure
(0.1 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
18 µA/A + 1.8 nA
25 µA/A + 0.3 µA
2 µA/A + 0.32 µA
49 µA/A + 0.83 µA
130 µA/A + 11 µA
Keysight 3458A
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3 – Generate
(0 to 202) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
(30 to 45) Hz
45 Hz to 1 kHz
(1 to 40) kHz
(40 to 100) kHz
(30 to 45) Hz
45 Hz to 1 kHz
740 µV/V + 15 µV
310 µV/V + 15 µV
250 µV/V + 28 µV
430 µV/V + 40 µV
650 µV/V + 180 µV
210 µV/V + 120 µV
260 µV/V + 180 µV
800 µV/V + 300 µV
620 µV/V + 1.6 mV
280 µV/V + 1.0 mV
260 µV/V + 1.6 mV
750 µV/V + 3.0 mV
600 µV/V + 20 mV
190 µV/V + 12 mV
400 µV/V + 30 mV
2.3 mV/V + 50 mV
910 µV/V + 200 mV
330 µV/V + 60 mV
Transmille 4010
AC Voltage3 – Measure
(10 to 100) mV
100 mV to 1 V
10 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
10 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
310 µV/V + 38 µV
320 µV/V + 16 µV
1.1 mV/V + 25 µV
5.2 mV/V + 71 µV
7.7 mV/V + 33 µV
76 µV/V + 54 µV
150 µV/V + 40 µV
300 µV/V + 68 µV
840 µV/V + 0.12 mV
2.8 mV/V + 0.82 mV
Keysight 3458A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.01) Revised 10/20/2025 Page 3 of 5
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3 – Measure
(cont)
(1 to 10) V
(10 to 100) V
(100 to 750) V
10 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
10 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
40 Hz to 1 kHz
76 µV/V + 0.54 mV
150 µV/V + 0.39 mV
310 µV/V + 0.58 mV
830 µV/V + 1.2 mV
3.1 mV/V + 4.6mV
210 µV/V + 6.9 mV
210 µV/V + 5.6 mV
380 µV/V + 6.4 mV
1200 µV/V + 16 mV
4100 µV/V + 58 mV
410 µV/V + 0.07 mV
Keysight 3458A
AC Current3 – Generate
(20 to 202) µA
(0.2 to 2.02) mA
(2 to 20.2) mA
(20 to 202) mA
(0.2 to 2.02) A
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 30) kHz
2.5 mA/A + 0.25 µA
0.94 mA/A + 0.15 µA
9.8 mA/A + 0.25 µA
19 mA/A + 0.4 µA
2.9 mA/A + 0.25 µA
0.74 mA/A + 0.2 µA
5.8 mA/A + 0.3 µA µA
12 mA/A + 0.6 µA
2.2 mA/A + 3 µA
0.4 mA/A + 2 µA
2.8 mA/A + 3 µA
5.8 mA/A + 4 µA
2.4 mA/A + 30 µA
0.5 mA/A + 30 µA
5.7 mA/A + 40 µA
8.5 mA/A + 0.32 mA
2.3 mA/A + 0.3 mA
0.74 mA/A + 0.2 mA
6.9 mA/A + 1 mA
29 mA/A + 5 mA
Transmille 4010 | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.01) Revised 10/20/2025 Page 4 of 5
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current3 – Measure
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(20 to 45) Hz
100 Hz to 5 kHz
1.3 mA/A + 24 µA
0.67 mA/A + 23 µA
3.3 mA/A + 23 µA
4.4 mA/A + 23 µA
4.1 mA/A + 28 µA
1.6 mA/A + 25 µA
0.6 mA/A + 24 µA
1.3 mA/A + 23 µA
4.2 mA/A + 69 µA
1.6 mA/A + 40 µA
0.63 mA/A + 30 µA
0.31 mA/A + 27 µA
1.7 mA/A + 0.21 mA
0.89 mA/A + 0.31 mA
Keysight 3458A
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Resistance3 –
Generate
(0 to 100) Ω
(100 to 330) Ω
330Ω to 1kΩ
(1.0 to 3.3) kΩ
(3.3 to 10) kΩ
(10 to 33) kΩ
(33 to 100) kΩ
(100 to 330) kΩ
330kΩ to 1MΩ
(1.0 to 3.3) MΩ
(3.3 to 10) MΩ
0.41 mΩ/Ω + 78 mΩ
0.13 mΩ/Ω + 78 mΩ
0.12 mΩ/Ω + 78 mΩ
0.11 mΩ/Ω + 78 mΩ
0.13 mΩ/Ω + 78 mΩ
0.12 mΩ/Ω + 78 mΩ
0.13 mΩ/Ω + 78 mΩ
0.12 mΩ/Ω + 78 mΩ
0.13 mΩ/Ω + 78 mΩ
0.18 mΩ/Ω + 78 mΩ
0.16 mΩ/Ω + 78 mΩ
Transmille 4010
(Includes additional
50mΩ added to floor
as specified for all
ranges up to 33 MΩ.
DC Resistance3 –
Measure
(0 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
0.52 mΩ/Ω + .58
mΩ
16 µΩ/Ω + 81 mΩ
5.4 µΩ/Ω + 96 mΩ
15 µΩ/Ω + 28 mΩ
24 µΩ/Ω + 28 mΩ
89 µΩ/Ω + 28 mΩ
Keysight 3548A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.01) Revised 10/20/2025 Page 5 of 5
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Circuit Breaker Tester3
Time – Measure
(0 to 1) s
(1 to 10) s
3.1 ms
3.1 ms
Circuit breaker tester
analyzer BTSA-3
BTS Circuit Breaker
Tester Analyzer –
Measuring Equipment
Frequency – Measure
Analyzer Time
Timer Side Function
5 Hz
<1 s
>10 s
10 s
1 s
60 s
0.59 Hz
12 ms
8.9 ms
3.1 ms
3.1 ms
3.1 ms
53181A Counter
__________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavi or of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., r esolution,
repeatability) must also be considered and this, on its own, could result in the actual measurement
uncertainty achievable on a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 6 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Automated PrecisionRockville, MD · ~43 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - Washington D.C.Sterling, VA · ~46 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Baltimore, MDSparks, MD · ~67 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- American Scale & EquipmentBaltimore, MD · ~81 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Morehouse Instrument CompanyYork, PA · ~84 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.