Electrical Test Instruments

8430 Spires Way, Suites A - F, 21701, Frederick, MD, United States

Visit website
A2LA 5636.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 5636.01 · 6 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 1025 V
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.01) Revised 10/20/2025 Page 2 of 5 Parameter/Equipment Range CMC2, 4 (±) Comments DC Current3 – Measure (0.1 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 18 µA/A + 1.8 nA 25 µA/A + 0.3 µA 2 µA/A + 0.32 µA 49 µA/A + 0.83 µA 130 µA/A + 11 µA Keysight 3458A Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3 – Generate (0 to 202) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz (30 to 45) Hz 45 Hz to 1 kHz (1 to 40) kHz (40 to 100) kHz (30 to 45) Hz 45 Hz to 1 kHz 740 µV/V + 15 µV 310 µV/V + 15 µV 250 µV/V + 28 µV 430 µV/V + 40 µV 650 µV/V + 180 µV 210 µV/V + 120 µV 260 µV/V + 180 µV 800 µV/V + 300 µV 620 µV/V + 1.6 mV 280 µV/V + 1.0 mV 260 µV/V + 1.6 mV 750 µV/V + 3.0 mV 600 µV/V + 20 mV 190 µV/V + 12 mV 400 µV/V + 30 mV 2.3 mV/V + 50 mV 910 µV/V + 200 mV 330 µV/V + 60 mV Transmille 4010 AC Voltage3 – Measure (10 to 100) mV 100 mV to 1 V 10 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 310 µV/V + 38 µV 320 µV/V + 16 µV 1.1 mV/V + 25 µV 5.2 mV/V + 71 µV 7.7 mV/V + 33 µV 76 µV/V + 54 µV 150 µV/V + 40 µV 300 µV/V + 68 µV 840 µV/V + 0.12 mV 2.8 mV/V + 0.82 mV Keysight 3458A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.01) Revised 10/20/2025 Page 3 of 5 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3 – Measure (cont) (1 to 10) V (10 to 100) V (100 to 750) V 10 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 40 Hz to 1 kHz 76 µV/V + 0.54 mV 150 µV/V + 0.39 mV 310 µV/V + 0.58 mV 830 µV/V + 1.2 mV 3.1 mV/V + 4.6mV 210 µV/V + 6.9 mV 210 µV/V + 5.6 mV 380 µV/V + 6.4 mV 1200 µV/V + 16 mV 4100 µV/V + 58 mV 410 µV/V + 0.07 mV Keysight 3458A AC Current3 – Generate (20 to 202) µA (0.2 to 2.02) mA (2 to 20.2) mA (20 to 202) mA (0.2 to 2.02) A (10 to 45) Hz 45 Hz to 1 kHz (1 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 10) kHz (10 to 30) kHz 2.5 mA/A + 0.25 µA 0.94 mA/A + 0.15 µA 9.8 mA/A + 0.25 µA 19 mA/A + 0.4 µA 2.9 mA/A + 0.25 µA 0.74 mA/A + 0.2 µA 5.8 mA/A + 0.3 µA µA 12 mA/A + 0.6 µA 2.2 mA/A + 3 µA 0.4 mA/A + 2 µA 2.8 mA/A + 3 µA 5.8 mA/A + 4 µA 2.4 mA/A + 30 µA 0.5 mA/A + 30 µA 5.7 mA/A + 40 µA 8.5 mA/A + 0.32 mA 2.3 mA/A + 0.3 mA 0.74 mA/A + 0.2 mA 6.9 mA/A + 1 mA 29 mA/A + 5 mA Transmille 4010
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.01) Revised 10/20/2025 Page 4 of 5 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current3 – Measure (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (20 to 45) Hz 100 Hz to 5 kHz 1.3 mA/A + 24 µA 0.67 mA/A + 23 µA 3.3 mA/A + 23 µA 4.4 mA/A + 23 µA 4.1 mA/A + 28 µA 1.6 mA/A + 25 µA 0.6 mA/A + 24 µA 1.3 mA/A + 23 µA 4.2 mA/A + 69 µA 1.6 mA/A + 40 µA 0.63 mA/A + 30 µA 0.31 mA/A + 27 µA 1.7 mA/A + 0.21 mA 0.89 mA/A + 0.31 mA Keysight 3458A Parameter/Equipment Range CMC2, 4 (±) Comments DC Resistance3 – Generate (0 to 100) Ω (100 to 330) Ω 330Ω to 1kΩ (1.0 to 3.3) kΩ (3.3 to 10) kΩ (10 to 33) kΩ (33 to 100) kΩ (100 to 330) kΩ 330kΩ to 1MΩ (1.0 to 3.3) MΩ (3.3 to 10) MΩ 0.41 mΩ/Ω + 78 mΩ 0.13 mΩ/Ω + 78 mΩ 0.12 mΩ/Ω + 78 mΩ 0.11 mΩ/Ω + 78 mΩ 0.13 mΩ/Ω + 78 mΩ 0.12 mΩ/Ω + 78 mΩ 0.13 mΩ/Ω + 78 mΩ 0.12 mΩ/Ω + 78 mΩ 0.13 mΩ/Ω + 78 mΩ 0.18 mΩ/Ω + 78 mΩ 0.16 mΩ/Ω + 78 mΩ Transmille 4010 (Includes additional 50mΩ added to floor as specified for all ranges up to 33 MΩ. DC Resistance3 – Measure (0 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ 0.52 mΩ/Ω + .58 mΩ 16 µΩ/Ω + 81 mΩ 5.4 µΩ/Ω + 96 mΩ 15 µΩ/Ω + 28 mΩ 24 µΩ/Ω + 28 mΩ 89 µΩ/Ω + 28 mΩ Keysight 3548A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.01) Revised 10/20/2025 Page 5 of 5 Parameter/Equipment Range CMC2, 4 (±) Comments Circuit Breaker Tester3 Time – Measure (0 to 1) s (1 to 10) s 3.1 ms 3.1 ms Circuit breaker tester analyzer BTSA-3 BTS Circuit Breaker Tester Analyzer – Measuring Equipment Frequency – Measure Analyzer Time Timer Side Function 5 Hz <1 s >10 s 10 s 1 s 60 s 0.59 Hz 12 ms 8.9 ms 3.1 ms 3.1 ms 3.1 ms 53181A Counter __________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavi or of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., r esolution, repeatability) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
6ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

8430 Spires Way, Suites A - F, Frederick, MD, 21701, US

39.41578, -77.41276

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.