A2LA certificate 3128.01 · 26 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 | - | 0.5 to 2 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 2 of 25
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
W-CDMA TRx/Performance Test
System (ME7873F)3 – (cont)
RACH Measurement Accuracy
(Relative Level Measurement):
(0.5 to 2) GHz
Modulation
DPCCH Measurement Accuracy:
(0.5 to 2) GHz
Modulation
TX Spurious Measurement
Accuracy (General) CW:
TX Spurious Measurement
Accuracy (Additional) CW:
GSM
PHS
DL Band
RX Spurious Measurement
Accuracy (General) CW:
RX Spurious Measurement
Accuracy (Additional) CW:
In Band
GSM
Spectrum Emission Mask CW
Power Difference
8.4.4 (UL)
8.7.9 (UL)
8.7.9 (UL)
(0.15 to 10) MHz
(10 to 2200) MHz
(2.2 to 4) GHz
(4 to 12.75) GHz
(921 to 925) MHz
(925 to 960) MHz
(1805 to 1880) MHz
(1884.5 to 1919.6) MHz
Band I, II, III, IV, V, VII,
VIII, IX, XI; 800 MHz
(30 to 1000) MHz
(1 to 2.2) GHz
(2.2 to 4) GHz
(4 to 13) GHz
(0.5 to 2) GHz
(921 to 925) MHz
(925 to 960) MHz
(0.5 to 2) GHz CW
0.01 dB
0.30 dB
0.30 dB
0.30 dB
0.27 dB
0.32 dB
0.61 dB
1.2 dB
0.30 dB
0.31 dB
0.31 dB
0.30 dB
0.33 dB
0.30 dB
0.32 dB
0.61 dB
1.2 dB
0.33 dB
0.30 dB
0.30 dB
0.27 dB
Signal analyzer,
signal generator,
power meter &
power sensor,
calibration receiver | ||
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 3 of 25
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
W-CDMA TRx/Performance
Test System (ME7873F)3 –
(cont)
Adjacent Channel Leakage
Power Ratio (ACLR)
Occupied Bandwidth (OBW)
Modulation
Frequency Error Modulation
Error Vector Magnitude
(EVM):
(0.5 to 2) GHz
Modulation
Phase Error:
Peak Code Domain Error:
DL Output Accuracy:
(0.5 to 3) GHz
Modulation:
Downlink Power
Ior/Ioc (TRx):
(0.5 to 3) GHz
Modulation
(0.5 to 2) GHz,
Modulation/CW
(0.5 to 2) GHz
(0.5 to 2) GHz
ULRMC12k
Pre1f
(0.5 to 2) GHz
Modulation
(0.5 to 2) GHz
Modulation
(-30 to 0) dBm
(-80 to -30) dBm; Ioc
(MBMS)
(-120 to -80) dBm
Blocking (In-Band),
Spurious
Max Input
DPCCH_Ec/Ioc
Ior/Ioc
Ioc
0.43 dB
21 kHz
0.02 Hz
0.66 % of full scale
0.66 % of full scale
0.23 °
0.12 dB
0.32 dB
0.37 dB
0.45 dB
0.26 dB
0.09 dB
0.09 dB
0.34 dB
Signal analyzer,
signal generator,
power meter &
power sensor,
calibration receiver | 0.5 to 3 GHz |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 4 of 25
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
W-CDMA TRx/Performance
Test System (ME7873F)3 –
(cont)
Ior/Ioc (Perf):
(0.5 to 3) GHz
Modulation
Ior/Ioc (RRM Fading Test
Case) PropSimC2:
(0.5 to 3) GHz
Modulation
Ior/Ioc (RRM Fading Test
Case) MF6900A:
(0.5 to 3) GHz
Modulation
RRM Signal Output:
(0.5 to 3) GHz
Modulation
Ior/Ioc(Static)
Ior/Ioc(Static)[Sqrt(0.3^2 (Static)
+ 0.3^2(Static)]
Ioc
Fading
Ior/Ioc[Sqrt(0.3^2 (Static) +
0.5^2(Fading)]
Ior/Ioc[Sqrt(0.3^2 (Static) +
0.5^2(Fading) + 0.5^2 (Fading)]
Ior/Ioc[3000·Average]
Ioc
Ior
Ior1/Ior^2
Ioc
Ior
Ior, Ioc, RXLEV
Ior/Ioc, Ior/Ior, Ioc/Ioc
Ioc/RXLEV, Ioc/RXLEV (8.7.3A),
Ior/Ior (Inter Band), Ioc/Ioc (Inter
Band), Ioc/RXLEV (Ior & Ioc are
Combined in Digital Baseband
oSFS)
RXLEV/RXLEV
0.09 dB
0.12 dB
0.30 dB
0.09 dB
0.12 dB
0.15 dB
0.10 dB
0.31 dB
0.31 dB
0.09 dB
0.28 dB
0.29 dB
0.28 dB
0.09 dB
0.12 dB
0.39 dB
Signal analyzer,
signal
generator,
power meter &
power sensor,
calibration
receiver | 0.5 to 3 GHz |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 5 of 25
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
W-CDMA TRx/Performance
Test System (ME7873F)3 –
(cont)
CW Interference
Modulation Interference:
(0.5 to 3) GHz
Modulation
GSM Interference:
(0.5 to 3) GHz
Modulation
Blocking: (10 to 3000) MHz
Blocking: (3 to 8) GHz
Blocking: (8 to 13) GHz
RX IM
TX IM
SG2->CpDSG->Isolator-
>Antenna
SG2->Isolator->Antenna
Intermodulation
Characteristics
Blocking Characteristics
(Narrow Band)
Intermodulation
Characteristics
(Narrow Band)
0.26 dB
0.54 dB
1.1 dB
0.26 dB
0.26 dB
0.29 dB
0.29 dB
0.26 dB
0.29 dB
0.26 dB
Signal analyzer, signal
generator, power meter
& power sensor,
calibration receiver | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 6 of 25
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
RF Conformance Test System
(ME78xx7)3 –
UL Measurement Accuracy:
Carrier Aggregation
UL Measurement Accuracy:
Max Output
Frequency Error
Error Vector Magnitude (EVM)
Origin Offset
In Band Emission
In Band Emission for CA
Occupied Bandwidth (OBW)
Spectrum Emission Mask
Adjacent Channel Leakage
Power Ratio (ACLR)
Spectrum Flatness
Spurious, CW
Max Output, Min Output,
Off Power, TX IM (UL),
TX IM (IM)
(0.5 to 3) GHz
Modulation, CW
Up to 3 GHz
(3 to 4) GHz
(4 to 6) GHz
For Low Level WCDMA UL
(5.4.1, 8.4.2.xx
7)
(5.4.3, 5.5.1, 5.5.2)
(0.5 to 6) GHz Modulation
(0.5 to 6) GHz Modulation
(0.5 to 3) GHz Modulation
(0.5 to 6) GHz Modulation
(0.5 to 3) GHz Modulation
(0.5 to 6) GHz, CW
(0.5 to 3) GHz Modulation, CW
(3 to 4) GHz Modulation, CW
(4 to 6) GHz Modulation, CW
(0.5 to 4) GHz Modulation
(4 to 6) GHz Modulation
(0.5 to 6) GHz Modulation
(10 to 30) MHz
(30 to 4000) MHz
(4 to 13) GHz
(13 to 19) GHz
(19 to 26) GHz
0.37 dB
0.26 dB
0.30 dB
0.35 dB
0.38 dB
0.32 dB
1.2 Hz
0.21 % of full
scale
0.44 dB
0.27 dB
0.29 dB
0.01 kHz
0.27 dB
0.45 dB
0.37 dB
0.30 dB
0.43 dB
0.60 dB
0.29 dB
0.31 dB
0.48 dB
0.52 dB
0.60 dB
Signal
analyzer, signal
generator,
power meter &
power sensor | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 7 of 25
Parameter/Equipment
Frequency
CMC2, 4 (±)
Comments
RF Conformance Test System
(ME78xx7)3 (cont)
DL Output Accuracy:
Bandwidth: 1.4 MHz
Bandwidth: 20 MHz
DL Output Accuracy (RRM):
LTE Absolute
AWGN Absolute
W-CDMA Absolute
GSM Absolute
Memory Synthesizing Function
Output
CDMA2000 Absolute
LTE / LTE Relative (InterFreq.),
LTE / W-CDMA Relative,
LTE / CDMA2000 Relative,
CDMA2000 / AWGN Relative
LTE / GSM Relative
DC-HSDPA Ior/Ioc
TDS-CDMA Ior/Ioc
DL Output Accuracy:
LA Absolute
CW Interference, CW:
Out of Band
Near Band
For Intermodulation
Characteristics
(0.5 to 3) GHz Modulation
(0.5 to 3) GHz
Modulation, CW
Up to 3 GHz
(3 to 4) GHz
(4 to 6) GHz
(1 to 10) MHz
(10 to 3000) MHz
(3 to 4) GHz
(4 to 13) GHz
(4 to 13) GHz
(400 to 3000) MHz
(3 to 4) GHz
(4 to 4.2) GHz
(4.2 to 6) GHz
0.35 dB
0.33 dB
0.29 dB
0.30 dB
0.27 dB
0.26 dB
0.29 dB
0.41 dB
0.39 dB
0.10 dB
0.10 dB
0.32 dB
0.50 dB
0.59 dB
0.21 dB
0.27 dB
0.43 dB
0.50 dB
1.1 dB
0.27 dB
0.43 dB
0.35 dB
0.42 dB
Signal analyzer,
signal
generator,
power meter &
power sensor | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 8 of 25
Parameter/Equipment
Frequency
CMC2, 4, 11 (±)
Comments
RF Conformance Test System
(ME78xx7)3 (cont)
Modulation Interference:
(680 to 2700) MHz;
(-46 to -15) dBm
UL Relative Power Measurement
Transmit OFF Power Measurement
Accuracy
Relative Carrier Leakage Power
Interference Signal Output
Accuracy
Relative Level Measurement for
LTE
DL Relative Accuracy:
Ior/Ioc (CDMA2000)
Ior/Iot(LTE)
Ior/Ior, Ioc/Ioc (Intra-Band)
Ior/Ioc (TD-SCDMA)
LTE DL/AWGN
Ior/Ior, Ioc/Ioc (Inter-Band)
Ioc/RXLEV, RXLEV/RXLEV
DPCCH Measurement Accuracy
(0.5 to 3) GHz Modulation
LTE, MediaFLO, ATSC
(0.5 to 3) GHz Modulation
(0.5 to 3) GHz
(3 to 4.2) GHz
(4.2 to 6) GHz
(0.5 to 4) GHz
(400 to 3000) MHz
(3 to 4) GHz
(4 to 4.2) GHz
(4.2 to 6) GHz
(0.5 to 6) GHz
(0.5 to 3) GHz
(0.5 to 3) GHz
(0.5 to 3) GHz
(0.5 to 3) GHz
0.26 dB
0.35 dB
0.23 dB
0.31 dB
0.36 dB
0.39 dB
0.40 dB
0.34 dB
0.52 dB
0.60 dB
0.70 dB
0.44 dB
0.10 dB
0.13 dB
0.17 dB
0.39 dB
Signal analyzer,
signal
generator,
power meter &
power sensor | ||
| 9 | 3GPP TS38.521-2; 3GPP TS38.521-3; 3GPP TS38.523-1 | - | 20 to -20 dBm |
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 10 of 25
Parameter/Equipment
Range
CMC2, 16 (±)
Comments
DC Current – Measure
(10 to 100) μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
24 μA/A + 1.1 nA
24 μA/A + 7.9 nA
24 μA/A + 0.082 μA
41 μA/A + 1.1 μA
130 μA/A + 35 μA
Multimeter
Resistance – Generate, Fixed
Points
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
0.33 mΩ
0.43 mΩ
3.6 mΩ
14 mΩ
140 mΩ
1.5 Ω
24 Ω
730 Ω
61 kΩ
Calibrator
Resistance – Measure
(1 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
18 μΩ/Ω + 230 μΩ
14 μΩ/Ω + 2.3 mΩ
12 μΩ/Ω + 2.6 mΩ
12 μΩ/Ω + 25 mΩ
12 μΩ/Ω + 220 mΩ
18 μΩ/Ω + 5.3 Ω
58 μΩ/Ω + 180 Ω
580 μΩ/Ω + 13 kΩ
6.0 mΩ/Ω + 810 kΩ
Multimeter
Parameter/Range
Frequency
CMC2, 16 (±)
Comments
AC Voltage – Generate
(22 to 220) mV
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
110 μV/V + 14 μV
82 μV/V + 14 μV
140 μV/V + 14 μV
320 μV/V + 21 μV
660 μV/V + 23 μV
1.5 mV/V + 28 μV
2.8 mV/V + 47 μV
Calibrator | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 11 of 25
Parameter/Range
Frequency
CMC2, 16 (±)
Comments
AC Voltage – Generate
(cont)
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(220 to 700) V
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
50 Hz to 1 kHz
91 μV/V + 65 μV
43 μV/V + 49 μV
68 μV/V + 49 μV
86 μV/V + 57 μV
340 μV/V + 150 μV
1.1 mV/V + 240 μV
1.8 mV/V + 510 μV
91 μV/V + 430 μV
43 μV/V + 410 μV
68 μV/V + 420 μV
84 μV/V + 450 μV
260 μV/V + 730 μV
1.1 mV/V + 2.1 mV
1.6 mV/V + 3.3 mV
91 μV/V + 4.7 mV
53 μV/V + 4.5 mV
81 μV/V + 4.6 mV
160 μV/V + 5.1 mV
71 μV/V + 5.7 mV
Calibrator
AC Voltage – Measure
(10 to 100) mV
(0.1 to 1) V
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
100 μV/V + 5.9 μV
100 μV/V + 4.3 μV
180 μV/V + 4.3 μV
360 μV/V + 4.3 μV
930 μV/V + 4.3 μV
3.5 mV/V + 13 μV
12 mV/V + 13 μV
81 μV/V + 59 μV
81 μV/V + 43 μV
170 μV/V + 43 μV
350 μV/V + 43 μV
930 μV/V + 43 μV
3.5 mV/V + 130 μV
12 mV/V + 130 μV
Multimeter | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 12 of 25
Parameter/Range
Frequency
CMC2, 16 (±)
Comments
AC Voltage – Measure
(cont)
(1 to 10) V
(10 to 100) V
(100 to 700) V
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
50 Hz to 1 kHz
81 μV/V + 670 μV
81 μV/V + 400 μV
170 μV/V + 530 μV
350 μV/V + 530 μV
930 μV/V + 600 μV
3.5 mV/V + 1.3 mV
12 mV/V + 3.3 mV
240 μV/V + 6.2 mV
240 μV/V + 4.8 mV
240 μV/V + 4.8 mV
410 μV/V + 4.8 mV
1.4 m/V + 4.8 mV
470 μV/V + 50 mV
Multimeter
Frequency Response
Analyzer Linearity at 10 Vp
(-40 to 0) dB
20 Hz to 100 kHz
(100 to 300) kHz
300 kHz to 1 MHz
100 kHz to 15 MHz
0.009 dB
0.037 dB
0.12 dB
0.097 dB
Multimeter
Attenuator
AC Current – Generate
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 1) A
50 Hz to 1 kHz
50 Hz to 1 kHz
50 Hz to 1 kHz
110 μA/A + 0.79 μA
110 μA/A + 8.4 μA
250 μA/A + 97 μA
Calibrator
AC Current – Measure
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(50 to 100) Hz
100 Hz to 1 kHz
(50 to 100) Hz
100 Hz to 1 kHz
(50 to 100) Hz
100 Hz to 1 kHz
700 μA/A + 3.7 μA
350 μA/A + 2.6 μA
700 μA/A + 38 μA
350 μA/A + 26 μA
930 μA/A + 740 μA
1.2 mA/A + 270 μA
Multimeter | ||
| 13 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 13 of 25
Parameter/Range
Frequency
CMC2, 5, 16 (±)
Comments
AC Phase – Measure
(-180 to + 180)°
10 Hz to 100 kHz
100 kHz to 1 MHz
(1 to 5) MHz
0.04°
0.06°
0.22°
Digital oscilloscope
AC Distortion – Measure
400 Hz, 1 kHz
0.12 %
Measuring receiver
III. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 4, 5, 16 (±)
Comments
RF Power – Generate 3
1 mW
0 dBm
(-10 to 0) dBm
(-100 to -10) dBm
(0 to 20) dBm
(-10 to 0) dBm
(-100 to -10) dBm
(0 to 20) dBm
(-10 to 0) dBm
(-100 to -10) dBm
(0 to 20) dBm
(-10 to 0) dBm
(-100 to -10) dBm
(0 to 20) dBm
(-10 to 0) dBm
(-100 to -10) dBm
50 MHz
100 kHz to 5 GHz
(5 to 12) GHz
(12 to 14) GHz
(14 to 18) GHz
(18 to 25) GHz
(25 to 40) GHz
100 kHz to 10 MHz
(0.01 to 3) GHz
(3 to 5) GHz
(5 to 12) GHz
(12 to 18) GHz
0.53 %
0.08 dB
0.09 dB
0.09 dB
0.12 dB
0.14 dB
0.16 dB
0.08 dB
0.10 dB
0.10 dB
0.07 dB
0.09 dB
0.12 dB
0.07 dB
0.08 dB
0.16 dB
0.09 dB
0.10 dB
0.17 dB
0.12 dB
0.13 dB
Reference oscillator
Power meter & power
sensor
Power meter & power
sensor, measuring
receiver, signal
analyzer | -180 to 180 ° |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 14 of 25
Parameter/Range
Frequency
CMC2, 4, 5, 16 (±)
Comments
RF Power – Measuring
Equipment 3
Power Sensor
Correction Factor:
0 dBm
100 kHz
300 kHz
500 kHz
1 MHz
3 MHz
5 MHz
10 MHz
30 MHz
50 MHz
100 MHz
300 MHz
500 MHz
1 GHz
1.5 GHz
2 GHz
2.5 GHz
3 GHz
4 GHz
4.2 GHz
5 GHz
6 GHz
7 GHz
8 GHz
9 GHz
10 GHz
11 GHz
12 GHz
12.4 GHz
13 GHz
14 GHz
15 GHz
16 GHz
17 GHz
18 GHz
19 GHz
20 GHz
21 GHz
22 GHz
23 GHz
24 GHz
25 GHz
1.6 %
1.3 %
1.3 %
1.3 %
1.5 %
1.6 %
1.4 %
1.3 %
1.1 %
1.3 %
1.3 %
1.3 %
1.3 %
1.3 %
1.3 %
1.4 %
1.4 %
1.4 %
1.5 %
1.3 %
1.3 %
1.4 %
1.6 %
1.6 %
1.7 %
1.7 %
1.7 %
1.6 %
1.7 %
1.9 %
1.9 %
1.9 %
2.1 %
2.2 %
1.9 %
2.0 %
2.1 %
2.2 %
2.2 %
2.3 %
2.5 %
Power meter & power
sensor | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 15 of 25
Parameter/Range
Frequency
CMC2, 4, 5, 16 (±)
Comments
RF Power – Measuring
Equipment 3 (cont)–
Power Sensor
Correction Factor:
0 dBm
0 dBm
Power Meter Linearity:
(0 to 10) dBm
(-50 to 0) dBm
26 GHz
26.5 GHz
27 GHz
28 GHz
29 GHz
30 GHz
31 GHz
32 GHz
33 GHz
34 GHz
35 GHz
36 GHz
37 GHz
38 GHz
39 GHz
40 GHz
(0.1 to 1) MHz
1 MHz to 2 GHz
(2 to 6) GHz
(6 to 8) GHz
(8 to 12) GHz
(12 to 18) GHz
10 MHz to 6 GHz
(6 to 12) GHz
(12 to 18) GHz
10 MHz to 6 GHz
(6 to 12) GHz
(12 to 18) GHz
2.6 %
2.9 %
3.3 %
3.0 %
2.8 %
2.6 %
2.7 %
2.6 %
2.6 %
2.7 %
2.6 %
2.5 %
2.7 %
2.6 %
2.8 %
2.7 %
1.7 %
1.6 %
1.5 %
1.5 %
1.7 %
2.3 %
3.9 %
6.4 %
7.1 %
4.7 %
6.7 %
7.0 %
Power meter & power
sensor
Power meter & power
sensor, step attenuator | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 16 of 25
Parameter/Range
Frequency
CMC2, 4, 5, 16 (±)
Comments
Frequency Modulation –
Generate
Deviation: (0.3 to 4) kHz
Deviation: (4 to 40) kHz
Deviation: (0.3 to 4) kHz
Deviation: (4 to 40) kHz
Deviation: (40 to 400) kHz
Deviation: (0.3 to 4) kHz
Deviation: (4 to 40) kHz
Deviation: (40 to 400) kHz
(0.25 to 10) MHz
Rate: 20 Hz to 10 kHz
(10 to 1300) MHz
Rate: 20 Hz to 200 kHz
(10 to 1300) MHz
Rate: 50 Hz to 100 kHz
6.9 % + 1 Hz
3.9 % + 10 Hz
8.7 % + 1 Hz
6.6 % + 10 Hz
5.9 % + 100 Hz
6.5 % + 1 Hz
3.1 % + 10 Hz
1.4 % + 100 Hz
Measuring receiver
Frequency Modulation –
Measuring Equipment
Deviation: (0.3 to 4) kHz
Deviation: (4 to 40) kHz
Deviation: (0.3 to 4) kHz
Deviation: (4 to 40) kHz
Deviation: (40 to 400) kHz
Deviation: (0.3 to 4) kHz
Deviation: (4 to 40) kHz
Deviation: (40 to 400) kHz
(0.25 to 10) MHz
Rate: 20 Hz to 10 kHz
(10 to 1300) MHz
Rate: 20 Hz to 200 kHz
(10 to 1300) MHz
Rate: 50 Hz to 100 kHz
7.0 % + 1 Hz
4.0 % + 10 Hz
8.9 % + 1 Hz
6.6 % + 10 Hz
5.9 % + 100 Hz
6.6 % + 1 Hz
3.2 % + 10 Hz
1.4 % + 100 Hz
Measuring receiver
Attenuation – Measure
(0 to 90) dB
(90 to 100) dB
10 MHz to 18 GHz
0.25 dB + M
0.35 dB + M
Measuring receiver
Attenuation – Measuring
Equipment
(0 to 80) dB
90 dB
100 dB
(0 to 80) dB
90 dB
100 dB
10 MHz to 12 GHz
(12 to 18) GHz
0.22 dB
0.32 dB
0.60 dB
0.38 dB
0.48 dB
1.1 dB
Step attenuator | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 17 of 25
Parameter/Range
Frequency
CMC2, 4, 5, 16 (±)
Comments
Amplitude Modulation –
Generate
Depth: (5 to 40) %
Depth: (40 to 90) %
Depth: (5 to 40) %
Depth: (40 to 90) %
Depth: (5 to 40) %
Depth: (40 to 90) %
Depth: (5 to 40) %
Depth: (40 to 90) %
(0.15 to 10) MHz
Rate: 20 Hz to 10 kHz
(0.15 to 10) MHz
Rate: 50 Hz to 10 kHz
(10 to 1300) MHz
Rate: 20 Hz to 100 kHz
(10 to 1300) MHz
Rate: 50 Hz to 50 kHz
4.3 % + 0.01 % (AM)
3.6 % + 0.1 % (AM)
3.3 % + 0.01 % (AM)
2.5 % + 0.1 % (AM)
7.1 % + 0.01 % (AM)
3.7 % + 0.1 % (AM)
5.2 % + 0.01 % (AM)
1.5 % + 0.1 % (AM)
Measuring receiver
Amplitude Modulation –
Measuring Equipment
Depth: (5 to 40) %
Depth: (40 to 90) %
Depth: (5 to 40) %
Depth: (40 to 90) %
Depth: (5 to 40) %
Depth: (40 to 90) %
Depth: (5 to 40) %
Depth: (40 to 90) %
(0.15 to 10) MHz
Rate: 20 Hz to 10 kHz
(0.15 to 10) MHz
Rate: 50 Hz to 10 kHz
(10 to 1300) MHz
Rate: 20 Hz to 100 kHz
(10 to 1300) MHz
Rate: 50 Hz to 50 kHz
4.3 % + 0.01 % (AM)
3.6 % + 0.1 % (AM)
3.4 % + 0.01 % (AM)
2.5 % + 0.1 % (AM)
7.1 % + 0.01 % (AM)
3.7 % + 0.1 % (AM)
5.3 % + 0.01 % (AM)
1.4 % + 0.1 % (AM)
Measuring receiver
Spectrum Analyzer8 –
Standard Frequency
Accuracy
Displayed Frequency
Accuracy
Span Accuracy
10 MHz
10 Hz to 1 GHz
(1 to 40) GHz
10 kHz to 40 GHz
2.4 μHz
1.3 Hz
1.3 Hz
0.013 %
Cesium standard &
precision phase
comparator
Cesium standard &
signal generator
Cesium standard &
signal generator | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 18 of 25
Parameter/Equipment
Frequency
CMC2, 4 (±)
Comments
Spectrum Analyzer8 – (cont)
Frequency Response,
Reference Level Accuracy,
Absolute Amplitude Accuracy
100 kHz
300 kHz
500 kHz
1 MHz
3 MHz
5 MHz
10 MHz
30 MHz
50 MHz
100 MHz
300 MHz
500 MHz
1 GHz
1.5 GHz
2 GHz
2.5 GHz
3 GHz
4 GHz
4.2 GHz
5 GHz
6 GHz
7 GHz
8 GHz
9 GHz
10 GHz
11 GHz
12 GHz
12.4 GHz
13 GHz
14 GHz
15 GHz
16 GHz
17 GHz
18 GHz
19 GHz
20 GHz
21 GHz
22 GHz
23 GHz
24 GHz
25 GHz
26 GHz
26.5 GHz
27 GHz
28 GHz
29 GHz
30 GHz
0.10 dB
0.09 dB
0.10 dB
0.10 dB
0.10 dB
0.10 dB
0.10 dB
0.09 dB
0.09 dB
0.09 dB
0.10 dB
0.10 dB
0.10 dB
0.10 dB
0.10 dB
0.11 dB
0.11 dB
0.11 dB
0.11 dB
0.11 dB
0.11 dB
0.11 dB
0.12 dB
0.12 dB
0.11 dB
0.11 dB
0.11 dB
0.14 dB
0.12 dB
0.12 dB
0.12 dB
0.12 dB
0.13 dB
0.13 dB
0.12 dB
0.13 dB
0.14 dB
0.14 dB
0.14 dB
0.15 dB
0.16 dB
0.17 dB
0.17 dB
0.17 dB
0.17 dB
0.18 dB
0.18 dB
Power meter & power
sensor | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 19 of 25
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Spectrum Analyzer8 – (cont)
Frequency Response,
Reference Level Accuracy,
Absolute Amplitude Accuracy
Reference Level Accuracy,
Absolute Amplitude Accuracy:
(-100 to -10) dBm
Scale Fidelity:
(0 to 90) dB
(90 to 100) dB
(0 to 90) dB
(90 to 100) dB
(0 to 80) dB
(80 to 90) dB
(90 to 100) dB
(0 to 80) dB
(80 to 90) dB
(90 to 100) dB
Attenuator Switching Accuracy
Bandwidth Switching Accuracy
Bandwidth Accuracy
31 GHz
32 GHz
33 GHz
34 GHz
35 GHz
36 GHz
37 GHz
38 GHz
39 GHz
40 GHz
(0.1 to 1) MHz
1 MHz to 2 GHz
(2 to 6) GHz
(6 to 8) GHz
(8 to 12) GHz
(12 to 18) GHz
(0.01 to 2) GHz
(2 to 10) GHz
(10 to 12) GHz
(12 to 18) GHz
(0.01 to 2) GHz
(2 to 10) GHz
(10 to 12) GHz
(12 to 18) GHz
10 kHz to 40 GHz
10 kHz to 40 GHz
10 Hz to 50 MHz
0.20 dB
0.18 dB
0.16 dB
0.15 dB
0.15 dB
0.14 dB
0.16 dB
0.15 dB
0.16 dB
0.17 dB
0.12 dB
0.12 dB
0.12 dB
0.13 dB
0.15 dB
0.17 dB
0.26 dB
0.26 dB
0.34 dB
0.39 dB
0.22 dB
0.38 dB
0.26 dB
0.47 dB
0.22 dB
0.32 dB
0.60 dB
0.38 dB
0.48 dB
1.1 dB
0.09 dB
0.09 dB
3.5 %
Signal generator
Power meter & power
sensor, step attenuator
Step attenuator | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 20 of 25
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Signal Generator –
Standard Frequency Accuracy
Frequency Accuracy
Linearity:
(-50 to 20) dBm
(-100 to -50) dBm
Absolute Level Accuracy:
0 dBm
(-10 to 0) dBm
(-100 to -10) dBm
(0 to 20) dBm
(-10 to 0) dBm
(-100 to -10) dBm
(0 to 20) dBm
(-10 to 0) dBm
(-100 to -10) dBm
10 MHz
10 Hz to 1 MHz
(1 to 10) MHz
10 MHz
10 MHz to 1 GHz
(1 to 10) GHz
(10 to 20) GHz
(20 to 30) GHz
(30 to 40) GHz
(0.01 to 18) GHz
100 kHz to 5 GHz
(5 to 12) GHz
(12 to 14) GHz
(14 to 18) GHz
(18 to 25) GHz
(25 to 40) GHz
100 kHz to 10 MHz
(0.01 to 3) GHz
(3 to 5) GHz
2.4 μHz
0.012 Hz
0.85 mHz
0.85 mHz
0.075 Hz
0.14 Hz
0.26 Hz
0.37 Hz
0.49 Hz
0.31 dB
0.39 dB
0.08 dB
0.09 dB
0.09 dB
0.12 dB
0.14 dB
0.16 dB
0.08 dB
0.10 dB
0.10 dB
0.07 dB
0.09 dB
0.12 dB
0.07 dB
0.08 dB
Cesium standard &
precision phase
comparator
Cesium standard &
frequency counter
Spectrum anlyzer &
step attenuator
Power meter & power
sensor
Power meter & power
sensor, measuring
receiver | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 21 of 25
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Signal Generator – (cont)
Absolute Level Accuracy:
(0 to 20) dBm
(-10 to 0) dBm
(-100 to -10) dBm
(0 to 20) dBm
(-10 to 0) dBm
(-100 to -10) dBm
2nd & 3rd Harmonic:
(0 to -70) dBc
(0 to -90) dBc
(0 to -90) dBc
FM Modulation Accuracy:
Deviation: (0.3 to 4) kHz
Deviation: (4 to 40) kHz
Deviation: (0.3 to 4) kHz
Deviation: (4 to 40) kHz
Deviation: (40 to 400) kHz
Deviation: (0.3 to 4) kHz
Deviation: (4 to 40) kHz
Deviation: (40 to 400) kHz
AM Modulation Accuracy
Depth: (5 to 40) %
Depth: (40 to 90) %
Depth: (5 to 40) %
Depth: (40 to 90) %
Depth: (5 to 40) %
Depth: (40 to 90) %
Depth: (5 to 40) %
Depth: (40 to 90) %
(5 to 12) GHz
(12 to 18) GHz
(0.02 to 3) GHz
(3 to 13.5) GHz
(13.5 to 18) GHz
(0.25 to 10) MHz
Mod. Frequency: 20 Hz
to 10 kHz
(10 to 1300) MHz
Mod. Frequency: 20 Hz
to 200 kHz
(10 to 1300) MHz
Mod. Frequency: 50 Hz
to 100 kHz
(0.15 to 10) MHz
Rate: 20 Hz to 10 kHz
(0.15 to 10) MHz
Rate: 50 Hz to 10 kHz
(10 to 1300) MHz
Rate: 20 Hz to 100 kHz
(10 to 1300) MHz
Rate: 50 Hz to 50 kHz
0.16 dB
0.09 dB
0.10 dB
0.17 dB
0.12 dB
0.13 dB
0.9 dB
1.7 dB
2.9 dB
6.9 % + 1 Hz
3.9 % + 10 Hz
8.7 % + 1 Hz
6.6 % + 10 Hz
5.9 % + 100 Hz
6.5 % + 1 Hz
3.1 % + 10 Hz
1.4 % + 100 Hz
4.3 % + 0.01 % (AM)
3.6 % + 0.1 % (AM)
3.3 % + 0.01 % (AM)
2.5 % + 0.1 % (AM)
7.1 % + 0.01 % (AM)
3.7 % + 0.1 % (AM)
5.2 % + 0.01 % (AM)
1.5 % + 0.1 % (AM)
Power meter &
power sensor,
measuring
receiver
Signal analyzer
Measuring
receiver | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 22 of 25
Parameter/Range
Frequency
CMC2, 16 (±)
Comments
Parameters for S11, S12, S21, S22
–
Reflection S11/S22 Magnitude
& Phase – Measure9:
(0.0001 to 0.5) lin
(0.5 to 1) lin
(0.0001 to 0.03) lin
(0.03 to 0.1) lin
(0.1 to 0.2) lin
(0.2 to 1) lin
(0.0001 to 0.5) lin
(0.5 to 1) lin
(0.0001 to 0.03) lin
(0.03 to 0.1) lin
(0.1 to 0.2) lin
(0.2 to 1) lin
(0.0001 to 0.5) lin
(0.5 to 1) lin
(0.0001 to 0.03) lin
(0.03 to 0.1) lin
(0.1 to 0.2) lin
(0.2 to 1) lin
(70 to 300) kHz
300 kHz to 18 GHz
(18 to 40) GHz
(0.007 to 0.011) lin
(0.011 to 0.021) lin
(90 to 13) °
(13 to 4.2) °
(4.2 to 2.3) °
(2.3 to 0.82) °
(0.010 to 0.019) lin
(0.019 to 0.034) lin
(90 to 21) °
(21 to 7.4) °
(7.4 to 4.5) °
(4.5 to 2.0) °
(0.014 to 0.032) lin
(0.032 to 0.059) lin
(90 to 26) °
(26 to 11) °
(11 to 7.0) °
(7.0 to 5.0) °
One-port device
Insertable devices only
Vector network
analyzer calibration kit | ||
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 23 of 25
Parameter/Range
Frequency
CMC2, 16 (±)
Comments
Transmission S12/S21,
Magnitude & Phase-
Measure9
(0 to -5) dB
(-5 to -30) dB
(-30 to -35) dB
(-35 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(0 to -5) dB
(-5 to -30) dB
(-30 to -35) dB
(-35 to -80) dB
(0 to -5) dB
(-5 to -30) dB
(-30 to -35) dB
(-35 to -80) dB
(70 to 300) kHz
300 kHz to 18 GHz
(18 to 40) GHz
(0.062 to 0.039) dB
(0.40 to 0.30) °
0.039 dB
0.30 °
(0.039 to 0.044) dB
(0.30 to 0.40) °
0.044 dB
0.40 °
(0.044 to 0.048) dB
(0.40 to 0.45) °
(0.048 to 0.080) dB
(0.45 to 0.50) °
(0.18 to 0.16) dB
(1.8 to 1.6) °
0.16 dB
1.6 °
(0.16 to 0.17) dB
(1.6 to 1.7) °
0.17 dB
1.7 °
(0.33 to 0.31) dB
(3.4 to 3.3) °
0.31 dB
3.3 °
(0.31 to 0.32) dB
(3.3 to 3.4) °
0.32 dB
3.4 °
Non-reflective device
Insertable devices only
Vector network analyzer
calibration kit | ||
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3128.01) 7/15/2025 Page 24 of 25
IV. Time & Frequency
Parameter/Equipment
Range
CMC2, 11 (±)
Comments
Frequency – Measure
High Stability Frequency
Standard
Frequency Generators
10 MHz
10 Hz to 1 MHz
(1 to 10) MHz
10 MHz
10 MHz to 1 GHz
(1 to 10) GHz
(10 to 20) GHz
(20 to 30) GHz
(30 to 40) GHz
2.4 μHz
0.012 Hz
0.85 mHz
0.85 mHz
0.075 Hz
0.14 Hz
0.26 Hz
0.37 Hz
0.49 Hz
Cesium standard &
precision phase
comparator
Cesium standard &
frequency counter
Frequency – Measuring
Equipment
Counters & Timers
10 Hz to 1 MHz
(1 to 10) MHz
10 MHz to 1 GHz
(1 to 10) GHz
(10 to 20) GHz
(20 to 30) GHz
(30 to 40) GHz
10 MHz
0.058 Hz
0.058 Hz
0.17 Hz
0.22 Hz
0.37 Hz
0.49 Hz
0.63 Hz
0.067 mHz
Cesium standard & signal
generator
Cesium standard
______________________________________________________________________
1 This laboratory offers commercial calibration and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The usual allowance for the uncertainty
introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC. | ||
| 25 | 3GPP TS34.121-2; 3GPP TS34.521-3; 36521-3 | - | - |
| 26 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.