VIRLAB
Polígono Industrial Asteasu, zona B, nº 44, 20159, Asteasu, Spain
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
No contact information available
Open ENAC register entryWork at VIRLAB?
Claim this profile to keep it accurate.
Register record
- ENACRefreshed
- 54/LE131Active
Accredited standards
9Our reading of the ENAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 980Name not checked yet
UNE-EN 60068-2-64; EN 60068-2-64; IEC 680068-2-64; UNE-EN IEC 60068-3-3; EN IEC 60068-3-3; IEC 60068-3-3; UNE-EN 60068-3-3:1994; EN 60068-3-3:1993; IEC 60008-3-3:1991; IEC/IEEE 60980-344; IEEE-344:2013; IEEE-344:2004; IEEE-344:1987; IEC 60980:1989; CEI IEC 980:1989
IEC 60008-3-3Name not checked yet
UNE-EN 60068-2-64; EN 60068-2-64; IEC 680068-2-64; UNE-EN IEC 60068-3-3; EN IEC 60068-3-3; IEC 60068-3-3; UNE-EN 60068-3-3:1994; EN 60068-3-3:1993; IEC 60008-3-3:1991; IEC/IEEE 60980-344; IEEE-344:2013; IEEE-344:2004; IEEE-344:1987; IEC 60980:1989; CEI IEC 980:1989
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)Certificate says EN 60068-2-6. Probably the same standard; not checked against the EN document.
UNE-EN 60068-2-6; EN 60068-2-6; IEC 60068-2-6
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: ShockCertificate says EN 60068-2-27. Probably the same standard; not checked against the EN document.
UNE-EN 60068-2-27; EN 60068-2-27; IEC 60068-2-27; UNE-EN 60068-2-57; EN 60068-2-57; IEC 60068-2-57
IEC 60068-2-57Name not checked yet
UNE-EN 60068-2-27; EN 60068-2-27; IEC 60068-2-27; UNE-EN 60068-2-57; EN 60068-2-57; IEC 60068-2-57
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidanceCertificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.
UNE-EN 60068-2-64; EN 60068-2-64; IEC 680068-2-64; UNE-EN IEC 60068-3-3; EN IEC 60068-3-3; IEC 60068-3-3; UNE-EN 60068-3-3:1994; EN 60068-3-3:1993; IEC 60008-3-3:1991; IEC/IEEE 60980-344; IEEE-344:2013; IEEE-344:2004; IEEE-344:1987; IEC 60980:1989; CEI IEC 980:1989
IEC 60068-3-3Name not checked yet
UNE-EN 60068-2-64; EN 60068-2-64; IEC 680068-2-64; UNE-EN IEC 60068-3-3; EN IEC 60068-3-3; IEC 60068-3-3; UNE-EN 60068-3-3:1994; EN 60068-3-3:1993; IEC 60008-3-3:1991; IEC/IEEE 60980-344; IEEE-344:2013; IEEE-344:2004; IEEE-344:1987; IEC 60980:1989; CEI IEC 980:1989
IEC 60980Name not checked yet
UNE-EN 60068-2-64; EN 60068-2-64; IEC 680068-2-64; UNE-EN IEC 60068-3-3; EN IEC 60068-3-3; IEC 60068-3-3; UNE-EN 60068-3-3:1994; EN 60068-3-3:1993; IEC 60008-3-3:1991; IEC/IEEE 60980-344; IEEE-344:2013; IEEE-344:2004; IEEE-344:1987; IEC 60980:1989; CEI IEC 980:1989
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
UNE-EN 61373; EN 61373; IEC 61373; UNE-EN 61373:1999; EN 61373:1999; IEC 61373:1999
Scope as published by ENAC
4 lines
ISO/IEC 17025
Active54/LE131
Accredited scope, certificate 54/LE131
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | materials | UNE-EN 60068-2-6; EN 60068-2-6; IEC 60068-2-6 | Equipment, components and other items | See scope document |
| 2 | materials | UNE-EN 60068-2-27; EN 60068-2-27; IEC 60068-2-27; UNE-EN 60068-2-57; EN 60068-2-57; IEC 60068-2-57 | - | - |
| 3 | environmental | UNE-EN 60068-2-64; EN 60068-2-64; IEC 680068-2-64; UNE-EN IEC 60068-3-3; EN IEC 60068-3-3; IEC 60068-3-3; UNE-EN 60068-3-3:1994; EN 60068-3-3:1993; IEC 60008-3-3:1991; IEC/IEEE 60980-344; IEEE-344:2013; IEEE-344:2004; IEEE-344:1987; IEC 60980:1989; CEI IEC 980:1989 | - | See scope document |
| 4 | mechanical | UNE-EN 61373; EN 61373; IEC 61373; UNE-EN 61373:1999; EN 61373:1999; IEC 61373:1999 | rolling stock (railway vehicles) | 1 to 2500 Hz |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the ENAC register on .