Shenzhen VOP Testing Technology Co.,
103, Building 5, Wanyan Industrial Park, Qiaotou Community, Fuhai Street, Baoan District, Shenzhen, Guangdong, People's Republic of China, Shenzhen, Guangdong, China
- Accredited standards
- 54
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 54 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60335 series13
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements+1 national
National versions in the same scope
AS/NZS 60335.1national version with changes
IEC 60335-2-2Household and similar electrical appliances - Safety - Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances+1 national
National versions in the same scope
AS/NZS 60335.2.2national version with changes
IEC 60335-2-8Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers, hair clippers and similar appliances+1 national
National versions in the same scope
AS/NZS 60335.2.8identical to it
IEC 60335-2-9Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances+1 national
National versions in the same scope
AS/NZS 60335.2.9probably the same standard; matched by number only
IEC 60335-2-14+1 national
National versions in the same scope
AS/NZS 60335.2.14national version with changes
IEC 60335-2-15+1 national
National versions in the same scope
AS/NZS 60335.2.15national version with changes
IEC 60335-2-23+1 national
National versions in the same scope
AS/NZS 60335.2.23national version with changes
IEC 60335-2-29+1 national
National versions in the same scope
AS/NZS 60335.2.29national version with changes
IEC 60335-2-32+1 national
National versions in the same scope
AS/NZS 60335.2.32identical to it
IEC 60335-2-45+1 national
National versions in the same scope
AS/NZS 60335.2.45probably the same standard; matched by number only
IEC 60335-2-65+1 national
National versions in the same scope
AS/NZS 60335.2.65identical to it
IEC 60335-2-80+1 national
National versions in the same scope
AS/NZS 60335.2.80national version with changes
IEC 60335-2-98+1 national
National versions in the same scope
AS/NZS 60335.2.98national version with changes
IEC9
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62493
IEC 62560+1 national
National versions in the same scope
AS/NZS 62560national version with changes
IEC 62680-1-2
IEC 62680-1-3
IEC 62841-1
EN7
EN 15194
EN 17128
EN 50364
EN 50383
EN 50385
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
IEC 60598 series7
IEC 60598-1Luminaires - Part 1: General requirements and tests+1 national
National versions in the same scope
AS/NZS 60598.1national version with changes
IEC 60598-2-1+1 national
National versions in the same scope
AS/NZS 60598.2.1probably the same standard; matched by number only
IEC 60598-2-2+1 national
National versions in the same scope
AS/NZS 60598.2.2national version with changes
IEC 60598-2-4+1 national
National versions in the same scope
AS/NZS 60598.2.4probably the same standard; matched by number only
IEC 60598-2-5+1 national
National versions in the same scope
AS/NZS 60598.2.5probably the same standard; matched by number only
IEC 60598-2-17+1 national
National versions in the same scope
AS/NZS 60598.2.17probably the same standard; matched by number only
IEC 60598-2-20+1 national
National versions in the same scope
AS/NZS 60598.2.20national version with changes
CISPR5
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
AS/NZS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national
National versions in the same scope
AS/NZS CISPR 14-1national version with changes
AS/NZS CISPR 14.1national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national
National versions in the same scope
AS CISPR 15national version with changes
AS/NZS CISPR 15national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national
National versions in the same scope
AS/NZS CISPR 32identical to it
VCCI-CISPR 32probably the same standard; matched by number only
IEC 61000 series5
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
AS/NZS 61000.4.2probably the same standard; matched by number only
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
AS/NZS 61000.4.3probably the same standard; matched by number only
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
AS/NZS 61000.4.4probably the same standard; matched by number only
EN 18031 series3
EN 18031-1
EN 18031-2
EN 18031-3
IEC 61347 series3
IEC 61347-1+1 national
National versions in the same scope
AS/NZS 61347.1national version with changes
IEC 61347-2-12+1 national
National versions in the same scope
AS/NZS 61347.2.12probably the same standard; matched by number only
IEC 61347-2-13+1 national
National versions in the same scope
AS/NZS 61347.2.13probably the same standard; matched by number only
Other standards2
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
EN 62311; EN IEC 62311; BS EN IEC 62311; EN 62479; IEC 62479; BS EN 62479; EN 50385; BS EN 50385; EN 50383; BS EN 50383; EN 50364; BS EN 50364; IEC 62493; EN 62493; BS EN 62493; IEC 62233; EN 62233; BS EN 62233; EN 50663; BS EN 50663; EN 50665; BS EN 50665; SPR-002; AS/NZS 2772.2; IEC 62368-1; EN IEC 62368-1; AS/NZS 62368.1; UL 62368-1; CAN/CSA-C22.2 No. 62368-1; BS EN IEC 62368-1; UL 1310; UL 2089; ANSI/UL 2089; IEC 62680-1-2; EN IEC 62680-1-2; BS EN IEC 62680-1-2; IEC 62680-1-3; EN IEC 62680-1-3; BS EN IEC 62680-1-3; IEC 60335-1; EN 60335-1; BS EN 60335-1; AS/NZS 60335.1; UL 60335-1; CAN/CSA-C22.2 No. 60335-1; IEC 60335-2-2; EN 60335-2-2; BS EN 60335-2-2; AS/NZS 60335.2.2; IEC 60335-2-8; EN 60335-2-8; BS EN 60335-2-8; AS/NZS 60335.2.8; UL 60335-2-8; CAN/CSA-C22.2 No. 60335-2-8; IEC 60335-2-9; EN 60335-2-9; BS EN 60335-2-9; AS/NZS 60335.2.9; IEC 60335-2-14; EN 60335-2-14; BS EN 60335-2-14; AS/NZS 60335.2.14; IEC 60335-2-15; EN 60335-2-15; BS EN 60335-2-15; AS/NZS 60335.2.15; IEC 60335-2-23; EN 60335-2-23; BS EN 60335-2-23; AS/NZS 60335.2.23; IEC 60335-2-29; EN 60335-2-29; BS EN 60335-2-29; AS/NZS 60335.2.29; IEC 60335-2-32; EN 60335-2-32; BS EN 60335-2-32; AS/NZS 60335.2.32
IEC 60335-2-45; EN 60335-2-45; BS EN 60335-2-45; AS/NZS 60335.2.45; IEC 60335-2-65; EN 60335-2-65; BS EN 60335-2-65; AS/NZS 60335.2.65; IEC 60335-2-80; EN 60335-2-80; BS EN 60335-2-80; AS/NZS 60335.2.80; UL 507; IEC 60335-2-98; EN 60335-2-98; BS EN 60335-2-98; AS/NZS 60335.2.98; UL 998; CSA C22.2 No. 104; UL 1017; CSA C22.2 No. 243; UL 1082; UL 499; UL 859; UL 1026; UL 1278; UL 1995; IEC 60598-1; EN IEC 60598-1; BS EN IEC 60598-1; AS/NZS 60598.1; UL 1598; CSA C22.2 No. 250.0; IEC 60598-2-1; EN IEC 60598-2-1; BS EN IEC 60598-2-1; AS/NZS 60598.2.1; IEC 60598-2-2; EN 60598-2-2; BS EN 60598-2-2; AS/NZS 60598.2.2; IEC 60598-2-4; EN 60598-2-4; BS EN 60598-2-4; AS/NZS 60598.2.4; UL 153; IEC 60598-2-5; EN 60598-2-5; BS EN 60598-2-5; AS/NZS 60598.2.5; IEC 60598-2-17; EN IEC 60598-2-17; BS EN IEC 60598-2-17; AS/NZS 60598.2.17; UL 1573; IEC 60598-2-20; EN 60598-2-20; BS EN 60598-2-20; AS/NZS 60598.2.20; IEC 62560; EN 62560; BS EN 62560; AS/NZS 62560
UL 1576; CSA C22.2 No. 250.5; UL 1993; CSA C22.2 No. 1993; UL 588; ANSI/UL 588; IEC 61347-1; EN 61347-1; BS EN 61347-1; AS/NZS 61347.1; IEC 61347-2-12; EN 61347-2-12; BS EN 61347-2-12; AS/NZS 61347.2.12; IEC 61347-2-13; EN 61347-2-13; BS EN 61347-2-13; AS/NZS 61347.2.13; IEC 62841-1; EN 62841-1; BS EN 62841-1; UL 62841-1; CAN/CSA-C22.2 No. 62841-1; EN 15194; BS EN 15194; UL 2849; ANSI/UL 2849-2022; EN 17128; BS EN 17128; UL 2272; ANSI/CAN/UL 2272; EN 18031-1; BS EN 18031-1; EN 18031-2; BS EN 18031-2; EN 18031-3; BS EN 18031-3
CFR 47, FCC Part 15B; ANSI C63.4:2014; CRF 47, FCC Part 18; FCC OST/MP5:1986; ICES-GEN; ICES-001; ICES-003; ICES-005; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; EN 55032; BS EN 55032; AS/NZS CISPR 32; CISPR 11; EN 55011; BS EN 55011; AS/NZS CISPR 11; AS CISPR 11; AS CISPR 15; J55014-1; J55032; CISPR 14-1; EN 55014-1; BS EN 55014-1; EN IEC 55014-1; BS EN IEC 55014-1; AS/NZS CISPR 14-1; AS/NZS CISPR 14.1; CISPR 15; EN 55015; BS EN 55015; EN IEC 55015; BS EN IEC 55015; AS/NZS CISPR 15; VCCI V-3; VCCI V-4; VCCI-CISPR 32; IEC 61000-3-2; EN 61000-3-2; BS EN 61000-3-2; EN IEC 61000-3-2; AS/NZS 61000.3.2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; AS/NZS 61000.3.3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; AS/NZS 61000.4.2; IEC 61000-4-3; EN 61000-4-3; BS EN 61000-4-3; AS/NZS 61000.4.3; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; AS/NZS 61000.4.4
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; ANSI C63.17:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
8 lines
ISO/IEC 17025
Active7579.01
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 7579.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CFR 47, FCC Part 15B; ANSI C63.4:2014; CRF 47, FCC Part 18; FCC OST/MP5:1986; ICES-GEN; ICES-001; ICES-003; ICES-005; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; EN 55032; BS EN 55032; AS/NZS CISPR 32; CISPR 11; EN 55011; BS EN 55011; AS/NZS CISPR 11; AS CISPR 11; AS CISPR 15; J55014-1; J55032; CISPR 14-1; EN 55014-1; BS EN 55014-1; EN IEC 55014-1; BS EN IEC 55014-1; AS/NZS CISPR 14-1; AS/NZS CISPR 14.1; CISPR 15; EN 55015; BS EN 55015; EN IEC 55015; BS EN IEC 55015; AS/NZS CISPR 15; VCCI V-3; VCCI V-4; VCCI-CISPR 32; IEC 61000-3-2; EN 61000-3-2; BS EN 61000-3-2; EN IEC 61000-3-2; AS/NZS 61000.3.2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; AS/NZS 61000.3.3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; AS/NZS 61000.4.2; IEC 61000-4-3; EN 61000-4-3; BS EN 61000-4-3; AS/NZS 61000.4.3; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; AS/NZS 61000.4.4 | - | to 6 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7579.01) Revised 01/16/2026 Page 2 of 7
Test(s): Test Method(s)1:
Surge Immunity IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5;
AS/NZS 61000.4.5
Conducted Immunity IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6;
AS/NZS 61000.4.6
Magnetic Fields Immunity IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8;
AS/NZS 61000.4-8
Voltage Dip & Interrupt IEC 61000-4-11; EN 61000-4-11; BS EN 61000-4-11;
AS/NZS 61000.4.11
Generic and Product Specific
Standards
IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1;
BS EN IEC 61000-6-1; IEC 61000-6-2; EN 61000-6-2;
EN IEC 61000-6-2; BS EN IEC 61000-6-2;
IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3;
BS EN IEC 61000-6-3; IEC 61000-6-4; EN 61000-6-4;
AS/NZS 61000.6.1; AS/NZS 61000.6.2; AS/NZS 61000.6.3;
AS/NZS 61000.6.4; IEC 60601-1-2; EN 60601-1-2;
BS EN 60601-1-2; EN 55024; CISPR 24; AS/NZS CISPR 24;
EN 55035; BS EN 55035; CISPR 35; AS/NZS CISPR 35;
CISPR 14-2; IEC 61326-1; EN 61326-1; EN IEC 61326-1;
BS EN IEC 61326-1; IEC 61326-2-6; EN 61326-2-6;
EN IEC 61326-2-6; BS EN IEC 61326-2-6;
EN 50130-4; IEC/EN 62040-2; EN IEC 62040-2;
BS EN IEC 62040-2; EN 50121-4; EN 50121-3-2;
EN 62493; EN 300 386; EN 55014-2; EN IEC 55014-2;
BS EN IEC 55014-2; EN 61547; EN IEC 61547; BS EN 61547;
ETSI EN 301 489-1; ETSI EN 301 489-2;
ETSI EN 301 489-3; ETSI EN 301 489-5; ETSI EN 301 489-6;
ETSI EN 301 489-9; ETSI EN 301 489-13;
ETSI EN 301 489-15; ETSI EN 301 489-17;
ETSI EN 301 489-19; ETSI EN 301 489-33;
ETSI EN 301 489-34;
ETSI EN 301 489-50; ETSI EN 301 489-52; ETSI EN 301 489-53
Japan Ordinance of MPT No.37, Article 2 Paragraph 1 Item 19;
Article 2 Paragraph 1 of Item 19-2;
Article 2 Paragraph 1 of Item 19-3;
Article 2 Paragraph 1 of Item 19-3-2;
Article 2 Paragraph 1 of Item 11‐3;
Article 2 Paragraph 1 of Item 11‐4;
Article 2 Paragraph 1 of Item 11‐7;
Article 2 Paragraph 1 of Item 11‐8;
Article 2 Paragraph 1 of Item 11‐19;
Article 2 Paragraph 1 of Item 11‐19-2;
Article 2 Paragraph 1 of Item 11‐19-3;
Article 2 Paragraph 1 of Item 11‐21;
Article 2 Paragraph 1 of Item 54 | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7579.01) Revised 01/16/2026 Page 3 of 7
Test(s): Test Method(s)1:
Radio
(excluding SAR cont.)
Unlicensed Radio - FCC
CFR 47, FCC Parts 15C, 15E, and 15F
(using ANSI C63.10:2020)
CFR 47 FCC Part 15E
(using FCC KDB 905462 D02 (v02), April 8, 2016);
CFR FCC Part 15D (using ANSI C63.17:2013);
CFR 47, FCC 22, 24, 25, 27, 30,73,74,90, 95, 96, 97, and 101
(using ANSI C63.26:2015, ANSI/TIA-603-E:2016, and
TIA-102.CAAA-E)
Radio (excluding SAR)
Radio –ISED
RSS-GEN; RSS-119; RSS-123; RSS-130; RSS-131;
RSS-132; RSS-133; RSS-134; RSS-139; RSS-140;
RSS-194; RSS-195; RSS-198; RSS-199;
RSS-210 (< 40 GHz); RSS-216 (< 40 GHz);
RSS-220 (< 40 GHz); RSS-247; RSS-310
European Union (EU)
ETSI EN 300 086; ETSI EN 300 113;
ETSI EN 300 220-1; ETSI EN 300 220-2;
ETSI EN 300 220-3-1;
ETSI EN 300 220-3-2; ETSI EN 300 220-4;
ETSI EN 300 330; ETSI EN 300 440;
ETSI EN 303 345-1;
ETSI EN 301 406-1; ETSI EN 301 406-2;
ETSI EN 302 065-1; ETSI EN 302 065-2;
ETSI EN 302 065-3; ETSI EN 302 065-4;
ETSI EN 302 065-5;
ETSI EN 303 413;
ETSI EN 303 417; ETSI EN 300 422-1;
ETSI EN 300 422-2; ETSI EN 300 422-3;
ETSI EN 300 422-4; ETSI EN 302 291-1;
ETSI EN 302 208; ETSI EN 301 357;
ETSI EN 303 609; ETSI EN 303 258;
ETSI EN 301 502;
ETSI EN 300 328; ETSI EN 301 893;
ETSI EN 302 502; ETSI EN 301 502;
ETSI EN 303 609; ETSI EN 301 511;
ETSI TS 151 010-1; ETSI EN 301 908-1;
ETSI EN 301 908-2 ;ETSI TS 134 121-1;
ETSI TS 134 121-2; ETSI EN 301 908-3;
ETSI EN 301 908-11; ETSI EN 301 908-13;
ETSI TS 136 521-1; ETSI TS 136 521-2;
ETSI EN 301 908-14; ETSI EN 301 908-15;
ETSI EN 301 908-25; ETSI TS 138 521-1;
ETSI TS 138 521-2; ETSI TS 138 521-3
Australia/New Zealand AS/NZS 4268
Australia AS/CA S042.1; AS/ACIF S042.3; AS/CA S042.4; AS/CA S042.5 | ||
| 4 | EN 62311; EN IEC 62311; BS EN IEC 62311; EN 62479; IEC 62479; BS EN 62479; EN 50385; BS EN 50385; EN 50383; BS EN 50383; EN 50364; BS EN 50364; IEC 62493; EN 62493; BS EN 62493; IEC 62233; EN 62233; BS EN 62233; EN 50663; BS EN 50663; EN 50665; BS EN 50665; SPR-002; AS/NZS 2772.2; IEC 62368-1; EN IEC 62368-1; AS/NZS 62368.1; UL 62368-1; CAN/CSA-C22.2 No. 62368-1; BS EN IEC 62368-1; UL 1310; UL 2089; ANSI/UL 2089; IEC 62680-1-2; EN IEC 62680-1-2; BS EN IEC 62680-1-2; IEC 62680-1-3; EN IEC 62680-1-3; BS EN IEC 62680-1-3; IEC 60335-1; EN 60335-1; BS EN 60335-1; AS/NZS 60335.1; UL 60335-1; CAN/CSA-C22.2 No. 60335-1; IEC 60335-2-2; EN 60335-2-2; BS EN 60335-2-2; AS/NZS 60335.2.2; IEC 60335-2-8; EN 60335-2-8; BS EN 60335-2-8; AS/NZS 60335.2.8; UL 60335-2-8; CAN/CSA-C22.2 No. 60335-2-8; IEC 60335-2-9; EN 60335-2-9; BS EN 60335-2-9; AS/NZS 60335.2.9; IEC 60335-2-14; EN 60335-2-14; BS EN 60335-2-14; AS/NZS 60335.2.14; IEC 60335-2-15; EN 60335-2-15; BS EN 60335-2-15; AS/NZS 60335.2.15; IEC 60335-2-23; EN 60335-2-23; BS EN 60335-2-23; AS/NZS 60335.2.23; IEC 60335-2-29; EN 60335-2-29; BS EN 60335-2-29; AS/NZS 60335.2.29; IEC 60335-2-32; EN 60335-2-32; BS EN 60335-2-32; AS/NZS 60335.2.32 | - | - |
| 5 | IEC 60335-2-45; EN 60335-2-45; BS EN 60335-2-45; AS/NZS 60335.2.45; IEC 60335-2-65; EN 60335-2-65; BS EN 60335-2-65; AS/NZS 60335.2.65; IEC 60335-2-80; EN 60335-2-80; BS EN 60335-2-80; AS/NZS 60335.2.80; UL 507; IEC 60335-2-98; EN 60335-2-98; BS EN 60335-2-98; AS/NZS 60335.2.98; UL 998; CSA C22.2 No. 104; UL 1017; CSA C22.2 No. 243; UL 1082; UL 499; UL 859; UL 1026; UL 1278; UL 1995; IEC 60598-1; EN IEC 60598-1; BS EN IEC 60598-1; AS/NZS 60598.1; UL 1598; CSA C22.2 No. 250.0; IEC 60598-2-1; EN IEC 60598-2-1; BS EN IEC 60598-2-1; AS/NZS 60598.2.1; IEC 60598-2-2; EN 60598-2-2; BS EN 60598-2-2; AS/NZS 60598.2.2; IEC 60598-2-4; EN 60598-2-4; BS EN 60598-2-4; AS/NZS 60598.2.4; UL 153; IEC 60598-2-5; EN 60598-2-5; BS EN 60598-2-5; AS/NZS 60598.2.5; IEC 60598-2-17; EN IEC 60598-2-17; BS EN IEC 60598-2-17; AS/NZS 60598.2.17; UL 1573; IEC 60598-2-20; EN 60598-2-20; BS EN 60598-2-20; AS/NZS 60598.2.20; IEC 62560; EN 62560; BS EN 62560; AS/NZS 62560 | Electrical appliances | - |
| 6 | UL 1576; CSA C22.2 No. 250.5; UL 1993; CSA C22.2 No. 1993; UL 588; ANSI/UL 588; IEC 61347-1; EN 61347-1; BS EN 61347-1; AS/NZS 61347.1; IEC 61347-2-12; EN 61347-2-12; BS EN 61347-2-12; AS/NZS 61347.2.12; IEC 61347-2-13; EN 61347-2-13; BS EN 61347-2-13; AS/NZS 61347.2.13; IEC 62841-1; EN 62841-1; BS EN 62841-1; UL 62841-1; CAN/CSA-C22.2 No. 62841-1; EN 15194; BS EN 15194; UL 2849; ANSI/UL 2849-2022; EN 17128; BS EN 17128; UL 2272; ANSI/CAN/UL 2272; EN 18031-1; BS EN 18031-1; EN 18031-2; BS EN 18031-2; EN 18031-3; BS EN 18031-3 | - | - |
| 7 | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; ANSI C63.17:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015 | - | to 40000 MHz |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SHENZHEN VOP TESTING TECHNOLOGY CO., LTD.
Shenzhen, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 22nd day of December 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 7579.01
Valid to November 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- Dongguan DN Testing Co.,DongguanA2LAShares 2 accredited test methodsANSI C63.4:2014EN 62311
- Dongguan New Testing Centre Co.,DongguanA2LAShares 2 accredited methods and materialsANSI C63.4:2014Electrical appliances
- Eurofins TA Technology (Shanghai) Co.,Shanghai 201201A2LAShares 2 accredited test methodsANSI C63.4:2014EN 62311
- Guangdong Zhonghan Testing Technology Co.,ShenzhenA2LAShares 2 accredited test methodsANSI C63.4:2014EN 62311
- SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen BranchShenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014EN 62311
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.