What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM D7759
ISO/IEC 17025:2017; ASTM D7759; AASHTO T312
ASTM D7759
Read from the scope as published by A2LA. Register refreshed 2026-11-06.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active6369.01
Accredited scope, certificate 6369.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ASTM D7759; AASHTO T312 | - | See scope document |
| 2 | AASHTO T312 | - | See scope document |
| 3 | AASHTO T312 | - | See scope document |
| 4 | ASTM D7759 | - | See scope document |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6369.01) 12/1/2025 Page 5 of 5
V. Time & Frequency
_________________
1 This laboratory offers commercial and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory
can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal
measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at
approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty
of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s
device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a
customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty
(CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration
and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual
allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this,
on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The locations of the laboratories that can perform the calibration are given by a three-letter code with valid to dates given
in the table below:
Location Code Valid to Dates
1 Triangle Drive, Research Triangle
Park, NC 27709
RDU 5/31/2027
4495 44 th Street SE, Suite A, Grand
Rapids, MI 49512
GRR 5/31/2027
5052 Commercial Circle, Suite A & B,
Concord, CA 94520
SFO 7/31/2026
850 E 73 rd Avenue, Unit 12, Denver,
CO 80229
DEN 7/31/2026
3580 Progress Drive, Unit O,
Bensalem, PA 19020
PHL 5/31/2027
6 In the statement of CMC, Wt is the representation of weight pounds or grams appropriate to the uncertainty statement.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable
of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
Please click here to return to page 1
Parameter/Equipment
Range
CMC2 (±)
Comments
Location5
Timers & Stopwatch3
(0.5 to 30) min
0.11 s
1025 Traceable
stopwatch
RDU
RPM3
(10 to 24 000) rpm
0.21 rpm
Extech tachometer
RDU | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
INSTROTEK, INC.
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined
scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 1st day of December 2025
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6369.01
Valid to: See Scope of Accreditation | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.