Registers refreshed 2026-11-08.See refresh dates
United States

InstroTek

5052 Commercial Circle, Suites A&B, 94520, Concord, CA, United States

Visit website
A2LA 6369.04ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
1
A2LA certificate
1
Sites in our directory
10
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM D7759

Read from the scope as published by A2LA. Register refreshed 2026-11-06.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

6369.04

View scope

Accredited scope, certificate 6369.04

LineMethodMatrixRange
1ISO/IEC 17025:2017; ASTM D7759; AASHTO T312-See scope document
2AASHTO T312-See scope document
3AASHTO T312-See scope document
4ASTM D7759-See scope document
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6369.01) 12/1/2025 Page 5 of 5 V. Time & Frequency _________________ 1 This laboratory offers commercial and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The locations of the laboratories that can perform the calibration are given by a three-letter code with valid to dates given in the table below: Location Code Valid to Dates 1 Triangle Drive, Research Triangle Park, NC 27709 RDU 5/31/2027 4495 44 th Street SE, Suite A, Grand Rapids, MI 49512 GRR 5/31/2027 5052 Commercial Circle, Suite A & B, Concord, CA 94520 SFO 7/31/2026 850 E 73 rd Avenue, Unit 12, Denver, CO 80229 DEN 7/31/2026 3580 Progress Drive, Unit O, Bensalem, PA 19020 PHL 5/31/2027 6 In the statement of CMC, Wt is the representation of weight pounds or grams appropriate to the uncertainty statement. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. Please click here to return to page 1 Parameter/Equipment Range CMC2 (±) Comments Location5 Timers & Stopwatch3 (0.5 to 30) min 0.11 s 1025 Traceable stopwatch RDU RPM3 (10 to 24 000) rpm 0.21 rpm Extech tachometer RDU
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited INSTROTEK, INC. for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 1st day of December 2025 _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6369.01 Valid to: See Scope of Accreditation

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

5052 Commercial Circle, Suites A&B, Concord, CA, 94520, US

37.97685, -122.03356

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.