Sushi TOWE Wireless Testing (Shenzhen) Co.,Ltd.
F 401 and F 101, Building E, Hongwei Industrial Zone, No. 6, Liuxian 3rd Road, Zone 70, Xingdong Community, Xin'an Street, Bao'an District, Shenzhen, People's Republic of China, Shenzhen, China
Visit website- Accredited standards
- 142
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 142 standard numbers and the 33 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI88
ETSI EN 125 144
ETSI EN 125 914
ETSI EN 134 114
ETSI EN 137 544
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 386
Show all 88
ETSI EN 300 440
ETSI EN 301 441
ETSI EN 301 442
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-4
ETSI EN 301 489-5
ETSI EN 301 489-6
ETSI EN 301 489-9
ETSI EN 301 489-12
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-20
ETSI EN 301 489-33
ETSI EN 301 489-50
ETSI EN 301 489-51
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 549
ETSI EN 301 681
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-11
ETSI EN 301 908-13
ETSI EN 301 908-14
ETSI EN 301 908-15
ETSI EN 301 908-24
ETSI EN 301 908-25
ETSI EN 302 065-1
ETSI EN 302 065-2
ETSI EN 302 065-3
ETSI EN 302 065-4
ETSI EN 302 065-5
ETSI EN 302 208
ETSI EN 302 502
ETSI EN 302 571
ETSI EN 302 574-2
ETSI EN 302 574-3
ETSI EN 303 345-1
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI EN 303 609
ETSI EN 303 687
ETSI EN 304 220-1
ETSI EN 304 220-2
ETSI ES 200 381-2
ETSI TS 102 230-1
ETSI TS 125 143
ETSI TS 134 108
ETSI TS 134 121-1
ETSI TS 134 121-2
ETSI TS 136 104
ETSI TS 136 141
ETSI TS 136 143
ETSI TS 136 508
ETSI TS 136 521-1
ETSI TS 136 521-2
ETSI TS 136 521-3
ETSI TS 138 101-1
ETSI TS 138 101-3
ETSI TS 138 104
ETSI TS 138 106
ETSI TS 138 114
ETSI TS 138 115-1
ETSI TS 138 141
ETSI TS 138 508-1
ETSI TS 138 508-2
ETSI TS 138 521-1
ETSI TS 138 521-3
ETSI TS 138 521-4
ETSI TS 138 522
ETSI TS 138 533
ETSI TS 151 010-1
ETSI TS 151 010-2
ETSI TS 151 026
EN13
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50332-1
EN 50332-2
EN 50360
EN 50364
EN 50383
EN 50384
EN 50385
EN 50563
EN 50564
EN 50566
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
IEC 61000 series12
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
AS/NZS IEC 61000.4.2probably the same standard; matched by number only
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
AS/NZS IEC 61000.4.3probably the same standard; matched by number only
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
AS/NZS IEC 61000.4.4probably the same standard; matched by number only
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+2 national
National versions in the same scope
AS IEC 61000.4.5probably the same standard; matched by number only
AS/NZS 61000.4.5probably the same standard; matched by number only
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+3 national
National versions in the same scope
AS IEC 61000.4.6probably the same standard; matched by number only
AS/NZS 61000.4.6probably the same standard; matched by number only
AS/NZS IEC 61000.4.6probably the same standard; matched by number only
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+1 national
National versions in the same scope
AS/NZS 61000.4.8probably the same standard; matched by number only
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national
National versions in the same scope
AS/NZS 61000.4.11probably the same standard; matched by number only
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environmentsExclusion+1 national
Limits written next to it
BS EN IEC 61000-6-1 (Excluding -20, 21, 22, 34)
National versions in the same scope
AS/NZS 61000.6.1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environmentsExclusion+1 national
Limits written next to it
BS EN IEC 61000-6-2 (Excluding -20, 21, 22, 34)
National versions in the same scope
AS/NZS 61000.6.2national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC8
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 62232
IEC 62301
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 63170
IEC 63195-1
CISPR5
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national
National versions in the same scope
AS/NZS CISPR 32identical to it
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC 61326 series5
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-4
EN 18031 series3
EN 18031-1
EN 18031-2
EN 18031-3
IEC 62209 series3
IEC 62209-1
IEC 62209-2
IEC 62209-3
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
FCC PART 15Radio Frequency Devices
RSS-102
RSS-GEN
3GPP TS 25.144; 3GPP TR 25.914; 3GPP TS 34.114; 3GPP TS 37.544; OMA Secure User Plan Location; OMA-ETS-MMS-INT; OMA-ETS-SUPL; OMA-ETS-SUPL-V2.0; OMA-ETS-LPPe-V1; GSMA TS.11; GSMA TS.40; GSMA TS.42; GSMA SGP.23; PTCRB NAPRD03; PTCRB PPMD; GCF-CC; ETSI TS 151 010-1; ETSI TS 151 010-2; ETSI TS 134 121-1; ETSI TS 134 121-2; ETSI TS 136 521-1; ETSI TS 136 521-2; ETSI TS 136 521-3; ETSI TS 138 101-1; ETSI TS 138 101-3; ETSI TS 138 521-1; ETSI TS 138 521-3; ETSI TS 138 521-4; ETSI TS 138 533; ETSI TS 134 108; ETSI TS 136 508; ETSI TS 138 508-1; ETSI TS 138 508-2; ETSI TS 138 522; ETSI TS 102 230-1; ETSI TS 136 141; ETSI TS 136 104; ETSI TS 138 141; ETSI TS 138 104; ETSI TS 151 026; ETSI TS 125 143; ETSI TS 136 143; ETSI TS 138 106; ETSI TS 138 114; ETSI TS 138 115-1; ETSI EN 301 511; ETSI EN 301 908-2; ETSI EN 301 908-1; ETSI EN 301 908-13; ETSI EN 125 144; ETSI EN 125 914; ETSI EN 134 114; ETSI EN 137 544; ETSI EN 301 908-25; ETSI EN 301 908-14; ETSI EN 301 908-24; ETSI EN 303 609; ETSI EN 301 908-11; ETSI EN 301 908-15; ETSI EN 301 441; ETSI EN 301 442; ETSI EN 302 574-2; ETSI EN 302 574-3; ETSI EN 301 681
3GPP TS 51.010-1; 3GPP TS 34.124; 3GPP TS 36.124; 3GPP TS 38.124; PTCRB PVG.04; PTCRB NAPRD03; PTCRB PPMD; GCF-CC; CTIA Certification Test Plan for Wireless Device Over-the-Air Performance 1; CTIA 01.20 Test Methodology SISO Anechoic Chamber; CTIA Certification /Wi-Fi Alliance Test Plan for RF Performance Evaluation of Wi-Fi Mobile Converged Devices; ETSI EN 301 908-2 Chapter 4.2.14, 4.2.15, 5.3.13, 5.3.14; ETSI EN 301 908-13 Chapter 4.2.13, 4.2.14, 5.3.12, 5.3.13; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 330; ETSI EN 300 440; ETSI EN 302 502; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 303 345-1; ETSI EN 302 571; ETSI EN 303 687; ETSI EN 302 065-1; ETSI EN 302 065-2; ETSI EN 302 065-3; ETSI EN 302 065-4; ETSI EN 302 065-5; ETSI EN 304 220-1; ETSI EN 304 220-2; ETSI EN 302 208; IEC 61000-3-2; EN 61000-3-2; BS EN 61000-3-2; EN IEC 61000-3-2; BS EN IEC 61000-3-2; AS/NZS 61000.3.2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; AS/NZS 61000.3.3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; AS/NZS IEC 61000.4.2
IEC 61000-4-3; EN 61000-4-3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3; AS/NZS IEC 61000.4.3; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; AS/NZS IEC 61000.4.4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; AS/NZS 61000.4.5; AS IEC 61000.4.5; IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; AS/NZS 61000.4.6; AS IEC 61000.4.6; EN IEC 61000-4-6; BS EN IEC 61000-4-6; AS/NZS IEC 61000.4.6; IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8; AS/NZS 61000.4.8; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN 61000-4-11; BS EN IEC 61000-4-11; AS/NZS 61000.4.11; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; ETSI EN 301 489-33; ETSI EN 301 489-4; ETSI EN 301 489-5; ETSI EN 301 489-6; ETSI EN 301 489-9; ETSI EN 301 489-12; ETSI EN 301 489-20; ETSI EN 301 489-50; ETSI EN 301 489-51; ETSI EN 300 386; ETSI TS 138 114; CISPR 35; EN 55035; BS EN 55035; AS/NZS CISPR 32; EN 50130-4; BS EN 50130-4; EN IEC 55014-1; EN IEC 55014-2; BS EN IEC 55014-1; BS EN IEC 55014-2; AS/NZS CISPR 14.1; CISPR 14-1; CISPR 14-2
RSS-102; RSS-102.SAR.MEAS; KDB 865664 D01; KDB 941225 D01; KDB 941225 D05; KDB 941225 D06; KDB 941225 D07; KDB 616217 D04; KDB 643646 D01; KDB 447498 D01; Australian Communications Authority “Radiocommunications (Electromagnetic Radiation – Human Exposure) Standard” AS/NZS 2772.2; Article 14-2 of the Ordinance Regulating Radio Equipment Annex 79 of MIC Notification No.88; RSS-102.NS.MEAS; IEC/IEEE 63195-1; BS IEC 63195-1; IEC TR 63170; PD IEC 63170; RSS-102; RSS-102.IPD.MEAS; CFR 47, FCC part 20; ANSI C 63.19 (2011, 2019); RSS-HAC; EN 301 549; ETSI ES 200 381-2; ANSI/TIA-5050; IEC 62368-1; EN 62368-1; AS/NZS 62368.1; CAN/CSA-C22.2 No. 62368-1; UL 62368-1; EN IEC 62368-1; BS EN IEC 62368-1; EN 50332-1; BS EN 50332-1; EN 50332-2; BS EN 50332-2; IEC 62301; EN 50564; BS EN 50564; EN 50563; BS EN 50563
RSS-GEN; RSS-111; RSS-130; RSS-132; RSS-133; RSS-139; RSS-140; RSS-170; RSS-191; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199; RSS-210; RSS-216; RSS 220; RSS-247 (with and without DFS); RSS-248; Article 2, Paragraph 1 of the Ordinance: Item 2(3); Item 11-3; Item 11-7; Item 11-19; Item 11-19-2; Item 11-19-3; Item 11-21; Item 11-30; Item 11-34; Item 19; Item 19-2; Item 19-2-2; Item 19-2-3; Item 19-3; Item 19-11; Item 21; Item 21-3; Item 22; Item 54; Item 54-2; Item 54-4; Item 54-6; Item 79; Item 80; Item 81; Article 3-9; Article 17-32; Article 34; AS/NZS 4268; AS/CA S042.1; AS/CA S042.4; AS/CA S042.5; EN 62209-1; BS EN 62209-1; IEC 62209-1; EN 62209-2; BS EN 62209-2; IEC 62209-2; IEC 62209-3; EN IEC 62209-3; BS EN IEC 62209-3; EN 62311; BS EN 62311; IEC 62311; EN IEC 62311; BS EN IEC 62311; EN 62479; BS EN 62479; IEC 62479; EN 50360; BS EN 50360; EN 50566; BS EN 50566; EN 50385; BS EN 50385; EN 50383; EN 62232; IEC 62232; BS EN 62232; EN 50364; BS EN 50364; EN 50663; BS EN 50663; EN 50665; BS EN 50665; EN 50384; BS EN 50384; IEEE Std. 1528; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; BS EN IEC/IEEE 62209-1528; ANSI/IEEE Std. C95.1
EN IEC 61326-1; IEC 61326-1; BS EN IEC 61326-1; EN IEC 61326-2-1; IEC 61326-2-1; BS EN IEC 61326-2-1; EN IEC 61326-2-2; IEC 61326-2-2; BS EN IEC 61326-2-2; EN IEC 61326-2-3; IEC 61326-2-3; BS EN IEC 61326-2-3; EN IEC 61326-2-4; IEC 61326-2-4; BS EN IEC 61326-2-4; EN IEC 61000-6-1; BS EN IEC 61000-6-1; EN60601-1-2; IEC 60601-1-2; BS EN 60601-1-2; IEC 61000-6-1; AS/NZS 61000.6.1; EN IEC 61000-6-2; BS EN IEC 61000-6-2; IEC 61000-6-2; AS/NZS 61000.6.2; EN IEC 61000-6-4; BS EN IEC 61000-6-4; IEC 61000-6-4; AS 61000.6.4; CFR 47, FCC Part 15 Subpart B; ANSI C63.4; ICES-003; ICES-005; ICES-Gen; EN 55032; BS EN 55032; CISPR 32; FCC Part 18; MP-5:1986; ICES-001; VCCI-CISPR 32:2016; CISPR 11; AS CISPR 11; EN 55011; BS EN 55011; J55011; J55014-1; J55032; FCC CFR 47, FCC Part 15 Subpart C; ANSI C63.10-2013; ANSI C63.10-2020/Cor 1-2023; CFR 47, FCC Part 15 Subpart E; KDB 905462 D02 (v02); CFR 47, FCC Part 15 Subpart F; CFR 47, FCC Parts 20; 22; 24; 25; 27; 30; 90; 95; 96; 97; 101; ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015; KDB 971168; WINFF & CBRS WINNF-TS-0122 CBRS CBSD Test Specification; ONGO-TS-9001 Certification Test Plan
EN 18031-1; EN 18031-2; EN 18031-3; ANSI C63.4-2014; FCC MP-5:1986; ANSI C63.10-2013; ANSI C63.10-2020; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26-2015
ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26-2015; IEEE Std 1528-2013; ANSI C63.19:2011
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
10 lines
ISO/IEC 17025
Active7088.01
The scope document we hold says it is valid until 2027-08-31.
Labs with overlapping accredited scope in China
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 2 accredited test methodsANSI/TIA-603-EEN 300 328
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 2 accredited test methodsRSS-102RSS-GEN
- Guangdong Global Testing Technology Co.,DongguanA2LAShares 2 accredited test methodsANSI C63.4-2014ANSI/TIA-603-E
- Intertek Testing Services (Shanghai FTZ) Co.,ShanghaiA2LAShares 2 accredited test methodsANSI/TIA-603-ERSS-GEN
- MRT Technology (Shenzhen) Co.,Shenzhen, GuangdongA2LAShares 2 accredited test methodsANSI/TIA-603-ERSS-GEN
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.